Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | Not Admitted-Finance NO 138 C O PANDIAN ROJA STREET ARUNACHALAM NAGAR THABALTHANTHI NAGAR ANAIYUR MADURAI 625 017 | MADURAI | MADURAI | TAMIL NADU | 625017 | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹50 L
EMD Value
₹50,000
Closing Date
19 Mar 2025, 3:00 pmClosed
EXECUTIVE OFFICER
Executive Officer Thiruppuvanam Town Panchayat Sivagangai District
GENERALFUND2024-2025 Construction of New Office Building First Floor at Ward No.05 Madurai Mandabam Main Road S.F No.43/8B1 in ThiruppuvanamTown Panchayat
2025_DTP_529487_1
RocNo.380/2024/A1
Open Tender
Civil Works
Works
180 days
Thiruppuvanam
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹50,000
Thiruppuvanam Town Panchayat
10 May 2025
3 Mar 2025
19 Mar 2025
3 Mar 2025
19 Mar 2025
3 Mar 2025
12 Mar 2025
Amount
OFFICE BUIDLING
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. - For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - first floor
Supply and fabrication of steel required for all RCC items of works involved in the schedule, cost of steel at site fabrication, labour charges for cleaning the rods straightening, cutting, bending, tying grills, including overlapping to the required length whenever necessary and placing the reinforcement in position as as per design given and specified in the drawings, including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc complete as per standard specification
Brick work in CM 1:5 (one cement & Five sand) using II class ground moulded bricks of size 9"X43/8"X 23/4" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost) - FIRST FLOOR
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding, grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three sand) 10mm thick including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering with cement mortar 1:5 (One cement and five sand) 12mm thick in all floors including cost and conveyance of all materials to site etc,complete as per standard specifications
Painting two coats of newly plastered wall surface with ready mixed exterior emulsion paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification.
Paving the floor with descrgned coloured vitrified tiles of size 600 x 600 x 8mm of best quality and approved variety complying / confirming ISI specification land over cement mortar 1:3 (one cement and three sand) 20mm thick and pomted with same coloured cement neatly etc., complete.
Supplying and fixing over the floors best quality of scratch ceramic tiles of 30 c.m x 30c.m x 6mm size of approved colour laying with cement mortor 1:3 mix pointing the joints with colour pigments etc. Complete.
Dadooing the walls with glazed tiles of 30 c.m x 20 c.m 6mm size laid in cement mortor 1:2 mix 10mm thick and pointing with 0.40 kg white cement per m2 etc.
B) Supplying and fixing in position colour glazed EUROPEAN WATER CLOSET with 'p' or 'S' trap and double flapped seat cover, 12.50 litres capacity P.V.C low level FLUSING TANK including all internal fittings fixed on C.I brackets,12mm PVC or brass niple, chromium plated brown headted stopcock, 12mm nylon connection with necessary teakwood plugs,clams, screws to the portion coming with walls and floors , including dismantling masonary and and redoing the same to the original condition .
Weathering Course with broken brick jelly 20mm size pure slacked lime over R.C.C. roof slab the preparation of 32:12.5 for required depth and slope etc. complete.
Finishing the top of roof with one course of machine pressed tiles 23 C.m x 23 C.m x 2 C.m size using cement mortor 1:3 mix mixed with 2% by weight of Crude Oil and pointing with Cement Mortor 1:3 mix Cost of all materials and labour charges and brick jelly concrete etc., complete as per standard specifications.
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVCrigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wallwith 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealedlight point / fan point (for electronic regulator)SD 24
Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from terminals to the fitting with tube SD 89
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18") SD 106
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point SD 38
Supply and fixing of TNEB METER BOARD suitable for 32A single phase service connectionwith 32A fuse unit 500V 32 A neutral link and earth link (1"x1/8" Copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bold and nuts for fixingthe TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire form EB meter to FUSE ONLY (SD-121)
Supply and delivery of the following pipe and specials for the erection of pump sets with ISI specification as directed by thedepartmental officers including cost and conveyence of the same etc complete as per standard specification. 25mm Dia PVC Bend
32mm PVC Tee
32mm PVC bend
32-25 mm reducer
25-20 mm reducer
20mm Tap
25mm dia PVC pipe 10kg/cm1
32mm dia PVC pipe 10kg/cm2
Supply and delivery of PVC Tank approved colour and quality as directed by the departmental officers including cost and conveyence of all meterials to work site etc complete as per TWAD SS (1000 ltr)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .