Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H1₹7.9 LAdmitted-Finance | H1 | Admitted-Finance | |
| 2 | H2₹7.5 L−₹42,550 (5.38%)Admitted-Finance | H2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical disqualified as per attached report | |
| 4 | Rejected-Technical | - | Rejected-Technical disqualified as per attached report |
| Sl No | Description | Qty | Unit | UNIQUE ASSOCIATES H1 | A R CONSTRUCTION SERVICES AND SUPPLIERS H2 |
|---|---|---|---|---|---|
| 1.00 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes | 1,809 | Kg. | 125 ₹2,26,125 | 105 ₹1,89,945 Lowest |
| 2.00 | Design, manufacture, Supply and Installation of assembly of extruded cellular / x structure UV protected polycarbonate panels incorporated into a complete system. Co-extruded UV-protected polycarbonate panel system of minimum 16mm thick panel of 900-1200 mm width to ensure best performance for wind uplift, vibration, oil canning, and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with grip on locking mechanism and will be secured on MS Structure with self drilling screws to ensure a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Polycarbonate panels also shall not have Yellowness Index as per ASTM D1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G155. The polycarbonate panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G155. Panel shall be with additional Endcap /AluminumU/ FProfile/ GlazingBar (mill finish) for ends as required. The panel shall be fixed over MS structural steel /MS purlin (to be paid separately) conforming to the detailed technical specifications as per approved architectural drawings. | 152 | Sqm | 3,600 ₹5,47,200 Lowest | 3,600 ₹5,47,200 Lowest |
| 3.00 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work | 70 | Sqm | 241 ₹16,870 | 150 ₹10,500 Lowest |
Tender Value
₹8.9 L
EMD Value
₹17,800
Closing Date
11 Sept 2025, 5:00 pmClosed
SE and PIC
IIT Indore
Repairing and replacement of roof sheet of damaged parking at KRC at IIT Indore
2025_IITI_876122_1
IITI/IDO/Parking/NIT-7/2024-25
Open Tender
Civil Works - Others
Item Rate
IIT indore
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹17,800
3 Oct 2025
4 Sept 2025
12 Sept 2025
4 Sept 2025
11 Sept 2025
4 Sept 2025
Amount
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Design, manufacture, Supply and Installation of assembly of extruded cellular / x structure UV protected polycarbonate panels incorporated into a complete system. Co-extruded UV-protected polycarbonate panel system of minimum 16mm thick panel of 900-1200 mm width to ensure best performance for wind uplift, vibration, oil canning, and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with grip on locking mechanism and will be secured on MS Structure with self drilling screws to ensure a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Polycarbonate panels also shall not have Yellowness Index as per ASTM D1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G155. The polycarbonate panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G155. Panel shall be with additional Endcap /AluminumU/ FProfile/ GlazingBar (mill finish) for ends as required. The panel shall be fixed over MS structural steel /MS purlin (to be paid separately) conforming to the detailed technical specifications as per approved architectural drawings.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
A R CONSTRUCTION SERVICES AND SUPPLIERS (BID ID -3280560)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .