Construction of a sewing workshop cum warehouse in Mouza Garhsisai, Vidyapatinagar Block, Samastipur District. (Police Station No. 98, Account No. 1473, Khasra No. 2830, Area 14.9D)
143270
GR-01/Re NIT-04/2026-27/LAEO/W.D-01 SAMASTIPUR
Open Tender
CIVIL
Samastipur
• Name and Address of Agency with registration No.
• Earnest Money
• PAN NO.
• GST Registration
• Character Certificate
• Affidavit/self declaration of investment of 25% of bid value
• Existing commitments
• Affidavit
• Experience As Per Nit
• If any other document as per NIT
CIVIL
PERCENTAGE
L1
1
10 documents required · 10 mandatory
₹10,000
Processing Fee: 5900
₹2.4 L
13 Nov 2026
13 Nov 2026
26 Nov 2026
18 Nov 2026
24 Nov 2026
18 Nov 2026
120 days
GOVERNMENT OF BIHAR
योजना एवं विकास विभाग
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
Estimated Cost : Rs.
स्थानीय क्षेत्र अभियंत्रण संगठन कार्य प्रमंडल 1- समस्तीपुर
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
1 CIVIL WORK IN BUILDING
3 SEPTIC TANK AND SOAKPIT
5 ELECTRIFICATION (LS)
6 FIRE FIGHTING
A TOTAL (SL. NO. 1 to 8) (A)
B Contingency 1% Upto 1 cr 100000
C Contingency 0.5% of beyond 1 cr
D Consultancy fee 1.75% of (A)
E Add Cost of Soil Test 60000
F Add cost of Sign Board/Shilapat 10000
TOTAL ESTIMATED COST (A+B+C+D+E)
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
THE RATES OF ITEMS ARE BASED ON CURRENT S.O.R. OF BUILDING CONSTRUCTION DEPARTEMENT -2022, GOVT. OF BIHAR .
S.NO. ITEM NO. DESCRIPTION QUANTITY RATE UNIT AMOUNT
NOS LENGTH WIDTH HEIGHT TOTAL
1 2.33 Cleaning grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 357.2 100SQM
2 A Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). 902.6 METRE
20.2.1 300 mm dia piles
B 63 CM (25) UNDER -REAM Making 63 cm (25) dia under ream at required with hand auger of approved quality in ordinary soil (vide classification of soil ifem - A) true to plumb and without eccentri city in my stage of opration and disposal of the excavated earth up to 50 mts lead in eluding all lifts , all complete as per approved design and direction of (E/l) 190.2 EACH
3 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 360.7 CUM
PILE CAP 3.5 3.5 2.5
4 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 287.3 CUM
Stair 1 5 15 0.5
Landing Platform 1 5 10.83 0.5
Loading Unloading Deck 1 14 16 0.5
Guard Room 1 8 6 0.5
DEDUCTION π (6")2 6"
PILLING 0.25 0.5
TOTAL CFT AFTER DEDUCT
5 11.72 Providing designation 100 A one brick flat soling joints filled with local sqm 283.30 sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 283.3 SQM
Landing Platform
Loading Unloading Deck
DEDUCTION π/4 (6")2
TOTAL SFT AFTER DEDUCT
6 4.1.2 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 4420.8 CUM
1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Guard room floor 1 8 5 0.33
Guard room Plinth beam 1 26 0.83 0.33
DEDUCTION π/4 (6")2 3"
PILLING 0.25 0.33
TOTAL CFT AFTER DEDUCT
7 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level 4688.3 CUM
1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
GRADE BEAM 0.83
Guard room G beam 0.83
8 5.2.2 Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. 5670 CUM
1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
9 6.1.12C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1.:4 (1 cement: 4 coarse sand ) 5116.3 CUM
TOTAL DEDUCTION
10 6.1.12C +6.3C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1.:4 (1 cement: 4 coarse sand ) Extra tor Brick work in superstructure above plinth level upto floor V cum 5958.5 CUM
Guard room 1 26 0.83 9
Loading Unloading Deck 1
Front and Back Triangle Section 1 42 0.83 6
DEDUCTION (DOORS, WINDOW, VENTILATOR & COLUMN)
11 5.33A.2.2 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc. 5677.2 CUM
Lintel Beam 10' 2 290 0.83 0.83
Lintel Beam 5' 1 0.33
Roof Slab Mezzanine 1 32 22.5 0.42
Roof Slab Guard Room 2 8 6 0.42
Lintel Beam Gurard Room 2 26 0.83 0.5
Top Beam G. room 2 26 1 1
Window Slab 28 4 3 0.25
12 5.9 BCD SOR Centring and shuttering including strutting,propping etc. and removal of form for.
5.9.1 Foundations, footings, bases of columns etc. for mass concrete. 211.6 SQM
5.9.5 Lintels, beams, plinth bams, griders, bressumers and contilevers. 404.7 SQM
Window sides 0.25
5.9.6 Columns,Pillars, Piers, Abutments, Posts and Struts. 494.4 SQM
5.9.3 Suspended floors, roofs, landings, balcnies and access platform. 437.5 SQM
Gurad Room Slab 2
TOTAL SQM total RCC Work in Cum cum
13 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete RF @ 150kg/cum Kg
5.22.7A Thermo-Mechanically Treated bars TMTC-500-8mm dia. 94.5 KG 0.22
5.22.7B Thermo-Mechanically Treated bars TMTC-500-10mm dia. 92.6 KG 0.3
5.22.7C Thermo-Mechanically Treated bars TMTC-500-12mm dia. 90.8 KG 0.2
5.22.7D Thermo-Mechanically Treated bars TMTC-500-16mm dia. 91.7 KG 0.18
5.22.7E Thermo-Mechanically Treated bars TMTC-500-20mm dia. 91.7 KG 0.1
Total Reinforcement KG
14 10.17 Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete. 174.6 EACH
15 10.5.2 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer 3467.9 SQM
Total Area inclusive of doors, RS and CG is
16 13.24.2 6 mm cement plaster to ceiling of mix : 1:4(1 cement: 4 coarse sand) 125.6 SQM
Mezzanine floor bottom 1 32 22.5
Guard Room 1 8 6
17 13.11.2 Cement plaster in course sand 152.9 SQM
12 mm cement plaster of mix:
1:4(1 cement :4 coarse sand)
Total Running Feet 1 538 9
TOTAL AREA AFTER DEDUCT
18 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 105.4 SQM
SUM OF SL NO 16+ SL NO 17
19 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exterior using Primer as per manufacturers specifications. 117.3 SQM
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm.
SAME STY SL NO. 19
21 11.41.2 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete. 1638.8 SQM
Size of Tile 60x60 cm
Mezzanine Floor 32 22.5
Ground Floor 10 15
Operational Area 75 36
22 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 795 SQM
23 10.32.1 Steel work in welded builtup section do all complete job for stairs
24 10.36 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). 546.8 KG
Outer Railing 1 51 3.5
MEZZANINE Railing 1 32 5
Steel Stair Railing 4 12 3.5
26 9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 144.5 KG
Fixed to steel windows by welding
Window 28 4 4.5
27 13.81.3 Applying priming coat: 118.1 SQM
With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
13.82.1 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:
New steel work (two or more coats)
AREA VIDE BOTH SIDE (ITEM NO 25+26)
28 10.16.2 Steel work in built up tubular trusses including cutting, hoisting,, fixing in position and applying a priming coar of approved steel primer, welded and bolted including special shaped washers etc. complete: 137.9 KG
Hot finished seamless type tubes
Item Nos Length Unit Wt
End Ridge 2 16.62
Truss (Standard Commercial Grade) 11 600
30 12.1.1 Providing corrugated G.S. sheet roofing fixed with G.I.J. or hooks, bolts and nuts 8 mm diameter with bitumen and G. I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (upto a pitch of 60°) excluding the cost or purlins, rafters and trusses. 1792.3 SQM
1.00 mm thick with zinc coating not less than 275 gm/mz
31 12.51.6 Providing Gutter 600 mm overall girth for water
32 26.23.1 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of mainT runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 1812.4 SQM
With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
34 26A.7 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: 4474.2 SQM
FRONT FACE 0.5 34 6
35 CARRIAGE OF MATERIAL:-
A BRICKS- 1246.1 /1000
B COARSE SAND- 2486.15 CUM
C LOCAL SAND - 317.14 CUM
D STONE CHIPS- 2711.98 CUM
Add Different Cost-
A BRICKS- 281.2 /1000
B CEMENT 268.03 MT
Extra cost of Royalty 73.59 /1000
1 Bricks 133.79 CUM
2 Coarse Sand 468.28 CUM
3 Stone Chips C 130 50
I TOTAL (A+B) 25 5
II PROVIDING 18% GST IN PLACE OF 12% GST (5.36% OF TOTAL A+B) 8 6
III Seigniorage Fee:- Net Area for Roads sqft
(A).Local sand- 14.19 M³
(B).Coarse sand- 27.58 M³
(C).Stone chips- 94.54 M³
TOTAL (I+II+III)
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
AUDITORIUM HALL
Sl. No. Item Of Work Quantity Unit Cement in M.T Local Sand in M3 Coarse Sand in M3 Stone Chips M3 Bricks in Nos
1 Local Sand Filling M3
2 B/F soling M2
7 Brick Work M3
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
THE RATES OF ITEMS ARE BASED ON CURRENT S.O.R. OF BUILDING CONSTRUCTION DEPARTEMENT -2022, GOVT. OF BIHAR .
SL. NO. CODE NO. QUANTITY RATE UNIT AMOUNT
DESCRIPTION NOS LENGTH WIDTH HEIGHT TOTAL
1 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 287.3 CUM
Paver Block Area 2000 0.25
2 16.78.2 Providing GSB with material conforming to Grade II as per the directions of EIC do all complete job 1239.4 CUM
10.79.1 Providing Paver Block 80 mm thick M35 Grade Concrete 956.4 SQM
4 CARRIAGE OF MATERIAL:-
C LOCAL SAND - CUM
D STONE CHIPS- CUM
Difference of cost of royalty
STONE CHIPS- cum
II PROVIDING 18% GST IN PLACE OF 12% GST (5.36% OF TOTAL) 28493.18
III Seigniorage Fee:-
(A).Local sand- M³
(C).Stone chips- M³
TOTAL (I+II+III)-
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
R.C.C DRAIN WORK
Material Statement
Sl. No. Item Of Work Quantity Unit Cement in M.T Local Sand in M3 Coarse Sand in M3 Stone Chips M3 Bricks in Nos
1 Local Sand Filling M3
2 B/F soling M2
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
THE RATES OF ITEMS ARE BASED ON CURRENT S.O.R. OF BUILDING CONSTRUCTION DEPARTEMENT -2022, GOVT. OF BIHAR .
SL. NO. CODE NO. BOUNDARY WORK QUANTITY RATE UNIT AMOUNT
DESCRIPTION NOS LENGTH WIDTH HEIGHT TOTAL
1 A Making 25 cm (10") dia bore up to 4 mtr depth below ground with hand auger of approved quality in ordinary soi! (vide classification of soil item A ) true to plumb and without eccentri city in any stage of operation and disposal of the excavated earth up to 50 mtr , Lead in eluding all lifts , all complete as per approved disign and direction of E/l Details of cost for 4 piles of 4 m= 16 mtrs depth ) 178.3 METRE
20.3A.1 25 cm dia piles
B 63 CM (25) UNDER -REAM Making 63 cm (25) dia under ream at required with hand auger of approved quality in ordinary soil (vide classification of soil ifem - A) true to plumb and without eccentri city in my stage of opration and disposal of the excavated earth up to 50 mts lead in eluding all lifts , all complete as per approved design and direction of (E/l) 190.2 EACH
2 2.8 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 360.7 CUM
PILE CAP 9 3 3 2.5
3 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 287.3 CUM
PILE CAP 9 3 3 0.5
GRADE BEAM 1 90 0.83 0.5
DEDUCTION 9 π/4 (10")2 6"
TOTAL CFT AFTER DEDUCT
4 11.72 Providing designation 100 A one brick flat soling joints filled with local sqm 283.30 sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 283.3 SQM
GRADE BEAM 1 90 0.83
DEDUCTION 9 π/4 (10")2
COLUMN 9 0.83 0.83
TOTALSFT AFTER DEDUCT
5 4.1.2 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 4420.8 CUM
1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
PILE CAP 9 3 3 0.33
6 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level 4688.3 CUM
1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
PILE CAP 9 2.5 2.5 1.5
7 5.2.2 Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. 5670 CUM
1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
COLUMN 9 0.83 0.83 9
GRADE BEAM 1 90 0.83 0.83
MIDDLE BAND 1 90 0.5 0.83
TOP BAND 1 90 0.5 0.83
8 6.1.12/1 +6.3A Brick work with bricks of class designation 100A in : Cement mortar 1 .:4 (1 cement: 4 coarse sand ). Extra for Brick work in superstructure above plinth level upto floor V cum. 5860.1 CUM
COLUMN 9 0.83 0.83 5
9 13.11.2 Cement plaster in course sand 152.9 SQM
12 mm cement plaster of mix:
1:4(1 cement :4 coarse sand)
COLUMN 8 3 3.33
10 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications. 117.3 SQM
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm.
SAME AS S.NO.-9
11 5.9 Centring and shuttering including strutting,propping etc. and removal of form for.
5.9.1 Foundations, footings, bases of columns etc. for mass concrete. 211.6 SQM
PILE CAP 9 4 3 1.5
GRADE BEAM 2 1 90 0.83
5.9.5 Lintels, beams, plinth bams, griders, bressumers and contilevers. 404.7 SQM
MIDDLE BAND 2 1 90 0.5
TOP BAND 2 1 90 0.5
5.9.6 Columns,Pillars, Piers, Abutments, Posts and Struts. 494.4 SQM
COLUMN 9 4 0.83 9
12 5.22.7B Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. 92.6 KG
Thermo-Mechanically Treated bars TMTC-500-10mm dia.
ITEM NO:- (6+7)
@ 100kg/CUM.taken vide item no ( 6+7)
13 9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 144.5 KG
Fixed to steel windows by welding
BOUNDARY GRILL 1 76.5 3
TOTAL @ 25KG/SQM 25
14 13.81.3 Applying priming coat: 118.1 SQM
With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
13.82.1 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:
New steel work (two or more coats)
AREA VIDE BOTH SIDE (ITEM NO 13)
1.25X MS GRILL 1.25
15 CARRIAGE OF MATERIAL
A BRICKS- 1192.96 /1000
B COARSE SAND- 2398.39 CUM
C LOCAL SAND - 310.47 CUM
D STONE CHIPS- 2601.98 CUM
Add Difference Cost:-
A BRICKS- 281.2 /1000
B CEMENT- 268.03 MT
I TOTAL 586722.58
II PROVIDING 18% GST IN PLACE OF 12% GST (5.36% OF TOTAL) 31448.33
III Seigniorage fee(10%)
A Local sand 21.69 M³
B Coarse sand 28.08 M³
C Stone chips 80.79 M³
D Brick 528.2 /1000
GRAND TOTAL (I+II+III)
(SAY SIX LAKHS THIRTY ONE THOUSAND FIVE HUNDRED THIRTEEN RUPEES ONLY)
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
Material Statement
Sl. No. Item Of Work Quantity Unit Cement in M.T Local Sand in M3 Coarse Sand in M3 Stone Chips M3 Bricks in Nos
1 Local Sand Filling M3
2 B/F soling M2
5 Brick Work M3
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
SEPTIC TANK-2NOS
THE RATES OF ITEMS ARE BASED ON CURRENT S.O.R. OF BUILDING CONSTRUCTION DEPARTEMENT -2022, GOVT. OF BIHAR .
S.NO. CODE NO. DESCRIPTION QUANTITY RATE UNIT AMOUNT
1 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming ofbottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All Kinds of soil. 14.87 360.7 CUM
2 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 0.6 287.3 CUM
3 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 6.98 283.3 SQM
12.5'X6'=75SQF(6.98SQM)
4 4.1.2 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) 4420.8 CUM
QTY SAME ITEM NO :- 2
5 6.1.12/1 Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1 .:4 (1 cement: 4 coarse sand ). Extra for Brick work in superstructure above plinth level upto floor V cum. 5.2 5017.9 CUM
6 5.9.3 Suspended floors, roofs, landings, balcnies and access platform 4.92 437.5 SQM
7 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work upto plinth level.1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20 rr,m nominal size) 4688.3 CUM
QTY SAME ITEM NO :- 2
8 5.22.7B Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. 120 92.6 KG
Mild steel 10.0 mm dia
QTY SAME ITEM NO :- (4+7)(0.6+0.6=1.2CUM)
100KG/CUM=100X1.2=120KG
9 13.17.2 12 mm cement plaster 1:4( 1 cement:4coarse sand) finished with a floating coat of near cement Details of cost for 10 sqm 34.66 192.2 SQM
2X12'6"X7=175SFT(16.26SQM)
2X6X7=84SFT(7.81SQM)
6X7=42SFT(3.90SQM)
2X6X6=72SFT(6.69SQM)
10 CARRIAGE OF MATERIAL
A BRICKS- 1192.96 /1000
B COARSE SAND 2398.39 CUM
C LOCAL SAND 310.47 CUM
D STONE CHIPS- 2601.98 CUM
Add Difference Cost:-
A BRICKS- 281.2 /1000
B CEMENT- 268.03 MT
II PROVIDING 18% GST IN PLACE OF 12% GST (5.36% OF TOTAL)
III SEIGNIORAGE FEE @ 10%
A BRICKS- 528.2 /1000
B COARSE SAND- 28.08 CUM
C LOCAL SAND - 21.69 CUM
D STONE CHIPS- 80.79 CUM
TOTAL(I+II+III)
REQUIRED 2NOS SEPTIC TANK
(SAY ONE LAKH FIFTY FIVE THOUSAND TWO HUNDRED SIXTY SIX RUPEES ONLY)
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
Material Statement
Sl. No. Item Of Work Quantity Unit Cement in M.T Local Sand in M3 Coarse Sand in M3 Stone Chips M3 Bricks in Nos
1 Local Sand Filling 0.6 M3
2 B/F soling 6.98 M2
5 Brick Work M3
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
THE RATES OF ITEMS ARE BASED ON CURRENT S.O.R. OF BUILDING CONSTRUCTION DEPARTEMENT -2022, GOVT. OF BIHAR .
RAIN-WATER HARVESTING
S.No CODE NO. Description Quantity Rate Unit Amount
1 24.1.1.3 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.400 mm dia 16.5 681.5 m
2 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All Kinds of soil. 3.14x(1.00m)2x1.50m 4.714 360.7 CUM
3 6.1.12/A Brick work with bricks of class designation 100A in foundations and plinth in :Cement mortar 1 .:4 (1 cement: 4 coarse sand ).3.14X(1)2}x1.50-3.14x{(0.95)2}X1.5 0.46 5017.9 CUM
4 24.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.3.14x(0.40M)2x1.5 1.886 1343.2 CUM
5 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.3.14x(1.0)2x0.40 1.26 1188.9 CUM
6 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 3.14x(1.50)2x0.40 1.26 1195.6 CUM
7 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -in- charge. 3.14x(1.0)2x0.40 1.26 1195.6 CUM
8 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level. 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate20 mm nominal size). 3.14x(1)2mx0.15 0.471 4688.3 CUM
9 5.22.7A Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars TMTC-500-8mm dia. 0.47/cum@ 90 kg/cum 42.3 94.5 KG
10 5.9.1 Centring and shuttering including strutting,propping etc. and removal of form for.Foundations, footings, bases of columns etc. for mass concrete. (3.14x1x1=3.14) + (3.14x2x0.15=0.94) 4.082 211.6 CUM
11 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All Kinds of soil. 2x2x1.50 6 360.7 CUM
12 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 2x2x0.20 0.8 287.3 CUM
13 4.1.3 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) 2x2x0.1 0.4 3998.1 CUM
14 6.1.12/1 Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1 .:4 (1 cement: 4 coarse sand ) 2x2x.25x1.35= 1.350 cum 2x1x0.25x1.35=0.675 cum 2.025 5017.9 CUM
15 13.17.2 12 mm cement plaster 1:4( 1 cement: 4coarse sand) finished with a floating coat of near cement Details of cost for 10 sqm. 4x1.50x1.35 8.1 192.2 SQM
16 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level. 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size). 2X2X0.15 0.6 4688.3 CUM
17 5.22.7A Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars TMTC-500-8mm dia. 0.60cum@90 kg/cum 54 94.5 kg
18 5.9.1 Centring and shuttering including strutting,propping etc. and removal of form for.Foundations, footings, bases of columns etc. for mass concrete. 1.50x1.50=2.25 sqm + 4x2x0.15=1.20 3.45 211.6 sqm
19 24.3.2 Providing and laying PVC pipe 150mm dia 10m 10 660.1 meter
PROVIDING 18% GST IN PLACE OF 12% GST (5.36% OF TOTAL-A)
NET TOTAL COST OF 1 CHAMBER-
2 CHAMBER SHOULD BE PROVIDED 2
(Say One Lakh Twenty Seven Thousand One Hundred Seventeen Rupees Only)
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
THE RATES OF ITEMS ARE BASED ON CURRENT S.O.R. OF BUILDING CONSTRUCTION DEPARTEMENT -2022, GOVT. OF BIHAR .
WATER SUPPLY & SANITRY FITTINGS WORKS
S.N CODE NO. Description of Items Qty. Rate. Unit Amount
1 18.1 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
18.10.1 15 mm dia nominal bore 30 227.7 m
18.10.2 20 mm dia nominal bore 70 289.5 m
18.10.3 25 mm dia nominal bore 55 399.9 m
2 18.11 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
18.11.1 15 mm dia nominal bore 22 318.9 Each
18.11.2 20 mm dia nominal bore 18 374 Each
3 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore 4 532.3 Each
4 18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
18.46.2 20 mm nominal bore 2 185.6 Each
18.46.3 25 mm nominal bore 2 265.9 Each
5 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2000 9.7 Ltr
6 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 14 434.2 Each
7 18.64 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms 4 106.1 Each
8 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. 6 96.8 Each
9 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 6 1068.5 Each
10 12.78.2 Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter 8 257.5 Each
11 12.79 Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
12 12.8 Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete
13 19.3 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
19.30.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 6 5107.4 Each
14 17.6 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
17.60.2.1 Sand cast iron S&S as per IS - 3989 6 1196 Each
15 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
24.1.1.1 All types of soil 300MM DIA 80 486.8 M
16 24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
17 24.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
18 24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
24.14.2 150 mm clamp 1 1531.4 Each
19 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -incharge.
24.3.2 150 mm nominal size dia 60 660.1 Each
20 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.
18.9.9 100 mm nominal inner dia Pipes 95 2678.4 Each
18.9.8 80 mm nominal inner dia Pipes 125 1889.5 Each
18.9.4 32 mm nominal outer dia Pipes 125 359.1 Each
18.9.3 25 mm nominal outer dia Pipes 178 294.7 Each
18.9.2 20 mm nominal outer dia Pipes 230 205.3 Each
21 17.1.1 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings andfloors wherever required : 1 4470.9 EACH
22 17.81 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including ntegrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 3 14663.5 EACH
W.C. pan with ISI marked white solid plastic seat and lid
23 17.7A Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 8 3932.1 EACH
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
24 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 6 146.3 EACH
25 17.34.2 Providing and fixing toilet paper holder : 6 332.9 EACH
26 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 6 146.3 EACH
27 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. 6 204.7 EACH
28 17.70.1 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 6 325.1 EACH
Bottle t rap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
29 17.69.1 Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. 8 103 EACH
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
30 17.24 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 3 2444.1 EACH
PROVIDING 18% GST IN PLACE OF 12% GST (5.36% OF TOTAL-A)
SAY TEN LAKH NINETEEN THOUSAND AND EIGHTY RUPEES ONLY
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
THE RATES OF ITEMS ARE BASED ON CURRENT S.O.R. OF BUILDING CONSTRUCTION DEPARTEMENT -2023, GOVT. OF BIHAR .
ELECTRICAL WORKS
S.N CODE NO. Description of Items Qty. Rate. Unit Amount
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
1.3.2 Group B 260 947 Points
2 1.4 Wiring for twin control light point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required. 195 1248 pt
3 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 109 309 pt
4 1.6 Wiring for light/ power plug plug with 4 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 105 523 pt
5 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 832 201 m
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 586 246 m
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 388 309 m
1.7.5 2 X 10 sq. mm + 1 X 10 sq. mm earth wire 239 557 m
1.7.6 2 X 16 sq. mm + 1 X 16 sq. mm earth wire 146 775 m
6 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 65 64 Each
7 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 60 531 Each
8 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 88 80 Each
9 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.2 32 Amp, double pole 3 1946 Each
2.1.6 100 Amp, TP&N 1 11043 Each
10 2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way ( 4 + 12 ), double door, horizontal type 4 4184 Each
11 2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
2.5.1 63 Amps 1 3881 Each
2.5.2 100 Amps 1 5019 Each
12 2.6 Providing and fixing following capacity double pole/four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required.
2.6.5 100 Amp, four pole 1 13460 Each
13 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.1 2 + 4 way, single door 1 1447 Each
14 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6/32 amps, Single pole 5 237 Each
15 2.15 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.15.1 40 Amps 3 429 Each
16 2.16 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Each
2.16.2 63 Amps 3 1035 Each
17 3.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal/ coke and salt ) as required. 1 5033 Each
18 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 3 6323 Each
19 3.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. 40 37 M
20 3.9 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 40 133 M
21 5.14.2 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 45 watt 18 3382 Each
22 6.1 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
6.1.8 18 watt 65 1509 Each
23 5.1 Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required. 30 watt 25 2528 Each
24 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
1.23.1 5/6 amps switch 125 37 Each
1.23.4 3 pin , 5/6 amps socket outlet 80 55 Each
1.23.5 6 pin, 15/16 amps socket outlet 65 119 Each
25 8.17.1 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep 6 2572 Each
26 1.41 Installation, testing and commissioning of pre-wired, flourescent fitting / compact flourescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated. Copper conductor , single core cable and earthing etc. as required. 30 134 Each
27 1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm ) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. 40 135 Each
28 7.2.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 40 232 Each
29 7.1.2 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 110 326 Each
30 7.1.3 Above 95 sq. mm and upto 185 sq. mm 40 336 Each
31 2.4 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.14 200 Amp, 35 KA, TPMCCB 1 13776 Each
2.4.15 250 Amp, 35 KA, TPMCCB 1 14739 Each
2.4.19 630 Amp, 50 KA, TPMCCB 1 29686 Each
32 2.3 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 40/63 amps 415 volts, "C" curve TP MCB complete with connections, testing and commissioning etc. as required. 5 2431 Each
33 2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
34 8.1 Supply and fixing pole mounted junction box/fuse box for three phasel 4 core high wattage HPSV/LED/MH street Iight pole with all accessories and connection etc. as required. 22 967 Sq.Ft.
35 2212 3.5 core, 185 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electric cable with aluminium conductor 25 1239 m
36 8.19 Supply and installation of 400 mm, 230 v A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required. 14 3670 Each
37 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. 6 2482 Each
SAY NINETEEN LAKHS TWENTY TWO THOUSAND EIGHT HUNDRED SEVENTY RUPEES ONLY
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
(LS)AS PER MARKET RATE
NON SCHEDULE ITEMS
S.NO. CODE NO. DESCRIPTION QUANTITY RATE UNIT AMOUNT
1 (LS) AS PER MARKET RATE Providing and fixing Auditorium Hall Chair 9000 EACH
Air Conditioner
2 (LS) AS PER MARKET RATE Suppling & Installation of Air Conditioner for Auditorium Centralized Air Conditioner 100000 TONNE
SCREENING & SOUND SYSTEM
3 (LS) AS PER MARKET RATE Suppling & Installation of Sonud System for Auditorium having Specification 8X Electrovoice ELX 200 15P,2X Subwoofer,3x Amplifiers, Mixer (24-channel digital), 4x Wireless Microphone Sets, 4x Monitor Speakers, Stands, racks, accessories, Mixtures, Amps 1 1550000 EACH
4 (LS) AS PER MARKET RATE Suppling & Installation of Screen System with T.V for Auditorium having Specification Screen Size: 100 inches (diagonal) Display Technology: QD-Mini LED Resolution: 4K UHD (3840x2160 pixels) Refresh Rate: 144Hz, Aspect Ratio: 16:9 Viewing Angle: 178 degrees 2 500000 EACH
5 (LS) AS PER MARKET RATE Suppling & Installation of C.C.T.V Camera for Auditorium having Specification -4MP IP DOME (UNCDA41PL3C-L-Y) ILLUMAX-14Pcs, 4MP IP BULLET (UNCTA41PL3C-L-Y) ILLUMAX-10 Pcs, 8CH POE 8+2 GIGA-5 Pcs, SWITCH 8PORT GIGA-1 Pcs, DIGISOL CAT 6 CABLE-1 Pcs, 32CH NVR 4K 2SATA-1 Pcs, 2U MODULAR RACK BOX-5 Pcs, RJ45 CONECTOR-100 Pcs, SAPRETOR BOX-24 Pcs, HARDISK 4TB SEAGATE-2 Pcs, 4U PDU RACK BOX-1 Pcs 1 145000 SET
6 (LS) AS PER MARKET RATE Suppling & Installation of Diesel Generator Set for Auditorium having Specification Prime Duty, 100 Kva, 80 kWe, 3 Phase, Output Voltage-415 V, Frequency 50 Hz, Power Factor-0.8 (lagging), Current (A)-115A, 1500rpm 1 915000 EACH
sumersible pump with starter, pannel
7 (LS) AS PER MARKET RATE Providing and fixing 2 H.P sumersible pump with starter, pannel, cable clamp wall cover etc do all complete job. All complete job as per approved design/drawing, technical specifications and relavent causes of building specification and direction of Engineer-in-charge 1 24700 NOS
ELECTRICAL PANEL WITH INSTALLATION CHARGES
8 (LS) AS PER MARKET RATE Suppling & Installation of ELECTRICAL PANEL WITH INSTALLATION CHARGES 1 120000 Each
(SAY SIXTY NINE LAKH NINETY SIX THOUSAND SEVEN HUNDRED RUPEES ONLY)
BILL OF QUANTITY
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
S.NO. CODE NO.. DESCRIPTION QUANTITY RATE UNIT AMOUNT
1 2.33 Cleaning grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 357.2 100SQM
2 A Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). 902.6 METRE
20.2.1 300 mm dia piles
B 63 CM (25) UNDER -REAM Making 63 cm (25) dia under ream at required with hand auger of approved quality in ordinary soil (vide classification of soil ifem - A) true to plumb and without eccentri city in my stage of opration and disposal of the excavated earth up to 50 mts lead in eluding all lifts , all complete as per approved design and direction of (E/l) 190.2 EACH
3 A Making 25 cm (10") dia bore up to 4 mtr depth below ground with hand auger of approved quality in ordinary soi! (vide classification of soil item A ) true to plumb and without eccentri city in any stage of operation and disposal of the excavated earth up to 50 mtr , Lead in eluding all lifts , all complete as per approved disign and direction of E/l Details of cost for 4 piles of 4 m= 16 mtrs depth ) 178.3 METRE
20.3A.1 25 cm dia piles
B 63 CM (25) UNDER -REAM Making 63 cm (25) dia under ream at required with hand auger of approved quality in ordinary soil (vide classification of soil ifem - A) true to plumb and without eccentri city in my stage of opration and disposal of the excavated earth up to 50 mts lead in eluding all lifts , all complete as per approved design and direction of (E/l) 190.2 EACH
4 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 360.7 CUM
PILE CAP 25 6.5 6.5 2.5
5 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 287.3 CUM
PILE CAP 25 6.5 6.5 0.5
DEDUCTION 100 π (6")2 6"
PILLING 100 0.25 0.5
TOTAL CFT AFTER DEDUCT
6 11.72 Providing designation 100 A one brick flat soling joints filled with local sqm 283.30 sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 283.3 SQM
PILE CAP 25 6.5 6.5
DEDUCTION 100 π (6")2
PILLING 100 0.25
TOTAL SFT AFTER DEDUCT
7 4.1.2 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 4420.8 CUM
1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
DEDUCTION 100 π (6")2 3"
PILLING 100 0.25 0.25
TOTAL CFT AFTER DEDUCT
8 4.1.3 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) 3998.1 CUM
9 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level 4688.3 CUM
1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
PILE CAP 25 6 6 1.66
10 5.2.2 Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. 5670 CUM
1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
TOTAL DEDUCTION
11 6.1.12C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1.:4 (1 cement: 4 coarse sand ) 5116.3 CUM
TOTAL DEDUCTION
12 6.1.12C +6.3C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1.:4 (1 cement: 4 coarse sand ) Extra tor Brick work in superstructure above plinth level upto floor V cum 5958.5 CUM
ELECTRIC PANEL ROOM 1 25.91 0.83 13
HALL SITTING STEP
SITTING STEP 1 42.5 4 0.5
ENTRANCE 1 9 1 0.5
BACK TOILET 2 13 0.41 10
FRONT TOILET 1 15.91 0.41 13
SITTING STEP 2 28 0.41 2.5
MEZZANINE 1 42.5 0.41 2.5
CONTROL ROOM 1 20 0.83 15.5
DEDUCTION (DOORS, WINDOW, VENTILATOR & COLUMN)
STAIR DOOR 2 4.5 0.83 7
PASSAGE DOOR 1 5 0.83 8
WINDOW 2 4 0.83 4
VENTILATION 4 2 0.83 1
13 6.1.12/1 Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1 .:4 (1 cement: 4 coarse sand ). Extra for Brick work in superstructure above plinth level upto floor V cum. 5017.9 CUM
14 6.1.12/1 +6.3A Brick work with bricks of class designation 100A in : Cement mortar 1 .:4 (1 cement: 4 coarse sand ). Extra for Brick work in superstructure above plinth level upto floor V cum. 5860.1 CUM
COLUMN 9 0.83 0.83 5
15 5.33A.2.2 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc. 5677.2 CUM
WINDOW 3 5 0.5 0.83
LINTEL BAND 4 66 0.83 0.83
ROOF BEAM B1 1 65 0.83 0.91
ROOF BEAM B 3 18.91 0.83 1
CONTROL ROOM 1 10 10 0.5 17.41 9.41
BACK ROOM & TOILET 2 17.41 9.41 0.41 4.5 1
LANDING 4 4.5 4.5 0.375
16 5.9 Centring and shuttering including strutting,propping etc. and removal of form for.
5.9.1 Foundations, footings, bases of columns etc. for mass concrete. 211.6 SQM
PILE CAP 25 4 6 1.66
5.9.5 Lintels, beams, plinth bams, griders, bressumers and contilevers. 404.7 SQM
LINTEL 5 2 4.5 0.5
WINDOW 3 2 5 0.5
LINTEL BAND 4 2 66 0.83
5.9.6 Columns,Pillars, Piers, Abutments, Posts and Struts. 494.4 SQM
5.9.3 Suspended floors, roofs, landings, balcnies and access platform. 437.5 SQM
ROOF SLAB 8 31.66 4
BALCONY 1 33.33 4.5
CONTROL ROOM 1 10 10
BACK ROOM & TOILET 1 17.41 9.41
STAIR 24 4.5 0.5
LANDING 4 4.5 4.5
17 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
5.22.7A Thermo-Mechanically Treated bars TMTC-500-8mm dia. 94.5 KG
5.22.7B Thermo-Mechanically Treated bars TMTC-500-10mm dia. 92.6 KG
5.22.7C Thermo-Mechanically Treated bars TMTC-500-12mm dia. 11500 90.8 KG
5.22.7D Thermo-Mechanically Treated bars TMTC-500-16mm dia. 5500 91.7 KG
5.22.7E Thermo-Mechanically Treated bars TMTC-500-20mm dia. 1000 91.7 KG
5.22.7F Thermo-Mechanically Treated bars TMTC-500-25mm dia. 1400 91.7 KG
18 10.17 Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete. 174.6 EACH
19 10.5.2 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer 3467.9 SQM
20 13.24.2 6 mm cement plaster to ceiling of mix : 1:4(1 cement: 4 coarse sand) 125.6 SQM
BACK ROOM 2 11.58 9
BACK TOILET 1 9 4
FRONT TOILET 2 15.91 4.75
ELECTRIC PANEL ROOM 1 15.91 10
PORTICO 1 32.5 18.083
BALCONY 1 33.33 4.5
TOILET 2 6 4.75
CONTROL ROOM 1 10 10
21 13.11.2 Cement plaster in course sand 152.9 SQM
12 mm cement plaster of mix:
1:4(1 cement :4 coarse sand)
BACK TOILET 2 13 10
BACK ROOM 2 20.58 10
FRONT TOILET 2 20.66 13
ELECTRIC PANEL ROOM 2 25.91 13
CONTROL ROOM 2 20 10
MEZZANINE 2 28.91 15.5
STAIR DOOR 2 2 4.5 7
PASSAGE DOOR 1 2 5 8
VENTILATION 4 2 2 1
TOTAL AREA AFTER DEDUCT
22 13.17.2 12 mm cement plaster 1:4( 1 cement:4coarse sand) finished with a floating coat of near cement Details of cost for 10 sqm 192.2 SQM
23 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 105.4 SQM
SUM OF SL NO 16+ SL NO 17
24 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exterior using Primer as per manufacturers specifications. 117.3 SQM
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm.
SAME STY SL NO. 19
25 11.34 38 mm thick parquet (wood block) flooring of 1st class teak wood laid over 25 mm thick levelling layer of cement concrete 1:2:4(1 cement:2 coarse sand:4 store aggregate 10 mm nominal size) to be paid separately coated with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen (blown type) upto half depth,planed,levelled smooth and finished complete. 7936.3 SQM
STAGE FLOOR 1 24.66 22.41
26 11.41.2 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete. 1638.8 SQM
Size of Tile 60x60 cm
BACK TOILET 2 9 4
BACK ROOM 2 12.58 10
SITTING STEP 6 43.5 4
FRONT TOILET 2 15.91 4.75
ELECTRIC PANEL ROOM 1 16.91 11
BELOW THE STAIR 1 19.083 11
PORTICO 1 21.33 18.58
ENTRANCE STEP 6 9 1
STAGE STEP 18 4 0.83
CONTROL ROOM 1 11 11
MEZZANINE 8 32.66 4
LANDING 4 5 4.5
27 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 795 SQM
DEDUCT DOOR 4 2.5 7
28 2.25(A) Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead. 411.7 CUM
BACK TOILET 2 9 4 6
BACK ROOM 2 11.58 9 6
FRONT TOILET 2 15.91 4.75 3
ELECTRIC PANEL ROOM 1 15.91 10 3
BELOW THE STAIR 1 18.083 10 3
29 10.36 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). 546.8 KG
Stair Case ( Railing) 1 13 3.5
MEZZANINE Railing 1 42.5 1
SITTING STEP 2 28 1
30 10.5.2 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer 3467.9 SQM
MAIN GATE 1 9 8
31 9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 144.5 KG
Fixed to steel windows by welding
MUMTY ROOM 2 4 6
32 13.81.3 Applying priming coat: 118.1 SQM
With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
13.82.1 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:
New steel work (two or more coats)
AREA VIDE BOTH SIDE (ITEM NO 25+26)
33 10.16.2 Steel work in built up tubular trusses including cutting, hoisting,, fixing in position and applying a priming coar of approved steel primer, welded and bolted including special shaped washers etc. complete: 137.9 KG
Hot finished seamless type tubes
Structural Steel Truss + Columns + Purlins + Bracing 1200
Main Trusses Fabricated Steel 600
Purlins C 200 x 75 x 20 x 2.5 mm 500
Bracing & Sag Rod 20 mm / 16 mm dia 256
Base Plates & Misc. Connection Plates, Cleats 400
G.i Gutters, Down Pipes, Anchor Bolts, HSFG Bolts, Self Drilling Screws 800
34 13.17.2 +13.36.2 12 mm cement plaster 1:4( 1 cement: 4coarse sand) finished with a floating coat of near cement Details of cost for 10 sqm 199.4 SQM
Extra for providing and mixing water proofing material in proportion recommended by the manufacturers:
12 mm cement plaster 1:4(1 cement :4 sand)
ROOF SLAB 8 31.66 4
BALCONY 1 33.33 4.5
CONTROL ROOM 1 10 10
35 12.1.1 Providing corrugated G.S. sheet roofing fixed with G.I.J. or hooks, bolts and nuts 8 mm diameter with bitumen and G. I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (upto a pitch of 60°) excluding the cost or purlins, rafters and trusses. 1792.3 SQM
1.00 mm thick with zinc coating not less than 275 gm/mz
36 9.147 A2 Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multichambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance 9076.1 SQM
Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm).
STAIR DOOR 1 4.5 7
PASSAGE DOOR 1 5 8
37 26.23.1 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of mainT runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 1812.4 SQM
With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
MEZZANINE 1 31.36 28.75
38 26.24.1 Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete. 2359.6 SQM
15 mm thick fully With perforated square/butt edge light weight calcium silicate panels/ tiles
MEZZANINE 2 27.91 12
39 26A.7 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: 4474.2 SQM
FRONT FACE 1 119.5 13
MAIN GATE 1 9 8
40 24.1.1.3 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.400 mm dia 33 681.5 m
41 24.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 3.772 1343.2 CUM
42 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge 2.52 1188.9 CUM
43 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 2.52 1195.6 CUM
44 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -in- charge. 2.52 1195.6 CUM
45 24.3.2 Providing and laying PVC pipe 150mm dia 10m 20 660.1 meter
46 18.1 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
18.10.1 15 mm dia nominal bore 30 227.7 m
18.10.2 20 mm dia nominal bore 70 289.5 m
18.10.3 25 mm dia nominal bore 55 399.9 m
47 18.11 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
18.11.1 15 mm dia nominal bore 22 318.9 Each
18.11.2 20 mm dia nominal bore 18 374 Each
48 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore 4 532.3 Each
49 18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
18.46.2 20 mm nominal bore 2 185.6 Each
18.46.3 25 mm nominal bore 2 265.9 Each
50 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2000 9.7 Ltr
51 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 14 434.2 Each
52 18.64 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms 4 106.1 Each
53 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. 6 96.8 Each
54 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 6 1068.5 Each
55 12.78.2 Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter 8 257.5 Each
56 12.79 Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
57 12.8 Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete
58 19.3 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
19.30.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 6 5107.4 Each
59 17.6 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
17.60.2.1 Sand cast iron S&S as per IS - 3989 6 1196 Each
60 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
24.1.1.1 All types of soil 300MM DIA 80 486.8 M
61 24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
62 24.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
63 24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
24.14.2 150 mm clamp 1 1531.4 Each
64 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -incharge.
24.3.2 150 mm nominal size dia 60 660.1 Each
65 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.
18.9.9 100 mm nominal inner dia Pipes 95 2678.4 Each
18.9.8 80 mm nominal inner dia Pipes 125 1889.5 Each
18.9.4 32 mm nominal outer dia Pipes 125 359.1 Each
18.9.3 25 mm nominal outer dia Pipes 178 294.7 Each
18.9.2 20 mm nominal outer dia Pipes 230 205.3 Each
66 17.1.1 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings andfloors wherever required : 1 4470.9 EACH
67 17.81 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including ntegrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. 3 14663.5 EACH
W.C. pan with ISI marked white solid plastic seat and lid
68 17.7A Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 8 3932.1 EACH
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
69 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 6 146.3 EACH
70 17.34.2 Providing and fixing toilet paper holder : 6 332.9 EACH
71 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 6 146.3 EACH
72 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. 6 204.7 EACH
73 17.70.1 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 6 325.1 EACH
Bottle t rap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
74 17.69.1 Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. 8 103 EACH
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
75 17.24 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 3 2444.1 EACH
76 CARRIAGE OF MATERIAL:-
A BRICKS- 1192.96 /1000
B COARSE SAND- 2398.39 CUM
C LOCAL SAND - 310.47 CUM
D STONE CHIPS- 2601.98 CUM
Add Different Cost-
A BRICKS- 281.2 /1000
B CEMENT 268.03 MT
77 Seigniorage Fee:-
(A).Local sand- 21.69 M³
(B).Coarse sand- 28.08 M³
(C).Stone chips- 80.79 M³
ELECTRICAL WORKS
78 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
1.3.2 Group B 260 947 Points
79 1.4 Wiring for twin control light point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required. 195 1248 pt
80 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 109 309 pt
81 1.6 Wiring for light/ power plug plug with 4 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 105 523 pt
82 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 832 201 m
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 586 246 m
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 388 309 m
1.7.5 2 X 10 sq. mm + 1 X 10 sq. mm earth wire 239 557 m
1.7.6 2 X 16 sq. mm + 1 X 16 sq. mm earth wire 146 775 m
83 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 65 64 Each
84 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 60 531 Each
85 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 88 80 Each
86 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.2 32 Amp, double pole 3 1946 Each
2.1.6 100 Amp, TP&N 1 11043 Each
87 2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way ( 4 + 12 ), double door, horizontal type 4 4184 Each
88 2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
2.5.1 63 Amps 1 3881 Each
2.5.2 100 Amps 1 5019 Each
89 2.6 Providing and fixing following capacity double pole/four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required.
2.6.5 100 Amp, four pole 1 13460 Each
90 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.1 2 + 4 way, single door 1 1447 Each
91 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6/32 amps, Single pole 5 237 Each
92 2.15 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.15.1 40 Amps 3 429 Each
93 2.16 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.16.2 63 Amps 3 1035 Each
94 3.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal/ coke and salt ) as required. 1 5033 Each
95 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 3 6323 Each
96 3.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. 40 37 M
97 3.9 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 40 133 M
98 5.14.2 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 45 watt 18 3382 Each
99 6.1 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
6.1.8 18 watt 65 1509 Each
100 5.1 Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required. 30 watt 25 2528 Each
101 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
1.23.1 5/6 amps switch 125 37 Each
1.23.4 3 pin , 5/6 amps socket outlet 80 55 Each
1.23.5 6 pin, 15/16 amps socket outlet 65 119 Each
102 8.17.1 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep 6 2572 Each
103 1.41 Installation, testing and commissioning of pre-wired, flourescent fitting / compact flourescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated. Copper conductor , single core cable and earthing etc. as required. 30 134 Each
104 1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm ) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. 40 135 Each
105 7.2.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 40 232 Each
106 7.1.2 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 110 326 Each
107 7.1.3 Above 95 sq. mm and upto 185 sq. mm 40 336 Each
108 2.4 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.14 200 Amp, 35 KA, TPMCCB 1 13776 Each
2.4.15 250 Amp, 35 KA, TPMCCB 1 14739 Each
2.4.19 630 Amp, 50 KA, TPMCCB 1 29686 Each
109 2.3 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 40/63 amps 415 volts, "C" curve TP MCB complete with connections, testing and commissioning etc. as required. 5 2431 Each
110 2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
111 8.1 Supply and fixing pole mounted junction box/fuse box for three phasel 4 core high wattage HPSV/LED/MH street Iight pole with all accessories and connection etc. as required. 22 967 Sq.Ft.
112 2212 3.5 core, 185 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electric cable with aluminium conductor 25 1239 m
113 8.19 Supply and installation of 400 mm, 230 v A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required. 14 3670 Each
114 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. 6 2482 Each
NON SCHEDULE ITEMS
115 (LS) Providing and fixing Auditorium Hall Chair 9000 EACH
Air Conditioner
116 (LS) Suppling & Installation of Air Conditioner for Auditorium Centralized Air Conditioner 100000 TONNE
SCREENING & SOUND SYSTEM
117 (LS) Suppling & Installation of Sonud System for Auditorium having Specification 8X Electrovoice ELX 200 15P,2X Subwoofer,3x Amplifiers, Mixer (24-channel digital), 4x Wireless Microphone Sets, 4x Monitor Speakers, Stands, racks, accessories, Mixtures, Amps 1 1550000 EACH
118 (LS) Suppling & Installation of Screen System with T.V for Auditorium having Specification Screen Size: 100 inches (diagonal) Display Technology: QD-Mini LED Resolution: 4K UHD (3840x2160 pixels) Refresh Rate: 144Hz, Aspect Ratio: 16:9 Viewing Angle: 178 degrees 2 500000 EACH
119 (LS) Suppling & Installation of C.C.T.V Camera for Auditorium having Specification -4MP IP DOME (UNCDA41PL3C-L-Y) ILLUMAX-14Pcs, 4MP IP BULLET (UNCTA41PL3C-L-Y) ILLUMAX-10 Pcs, 8CH POE 8+2 GIGA-5 Pcs, SWITCH 8PORT GIGA-1 Pcs, DIGISOL CAT 6 CABLE-1 Pcs, 32CH NVR 4K 2SATA-1 Pcs, 2U MODULAR RACK BOX-5 Pcs, RJ45 CONECTOR-100 Pcs, SAPRETOR BOX-24 Pcs, HARDISK 4TB SEAGATE-2 Pcs, 4U PDU RACK BOX-1 Pcs 1 145000 SET
120 (LS) Suppling & Installation of Diesel Generator Set for Auditorium having Specification Prime Duty, 100 Kva, 80 kWe, 3 Phase, Output Voltage-415 V, Frequency 50 Hz, Power Factor-0.8 (lagging), Current (A)-115A, 1500rpm 1 915000 EACH
sumersible pump with starter, pannel
121 (LS) Providing and fixing 2 H.P sumersible pump with starter, pannel, cable clamp wall cover etc do all complete job. All complete job as per approved design/drawing, technical specifications and relavent causes of building specification and direction of Engineer-in-charge 1 24700 NOS
ELECTRICAL PANEL WITH INSTALLATION CHARGES
122 (LS) Suppling & Installation of ELECTRICAL PANEL WITH INSTALLATION CHARGES 1 120000 Each
123 PROVIDING 18% GST IN PLACE OF 12% GST- 860271
124 TOTAL AMOUNT-
(SAY TWO CRORE FIFTY NINE LAKH FORTY ONE THOUSAND EIGHT HUNDRED FIFTY TWO RUPEES ONLY)
Sl.no. SR Ref. Item NO L B H Quantity Unit Rate Amount
1 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m.
Septic tank 1 3 2 2 cum
Soakpit 1 1.7 2 cum
2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Septic tank 1 cum
Soakpit 3.14 0.25 cum
Total cum 287.3
11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Septic tank 1 sqm
Soakpit 3.14 0.25 sqm
Total sqm 283.3
4.1.2 Providing and laying in position cement concrete 1:1.5:3 of specified gradeexluding the cost of centring and shuttering-all work upto plinth level
Septic tank 1 0.15
Soakpit 3.14 0.25 0.15
5.1.2 Providing and laying in position specified grade of reinforce cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work putoplinth level 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate20 mm nominal size)
Septic tank 1 0.15
6.1.12A Brick work with bricks of class designation 100A in foundations and plinth inCement mortar 1 .:4 (1 cement: 4 coarse sand )
Septic tank 2 0.25 1.8
Net B/W cum 5017.9
6.1.14A Brick work with bricks of class designation 100A in foundations and plinth inCement mortar 1 .:6 (1 cement: 6 coarse sand )
Soakpit 3.14 0.25 2
Net B/W cum 4819.9
5.22.7B Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
2.5 kg per cft Kg 92.6
13.17.1 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement
Septic tank 2 sqm
Soakpit 3.14 sqm
Net C.P sqm 203.6
Difference of Cost of Materials
Carriage of Materials
Coarse Sand Cum
Stone Chips Cum
Difference cost of Royalty
Coarse Sand Cum
Stone Chips Cum
Add 5.36% GST Factor on A+B+C
Seigniorage Fee
Coarse Sand Cum
Stone Chips Cum
Calculation for material consumption
Item Qty Unit Cement Chips Sand Brick L.Sand
bags cum cum nos cum
Local sand filling cum
Brick Flat Soling sqm
12 mm plaster sqm
CONSTRUCTION OF 150MM X 100MM DIA & 125M DEEP TUBE WELL
S.No. Item Code Description Qty. Rate Amount
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 150 metre depth below ground level. (All types of soil)
1 24.1.1.1 (b) 300mm dia bore from G.L m to 90.0M M 90 486.8
2 24.2.1 (d) 300mm dia bore from 90.0M to 150.0M M 35 567.9
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC (UPVC) medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
3 24.3.2 (a) 150 mm nominal size dia M 30 660.1
4 24.3.1 (b) 100 mm nominal size dia M 65 546.1
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC (UPVC) medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
5 24.4.1 100 mm nominal size dia M 30 573.1
Supplying the following fittings & fixing the same in position as per approved lowering assembly and strata chart including providing all equipments and welding the same on process of lowering the assay etc. all complete as per S/D of E/I.
6 24.13.2 (a) 150 mm dia well cap No. 1 210.7
7 24.14.2 (b) 150 mm dia M.S. Clamp 1.6 M long (one Pair) No. 1 1531.4
8 AR 1 (c) 150 mm dia center guide Nos. 4 150
9 AR 2 (d) 100 mm dia center guide Nos. 6 100
10 AR 3 (e) 150 mm x 100 mm dia 6mm wall thickness MS reducer No. 1 500
11 24.15.1 (f) 100mm dia & 6mm thick M.S. well shoe plug No. 1 228.3
12 24.8 Gravel packing in tubewell construction in accordance with IS:4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. M3 5.36 1343.2
13 AR 4 Carriage of Pea-Gravel to be used in Gravel Packing M3
14 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water sampl &getting tested in approved laboratory, disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hrs. 24 916.8
15 AR 5 Supplying all materials and labours for arrangement for additional water required during the drilling period for 70 Hrs & site clearance & leveling etc. And providing the soap duster etc. to staff engaged in drilling etc. all complete work as per specification & direction of E.I. No. 1 7000
Add extra for GST- 5.36%
Name of work Estimate for Provision of Electrical Wiring & Electrical Installation
SL.No Code Details of Items Qty Rate (as per BCD Electrical SOR 2023) Unit Amount
1 1.3.3 Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable size G.I box etc. as required. Group - 'C' 50 1146 Point
Light Point -30
Fan/Wall Fan Point/Exhaust Fan - 20
1.59 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc as required.
2 1.59.3 Group C 20 609 Point
3 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 40 309 Metre
1.7 Wiring for circuit/ submain wiring along with earth wire with the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
4 1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (For circuit & street light) 110 201 Metre
5 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For 5A D.S ) 100 246 Metre
6 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Computer Terminal) 120 246 Metre
7 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(For AC) 80 309 Metre
8 1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire(For LDB & CDB) 100 660 Metre
9 1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire(For PDB) 80 925 Metre
10 1.31 Supplying and fixing suitable size G.I box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc, as required. 25 414 Each
11 1.32 Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc, as required. 12 531 Each
12 1.33 Supplying and fixing 2 pin, 5 amp. ceiling rose on the existing junction box/PVC box including connection etc as required. 18 64 Each
13 1.34 Supplying and fixing batten/angle holder including connection etc. as required. 18 80 Each
1.27 Supplying and fixing following modules G.I. box along with modular base and cover plate for modular switches in recess etc as required.
14 1.27.1 1 or 2 module (75mm X 75mm) 18 234 Each
15 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 12 683 Each
16 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 30 521 Each
Detailed Estimate For Fire Hydrant System
S.No CODE No. DESCRIPTION OF WORK/ ITEM NO/ Qty UNIT RATE AMOUNT
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with twoor more coats of synthetic enamel paint of requiredshade complete as required
27.8.6 80 mm dia 5 meter 1082
27.8.7 100 mm dia 32 meter 1445
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required
27.9.2 Single headed Stainless steel 4 Each 5722
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets andconforming to IS 780 of following sizes as required :
27.13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 4 Each 1236
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required
Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
27.15.2 100 mm dia 2 Each 6048
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required
27.16.2 Stainless steel (Grade 304) 4 Set 4445
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following asrequired. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
27.18.2 Stainless steel (Grade 304) 4 Each 1631
Supplying and fixing of fire brigade connection of cast iron body withgun metal male instantaneous inlet couplings complete with cap andchain as reqd. for suitable dia MS pipe connection conforming to IS904 as required :
27.19.1 2 way-100 mm dia M.S. Pipe 2 Set 6331
27.2 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MSsheet, 1200 mm in height with air release valve on top and flangedconnection to riser, drain arrangement with 25 mm dia gun metalwheel valve with required accessories, pressure gauge andpaintingwith synthetic enamel paint of approved shade as required. 1 Set 17707
27.22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 1 Each 1442
TOTAL AFTER ADDING 5.36% GST
Total Cost For Fire Hydrant System
समस्तीपुर जिलान्तर्गत विद्यापति नगर प्रखंड में मॉडल सिलाई वर्कशेड का निर्माण कार्य
THE RATES OF ITEMS ARE BASED ON CURRENT S.O.R. OF BUILDING CONSTRUCTION DEPARTEMENT -2022, GOVT. OF BIHAR . INCL. OF ADDITIONAL 5.36% GST AND EXTRA COST FOR ROYALTY
S.NO. ITEM NO. DESCRIPTION QUANTITY RATE UNIT AMOUNT
NOS LENGTH WIDTH HEIGHT TOTAL
1 2.33 Cleaning grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 357.2 100SQM
2 20.2.1 Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). 902.6 METRE
300 mm dia piles
3 20.3A.2 63 CM (25) UNDER -REAM Making 63 cm (25) dia under ream at required with hand auger of approved quality in ordinary soil (vide classification of soil ifem - A) true to plumb and without eccentri city in my stage of opration and disposal of the excavated earth up to 50 mts lead in eluding all lifts , all complete as per approved design and direction of (E/l) 190.2 EACH
4 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 360.7 CUM
PILE CAP 3.5 3.5 2.5
5 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 287.3 CUM
Stair 1 5 15 0.5
Landing Platform 1 5 10.83 0.5
Loading Unloading Deck 1 14 16 0.5
Guard Room 1 8 6 0.5
DEDUCTION π (6")2 6"
PILLING 0.25 0.5
TOTAL CFT AFTER DEDUCT
6 11.72 Providing designation 100 A one brick flat soling joints filled with local sqm 283.30 sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 283.3 SQM
Landing Platform
Loading Unloading Deck
DEDUCTION π/4 (6")2
TOTAL SFT AFTER DEDUCT
7 4.1.2 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 4420.8 CUM
1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Guard room floor 1 8 5 0.33
Guard room Plinth beam 1 26 0.83 0.33
DEDUCTION π/4 (6")2 3"
PILLING 0.25 0.33
TOTAL CFT AFTER DEDUCT
8 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level 4688.3 CUM
1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
GRADE BEAM 0.83
Guard room G beam 0.83
9 5.2.2 Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. 5670 CUM
1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
10 6.1.12C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1.:4 (1 cement: 4 coarse sand ) 5116.3 CUM
TOTAL DEDUCTION
11 6.1.12C +6.3C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1.:4 (1 cement: 4 coarse sand ) Extra tor Brick work in superstructure above plinth level upto floor V cum 5958.5 CUM
Guard room 1 26 0.83 9
Loading Unloading Deck 1
Front and Back Triangle Section 1 42 0.83 6
DEDUCTION (DOORS, WINDOW, VENTILATOR & COLUMN)
12 5.33A.2.2 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc. 5677.2 CUM
Lintel Beam 10' 2 290 0.83 0.83
Lintel Beam 5' 1 0.33
Roof Slab Mezzanine 1 32 22.5 0.42
Roof Slab Guard Room 2 8 6 0.42
Lintel Beam Gurard Room 2 26 0.83 0.5
Top Beam G. room 2 26 1 1
Window Slab 28 4 3 0.25
5.9 BCD SOR Centring and shuttering including strutting,propping etc. and removal of form for.
13 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. 211.6 SQM
5.9.5 Lintels, beams, plinth bams, griders, bressumers and contilevers. 404.7 SQM
Window sides 0.25
14 5.9.6 Columns,Pillars, Piers, Abutments, Posts and Struts. 494.4 SQM
15 5.9.3 Suspended floors, roofs, landings, balcnies and access platform. 437.5 SQM
Gurad Room Slab 2
TOTAL SQM total RCC Work in Cum cum
5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete RF @ 150kg/cum Kg
16 5.22.7A Thermo-Mechanically Treated bars TMTC-500-8mm dia. 94.5 KG 0.22
17 5.22.7B Thermo-Mechanically Treated bars TMTC-500-10mm dia. 92.6 KG 0.3
18 5.22.7C Thermo-Mechanically Treated bars TMTC-500-12mm dia. 90.8 KG 0.2
19 5.22.7D Thermo-Mechanically Treated bars TMTC-500-16mm dia. 91.7 KG 0.18
20 5.22.7E Thermo-Mechanically Treated bars TMTC-500-20mm dia. 91.7 KG 0.1
Total Reinforcement KG
21 10.17 Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete. 174.6 EACH
22 10.5.2 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer 3467.9 SQM
Total Area inclusive of doors, RS and CG is
23 13.24.2 6 mm cement plaster to ceiling of mix : 1:4(1 cement: 4 coarse sand) 125.6 SQM
Mezzanine floor bottom 1 32 22.5
Guard Room 1 8 6
24 13.11.2 Cement plaster in course sand 152.9 SQM
12 mm cement plaster of mix:
1:4(1 cement :4 coarse sand)
Total Running Feet 1 538 9
TOTAL AREA AFTER DEDUCT
25 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 105.4 SQM
SUM OF SL NO 16+ SL NO 17
26 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exterior using Primer as per manufacturers specifications. 117.3 SQM
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm.
SAME STY SL NO. 19
27 11.41.2 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete. 1638.8 SQM
Size of Tile 60x60 cm
Mezzanine Floor 32 22.5
Ground Floor 10 15
Operational Area 75 36
28 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 795 SQM
29 10.32.1 Steel work in welded builtup section do all complete job for stairs 104 Kg
30 10.36 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). 546.8 KG
Outer Railing 1 51 3.5
MEZZANINE Railing 1 32 5
Steel Stair Railing 4 12 3.5
31 9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 144.5 KG
Fixed to steel windows by welding
Window 28 4 4.5
32 13.81.3+13.82.1 Applying priming coat: 118.1 SQM
With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:
New steel work (two or more coats)
AREA VIDE BOTH SIDE (ITEM NO 25+26)
33 10.16.2 Steel work in built up tubular trusses including cutting, hoisting,, fixing in position and applying a priming coar of approved steel primer, welded and bolted including special shaped washers etc. complete: 137.9 KG
Hot finished seamless type tubes
Item Nos Length Unit Wt
End Ridge 2 16.62
Truss (Standard Commercial Grade) 11 600
34 12.1.1 Providing corrugated G.S. sheet roofing fixed with G.I.J. or hooks, bolts and nuts 8 mm diameter with bitumen and G. I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (upto a pitch of 60°) excluding the cost or purlins, rafters and trusses. 1792.3 SQM
1.00 mm thick with zinc coating not less than 275 gm/mz
35 12.51.6 Providing Gutter 600 mm overall girth for water 898.7 M
36 26.23.1 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of mainT runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 1812.4 SQM
With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
37 26A.7 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: 4474.2 SQM
FRONT FACE 0.5 34 6
38 16.78.2 Providing GSB with material conforming to Grade II as per the directions of EIC do all complete job CUM
39 10.79.1 Providing Paver Block 80 mm thick M35 Grade Concrete SQM
40 6.1.12A Brick work with bricks of class designation 100A in foundations and plinth inCement mortar 1 .:4 (1 cement: 4 coarse sand ) CUM
41 6.1.14A Brick work with bricks of class designation 100A in foundations and plinth inCement mortar 1 .:6 (1 cement: 6 coarse sand ) CUM
42 13.17.1 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement SQM
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 150 metre depth below ground level. (All types of soil)
43 24.1.1.1 (b) 300mm dia bore from G.L m to 90.0M M
44 24.2.1 (d) 300mm dia bore from 90.0M to 150.0M M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC (UPVC) medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
45 24.3.2 (a) 150 mm nominal size dia M
46 24.3.1 (b) 100 mm nominal size dia M
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC (UPVC) medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
47 24.4.1 100 mm nominal size dia M
Supplying the following fittings & fixing the same in position as per approved lowering assembly and strata chart including providing all equipments and welding the same on process of lowering the assay etc. all complete as per S/D of E/I.
48 24.13.2 (a) 150 mm dia well cap No.
49 24.14.2 (b) 150 mm dia M.S. Clamp 1.6 M long (one Pair) No.
50 AR 1 (c) 150 mm dia center guide Nos.
51 AR 2 (d) 100 mm dia center guide Nos.
52 AR 3 (e) 150 mm x 100 mm dia 6mm wall thickness MS reducer No.
53 24.15.1 (f) 100mm dia & 6mm thick M.S. well shoe plug No.
54 24.8 Gravel packing in tubewell construction in accordance with IS:4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. M3
55 AR 4 Carriage of Pea-Gravel to be used in Gravel Packing M3
56 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water sampl &getting tested in approved laboratory, disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hrs.
57 AR 5 Supplying all materials and labours for arrangement for additional water required during the drilling period for 70 Hrs & site clearance & leveling etc. And providing the soap duster etc. to staff engaged in drilling etc. all complete work as per specification & direction of E.I. No.
58 10.32.2 Steel work welded in built up sections/framed worK including cutting
hoisting, rixing in position and applying a priming coat of approved steel
primer using structural steel, etc. as required
In gratings, frames, guard bar, ladders, railings, brackts. gates & Kg
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with twoor more coats of synthetic enamel paint of requiredshade complete as required
59 27.8.6 80 mm dia meter
60 27.8.7 100 mm dia meter
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required
61 27.9.2 Single headed Stainless steel Each
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
62 27.11.5 100 mm dia Set
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets andconforming to IS 780 of following sizes as required :
63 27.12.5 100 mm dia Set
64 27.13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. Each
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required
65 27.14.5 100 mm dia Set
Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
66 27.15.2 100 mm dia Each
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required
67 27.16.2 Stainless steel (Grade 304) Set
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following asrequired. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
69 27.18.2 Stainless steel (Grade 304) Each
Supplying and fixing of fire brigade connection of cast iron body withgun metal male instantaneous inlet couplings complete with cap andchain as reqd. for suitable dia MS pipe connection conforming to IS904 as required :
70 27.19.1 2 way-100 mm dia M.S. Pipe Set
71 27.2 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MSsheet, 1200 mm in height with air release valve on top and flangedconnection to riser, drain arrangement with 25 mm dia gun metalwheel valve with required accessories, pressure gauge andpaintingwith synthetic enamel paint of approved shade as required. Set
72 27.22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Each
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,
73 18.7.1 15mm nominal outer dia pipe Metre
74 18.7.2 20mm nominal outer dia pipe Metre
75 18.7.3 25mm nominal outer dia pipe Metre
76 18.7.4 32mm nominal outer dia pipe Metre
77 18.7.5 40mm nominal outer dia pipe Metre
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.
78 18.8.1 15mm nominal outer dia Pipes Metre
79 18.8.2 20mm nominal outer dia Pipes Metre
Providing and fixing brass stop cock of approved quality (screwed end).
80 18.16.1 15mm nominal bore Each
81 18.16.2 20mm nominal bore Each
Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end).
82 18.17.1 25mm nominal bore Each
83 18.17.2 32mm nominal bore Each
84 18.17.3 40mm nominal bore Each
Providing and fixing gun metal non-return valve of approved quality (screwed end)
32mm nominal bore
85 18.19.2.1 Horizontal Each
Providing and fixing uplasticised PVC connectionpipe with brass ions
86 18.21.2.1 15 mm nominal bore Each
87 Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931 Each
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS stamdards and weighing notless than 810 gms.
88 18.50.1 15 mm nominal bore Each
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.
89 18.51.1 15 mm nominal bore Each
Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
90 18.52.1 15mm nominal bore Each
Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved quality conforming to IS: 8931
91 18.53.1 15mm nominal bore Each
Cutting holes up to 30 x 30 cm in walls including making good the same:
92 18.76.1 With common burnt clay F.P.S. (non modular) bricks Each
93 18.77 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof. Each
94 18.79 Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba. Each
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
95 17.7.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Each
96 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings Each
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
97 17.28.2.2 40 mm dia Each
98 Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete. Each
99 Providing and fixing 600 x 120 x 5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc. complete Each
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
100 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm an effective height of 88 mm, weighthan 190 gms Each
12.78 Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
101 12.78.2 110mm diameter Metre
12.79 Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Single pushfit Coupler:
Single tee with door
Single tee without door
105 12.79.5.2 110mm bend Each
106 12.79.6.2 110mm Shoe Each
12.80 Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete.
108 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. Each
17.1 Providing and fixing water closet squatting pan (Indian type W.C pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
109 17.1.1 White Vitreous china Orissa Pattern W.C pan of size 580x440mm with integral type foot rests. Each
17.2 Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
110 17.2.1 W.C pan with ISI marked white solid plastic seat and lid. Each
17.10 Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S 13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.
Kitchen sink with drain board
111 17.10.1.1 510x1040 mm bowl depth 250 mm Each
112 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than 105gms. Each
17.5. Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass lush pipe,spreaders with unionsand clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I.trap with outlet grating and other couplings in C.P. brass, includingpainting of fittings and cutting and making good the walls and floors wherever required :
113 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern Each
114 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 90 gms. Each
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
115 19.1.2 150 mm diameter Metre
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes inlcuding bed concrete as per standard design.
116 19.2.2 150mm diameter S.W. pipe Metre
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
117 19.4.3.1 180x150 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each
19.30.1 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design
118 19.30.1.0 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each
CARRIAGE OF MATERIAL:-
120 B COARSE SAND- 2486.15 CUM
121 C LOCAL SAND - 317.14 CUM
122 D STONE CHIPS- 2711.98 CUM
Add Different Cost-
124 B CEMENT 268.03 MT
Extra cost of Royalty 73.59 /1000
125 1 Bricks 133.79 CUM
126 2 Coarse Sand 468.28 CUM
127 3 Stone Chips C 130 50
TOTAL (A+B) 25 5
128 PROVIDING 18% GST IN PLACE OF 12% GST (5.36% OF TOTAL A+B) 8 6
Seigniorage Fee:- Net Area for Roads sqft
129 (A).Local sand- 14.19 M³
130 (B).Coarse sand- 27.58 M³
131 (C).Stone chips- 94.54 M³
TOTAL (I+II+III)
133 1.3.3 Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable size G.I box etc. as required. Group - 'C' Point
Light Point -30
Fan/Wall Fan Point/Exhaust Fan - 20
1.59 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc as required.
134 1.59.3 Group C Point
135 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre
1.7 Wiring for circuit/ submain wiring along with earth wire with the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
136 1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (For circuit & street light) Metre
137 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For 5A D.S ) Metre
138 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Computer Terminal) Metre
139 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(For AC) Metre
140 1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire(For LDB & CDB) Metre
141 1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire(For PDB) Metre
142 1.31 Supplying and fixing suitable size G.I box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc, as required. Each
143 1.32 Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc, as required. Each
144 1.33 Supplying and fixing 2 pin, 5 amp. ceiling rose on the existing junction box/PVC box including connection etc as required. Each
145 1.34 Supplying and fixing batten/angle holder including connection etc. as required. Each
1.27 Supplying and fixing following modules G.I. box along with modular base and cover plate for modular switches in recess etc as required.
146 1.27.1 1 or 2 module (75mm X 75mm) Each
147 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. Each
148 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. Each
149 AR-1 Design/supply/installation of Exterion signage to Be fixed with the Help of Aluminium pipe Framework and Cladded with 3mm ACP(As per site Requirement IfNeeded)and Letters to Be made of stainless steel of 304 Grade Raised by 25mm From the Base The Scope Includes Completion of Job in All Respects Including Hardware in All HINDI/ENGLISH & URDU Language Letter Size 15" SET
ABSTRACT+ESTIMATE PHE WORKS
Sl. No. SOR-22 Code Description of Work building Unit Rate (Rs.) Amount (Rs.)
WATER SUPPLY WORKS Rate as per new alalysis of BCD 2022
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,
1 18.7.1 15mm nominal outer dia pipe 75 Metre 172
2 18.7.2 20mm nominal outer dia pipe 56 Metre 233.9
3 18.7.3 25mm nominal outer dia pipe 75 Metre 317.3
4 18.7.4 32mm nominal outer dia pipe 84 Metre 395.2
5 18.7.5 40mm nominal outer dia pipe 42 Metre 538.4
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.
6 18.8.1 15mm nominal outer dia Pipes 85 Metre 278.2
7 18.8.2 20mm nominal outer dia Pipes 50 Metre 350.8
Providing and fixing brass stop cock of approved quality (screwed end).
8 18.16.1 15mm nominal bore 16 Each 303.8
9 18.16.2 20mm nominal bore 14 Each 328
Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end).
10 18.17.1 25mm nominal bore 14 Each 532.3
11 18.17.2 32mm nominal bore 16 Each 589.9
12 18.17.3 40mm nominal bore 11 Each 707.3
Providing and fixing gun metal non-return valve of approved quality (screwed end)
32mm nominal bore
13 18.19.2.1 Horizontal 20 Each 677.6
Providing and fixing uplasticised PVC connectionpipe with brass ions
14 18.21.2.1 15 mm nominal bore 45 Each 85.2
15 18.49 Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931 10 Each 434.2
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS stamdards and weighing notless than 810 gms.
16 18.50.1 15 mm nominal bore 10 Each 715.1
18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.
17 18.51.1 15 mm nominal bore 8 Each 708.4
18.52 Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
18 18.52.1 15mm nominal bore 12 Each 594.8
18.53 Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved quality conforming to IS: 8931
19 18.53.1 15mm nominal bore 15 Each 500.4
Cutting holes up to 30 x 30 cm in walls including making good the same:
20 18.76.1 With common burnt clay F.P.S. (non modular) bricks 20 Each 198.5
21 18.77 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof. 10 Each 217.1
22 18.79 Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba. 10 Each 115.7
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
23 17.7.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 5 Each 2369.9
24 17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 2 Each 1500
17.28 Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
26 17.31 Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete. 5 Each 1068.5
27 17.33 Providing and fixing 600 x 120 x 5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc. complete 10 Each 713.3
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
28 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm an effective height of 88 mm, weighthan 190 gms 5 Each 424
12.78 Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
29 12.78.2 110mm diameter 100 Metre 257.5
12.79 Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Single pushfit Coupler:
Single tee with door
Single tee without door
12.80 Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete.
36 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. 8 Each 47.9
17.1 Providing and fixing water closet squatting pan (Indian type W.C pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
37 17.1.1 White Vitreous china Orissa Pattern W.C pan of size 580x440mm with integral type foot rests. 3 Each 4470.9
17.2 Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
38 17.2.1 W.C pan with ISI marked white solid plastic seat and lid. 2 Each 4230
17.10 Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S 13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.
Kitchen sink with drain board
39 17.10.1.1 510x1040 mm bowl depth 250 mm 1 Each 5231.5
40 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than 105gms. 10 Each 146.3
17.5. Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass lush pipe,spreaders with unionsand clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I.trap with outlet grating and other couplings in C.P. brass, includingpainting of fittings and cutting and making good the walls and floors wherever required :
41 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern 2 Each 6469
42 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 90 gms. 10 Each 204.7
19.1 Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
43 19.1.2 150 mm diameter 25 Metre 464.3
19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes inlcuding bed concrete as per standard design.
44 19.2.2 150mm diameter S.W. pipe Metre 494.4
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
19.4.3.1 180x150 mm size P type
45 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1 Each 1994.1
19.30.1 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design
46 19.30.1.0 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1 Each 4266.8
Adding 5.36% Extra For GST
S.No. Item Code Description Qty. Rate Amount
Steel Work for Storage Rack
Steel work welded in built up sections/framed worK including cutting
hoisting, rixing in position and applying a priming coat of approved steel
primer using structural steel, etc. as required
1 10.32.2 In gratings, frames, guard bar, ladders, railings, brackts. gates &
2.5 Kg per Sqft for 2100 sqft = `5250 kg
Add extra for GST- 5.36%
S.No. Item Code Description Qty. Rate Amount
1 AR-1 Design/supply/installation of Exterion signage to Be fixed with the Help of Aluminium pipe Framework and Cladded with 3mm ACP(As per site Requirement IfNeeded)and Letters to Be made of stainless steel of 304 Grade Raised by 25mm From the Base The Scope Includes Completion of Job in All Respects Including Hardware in All HINDI/ENGLISH & URDU Language Letter Size 15"
Content Name :-
मॉडल सिलाई वर्कशेड, समस्तीपुर
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
SAMSATIPUR Re NIT-04.pdf
NIT • 2.51 MB
SAMSATIPUR Re NIT-04 PAPER CUTTING.pdf
NIT • 0.70 MB
BOQ GR-01 SAMSATIPUR Re NIT-04.pdf
NIT • 6.00 MB
BOQ GR-01 SAMSATIPUR Re NIT-04.xls
NIT • 0.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .