Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹21.7 L+₹59,786 (2.84%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L2 | Rejected-Finance Not Lowest Tenderer | |
| 3 | L3₹22.1 L+₹99,126 (4.70%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not Lowest Tenderer | |
| 4 | L4₹23.0 L+₹1.9 L (9.17%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Tenderer | |
| 5 | L5₹28.6 L+₹7.5 L (35.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Tenderer |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Sept 2022, 6:00 pmClosed
GE South Delhi Cantt 10
Garrison Engineer South Delhi Cantt 110010
REPAIR/MAINT OF SUMMER/WINTER APPLIANCES AND OLD UNSV WIRING ALONGWITH FITTING AND FIXTURES AT ANUJ VIHAR, VIKRAM VIHAR, SHANKAR VIHAR UNDER AGE E/M (S) OF GE (SOUTH) DELHI CANTT-10
2022_MES_547290_1
GE/DS-62/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹80,000
Yes
18 Oct 2022
24 Aug 2022
23 Sept 2022
24 Aug 2022
21 Sept 2022
7 Sept 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed by Engr-in-Charge.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engr-in-Charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per item No 2 above but One 3 pin socket outlet, 5/6 Amps, or independent board, with cables 1.5 sq. mm size with through existing concealed PVC/MS conduit complete.
All as per item No 2 above but 5 Amp socket outlet on same board complete.
All as per Item No 2above but for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit complete.
All as Item No 2 above but for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing with through existing concealed PVC/MS conduit complete.
S&F of switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engr-in-Charge.
S&F of switch piano flush type 5/6 Amps SP two way complete all as specified and directed by Engr-in-Charge.
S&F bell push, flush type 5/6 Amps complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type 15/16 Amps SP one way complete all as specified and directed by Engr-in-Charge.
S&F universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engr-in-Charge.
S&F 0-4 step type electronic regulators for ceiling fan 1200/1400mm sweep, 240V complete all as specified and directed by Engr-in-Charge.
S&F switch modular type, 1 way 6A, 1module complete all as specified and directed by Engr-in-Charge.
S&F Modular Socket, 6A - 2/3 pin 2 module complete all as specified and directed by Engr-in-Charge.
S&F switch modular type 1way 16A, 1 module complete all as specified and directed by Engr-in-Charge.
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed by Engr-in-Charge.
S&F Modular Bell push 6A 1 module complete all as specified and directed by Engr-in-Charge.
S&F stepped type electronic fan regulator modular type, 2 module complete all as specified and directed by Engr-in-Charge.
S&F lamp holder Angle/Batten Type bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Engr-in-Charge.
S&F in replacement Stylo Wall Light, Decorative wall mounting, Champagne gold finish fixture with plastic body suitable for Led Lamp upto 15 Watt complete with all connections complete all as specified and directed by Engr-in-Charge.
S&F in replacement of electric bell (Buzzer) any type complete with including fliexble wire in complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Electric bell ding dong any type complete with including fliexble wire in complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engr-in-Charge.
S&F wal mounted LED Integrated batten T5 20Watt-4ft white, 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 36/40Watt FTL fitting any type complete all as specified and directed by Engr-in-Charge.
S&F wal mounted LED Integrated batten T5 10Watt -2ft white, 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 18/14 watt FTL fitting any type, complete all as specified and directed by Engr-in-Charge.
S&F surface mounting Round/ Square shaped LED downlighter 6 Watt any type complete with including new fliexble wire as required on site including taking down of old unsv existing ceiling light fitting any type complete all as specified and directed by Engr-in-Charge.
S&F LED 10 watt white Bulk head any type complete with including new fliexble wire as required on site and including taking down of old unsv existing light fitting of any type complete all as specified and directed by Engr-in-Charge.
S&F in replacement of VTPN distribution board 4 way double door, vertical type for fixing MCCB up to 250 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as specified and directed by Engr-in-Charge. (Make : Legrand Cat No. 5077 47 or equivalent in L&T/Havells/Indoasian/ Siemens as approved)
S&F in replacement of VTPN distribution board 8 way double door, vertical type for fixing MCCB up to 250 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as specified and directed by Engr-in-Charge. (Make : Legrand Cat No. 5077 47 or equivalent in L&T/Havells/ Indoasian/Siemens as approved)
S&F in replacement of MCCB 3 Pole 415V, 'C' series 200 Amps with breaking capacity 36 KA including providing new lugs & thimbles of required size complete as per site requirement all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 3 Pole 415V, 'C' series 160 Amps with breaking capacity 36 KA including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB TP 3 Pole from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-8 Way, 240V with 200 Amp rated busbar as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-12 Way, 240V with 200 Amp rated busbar as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-16 Way, 240V with 200 Amp rated busbar as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SPN 63 Amps 240 volts, 'C' Series 10 KA or of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SPN 40 Amps 240 volts, 'C' Series 10 KA or of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SP 63 AMPs C curve complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SP 40 AMPs C curve complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SP 6 to 32 AMPs C curve complete all as specified and directed by Engr-in-Charge.
S&F in replacement Sheet metal encl with metal clad plug & socket and MCB SP 20Amps, 240 V complete all as specified and directed by Engr-in-Charge.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 10 Sqmm in 2 runs and 10Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and directed by Engr-in-Charge.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and directed by Engr-in-Charge.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and directed by Engr-in-Charge. Notes for Srl item Nos. 43 to 45 :- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L for earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI wire 4 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 15 mm dia upto 7.5 M, GI watering pipe 20 mm dia medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 5 of SSR Part I, including earth test point upto panel board, all as specified or indicated including testing on completion complete all as specified and directed by Engr-in-Charge.
Taking down of ceiling fan/ exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation with required cable and testing complete all as specified and directed by Engr-in-Charge. Note:- Rewinding will be measured and paid under respective item of this Schedule.
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush and Shaft where ever required complete all as specified and directed by Engr-in-Charge.
M&L for Rewinding of Exhaust Fan & Wall mounted fan upto 450 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush & shaft where ever required complete all as specified and directed by Engr-in-Charge.
S&F in replacement ceiling fan/ Exhaust fan Ball bearing of suitable size & model (as per sample) complete all as specified and directed by Engr-in-Charge. Make:- NBC/ SKF
S&F in replacement of fan condenser 2.5 Mfd complete all as specified and directed by Engr-in-Charge. Make :- Epcos/Tibcon/Havells
S&F in replacement of fan condenser 3.15 Mfd complete all as specified and directed by Engr-in-Charge. Make :- Epcos/Tibcon/Havells
M&L for replacement of exhaust fan blades for size upto 450 mm sweep as per sample complete all as specified and directed by Engr-in-Charge.
M&L for replacement of MS louvers suitable for exhaust fan of sizeupto 450 mm sweep as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement ceiling fan holder hook with rubber washer suitable for size 1200/1400 mm ceiling fan as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC canopy for ceiling fan of size 1200/1400 mm as per sample complete all as specified and directed by Engr-in-Charge.
Taking down geyser 25/35/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and directed by Engr-in-Charge.
S&F in replacement heating element 1.5 KW for any make of geyser of 25/35 litres capacity as per sample complete all as specified and directed by Engr-in-Charge. Make : Micronking/Theeta/Standard
S&F in replacement heating element 2 KW for any make of geyser of 50 litres capacity as per sample complete all as specified and directed by Engr-in-Charge. Make : Micronking/Theeta/Standard
S&F in replacement thermostat (9/11 inch Long) for 25/35/50 ltrs capacity geysers complete all as specified and directed by Engr-in-Charge. Make : Micronking/Theeta/ Standard
S&F in replacement indicating lamp round / flat type as required for geyser 25/35/ 50 litres capacity as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement safety valve ISI marked for geyser 25/35/50 litres capacity as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement safety plug for geyser 25/35/50 litres capacity as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC connection with brass nipple 15 mm x 450 mm long for hot water for geyser 25/35/50 ltrs capacity as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat, including rubber gasket for bajaj Caldia model geyser of 25 litres cap as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 35 litres cap as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 50 litres cap as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement inner stainless tank suitable for 25 Ltr storage water heater complete all as specified and directed by Engr-in-Charge.
S&F in replacement inner stainless tank suitable for 35 / 50 Ltr storage water heater complete all as specified and directed by Engr-in-Charge.
S&F FR PVC Sheathed Round , Copper conductor (Flexible) industrial cable, 1100 Volts, conforming to IS: 694 of size 2.5 Sqmm 3 core for connecting geyser, including taking down old unserviceable cable complete all as specified and directed by Engr-in-Charge.
S&F in replacement Rubber gasket for Water heater storage type of any capacity fixed and suitable as per the existing, complete all as specified and directed by Engr-in-Charge.
S&F in replacement MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and directed by Engr-in-Charge.
S&F in replacement of building security light fitting 45W LED 5000K new Powder coated pressure die cast aluminium compact LED Street light suitable for pole dia 40 mm of bracket duly fixed with clamps, nut, bolts & washers etc complete all as specified and directed by Engr-in-Charge.
Notes for BoQ:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Chaudhary Constructions
verma enterprises
M/s S.G. BUILDERS
Grid Infratech Pvt Ltd
S.R. Constructions
DHARAMRAJ BUILDERS & ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .