Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹31.9 L Quoted ₹32.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹33.9 L+₹1.1 L (3.35%)Rejected-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | ₹33.9 L+₹1.1 L (3.35%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹36.4 L+₹3.5 L (10.8%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹36.4 L+₹3.5 L (10.8%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹36.5 L+₹3.6 L (11.1%)Rejected-AOC 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | ₹36.5 L+₹3.6 L (11.1%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹50.7 L+₹17.9 L (54.4%)Rejected-AOC | ₹50.7 L+₹17.9 L (54.4%) | L5 | Rejected-AOC Rejected |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Mar 2024, 6:00 pmClosed
GARRISON ENGINEER
GE (U) Chandimandir PIN-134107
GE(U)/CHM-45/2023-24 REPAIR MAINTENANCE OF DEFUNT AIR TERMINATION NETWORK, AVIATION LIGHTS EARTHING AND SECURITY LIGHTS WITH CONNECTED ELECTRICAL ACCESSORIES AT VARIOUS WATER SUPPLY INSTALLATIONS UNDER GE (U) CHANDIMANDIR
2024_MES_644280_1
GE(U)/CHM-45/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Chandimandir
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (U) Chandimandir
₹96,000
Yes
5 Sept 2024
27 Feb 2024
30 Mar 2024
27 Feb 2024
27 Mar 2024
13 Mar 2024
Amount
Excavation in trenches for foundations, laying / taking out of cables, erecting of poles etc, any type of soil, not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr in width and getting out, complete all as specified and as directed.
Returning, filling in soils, in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removing excavated soils to a distance exceeding 50 metres and not exceeding 100 metres and depositing where directed at a level not exceeding 1.50 metreabove the starting point.
Bricks burnt clay subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified and as directed.
M & L for sand cushioning for protection of cable (below, above and around the cable laid in trenches) all as specified and as directed. Note: Punned thickness shall be measured.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections all as specified and directed by Engineer – in - Charge.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 4 core nominal cross section in service connections all as specified and directed by Engineer – in - Charge.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 2 core nominal cross section in service connections all as specified and directed by Engineer – in - Charge.
Supply and laying as in replacement 40 mm bore tube "light grade" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge.
Supply and laying as in replacement 50 mm bore tube "light grade" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge.
Supply and laying as in replacement 80 mm bore tube "light grade" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge.
Supply and fixing , in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing ,i n replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing , in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
M&L for brackets made out of 40mm bore light grade tube galvanised including bending to shape or welding, drilling etc as required complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in replacment of Hot pressed moulded SMC junction box of size not less than 240mm x 130 mmx 95 mm, side hinged door with lockable arrangement bus bar TPN capacity 200 Amps with one No MCB 2.50 Amp SP 10 KA ‘C’ curve with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole or grouting in PCC muff complete all as specified and as directed, with and including taking out unserviceable junction box and removing from site of work complete all as directed.
Supply and laying in PVC insulated FRLS copper conductor multi stranded cable 2 run of size 2.5 sqmm fixing from fitting to junction box including taking out complete all as specified and as directed.
M & L cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in lintels up to 1.5 m clear span, seismic and other similar bands, benching, coping, bed blocks, apex stones and kerbs etc including use of necessary form work all as specified and directed by Engineer - in - Charge .
Supply and fixing in replacement, LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing in replacement, LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing in replacement, LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing in replacement, LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing in replacement, LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing ,in replacement of post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp complete.
Supply and fixing ,in replacement of post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp complete.
S&F in replacement, industrial type 150 watt Highbay energy saving light, environment friendly & robust Highbay LED luminaire with high efficacy suitable for ceiling Surface/Suspended) IP 65 including provn of three core cable of copper conductor suitable for fitting upto 1.5 RM not less than 1.5 sqmm dia each core , from ceiling rose to fitting terminal for making connection, fixing the fitting on wall/ceiling including all necessary fixing accessories complete all as directed
S&F in replacement, for 20 watt Surface or wall mounted LED batten light fitting , extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% complete with connecting suitable cable from ceiling rose to fitting all as directed by Engr-in-charge as complete all as directed
S&F in replacement, steel tubular electric pole, swaged type, welded, type 410 SP-31 (9 metre long) complete with CI base plate, pole cap, bolts, nuts & screws all as specified and directed
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point , fan point complete incl fittings such as switches, sockets, ceiling rose, holder socket, light fittings, regulators and making good disturbed surfaces of wall , floor , ceiling etc and removing materials all as directed and as specified.
M & L point wiring complete with 1.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and sheathed cable drawn through in existing conduit with and including sunk type MS pressed steel terminal box for mounting fittings like switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light/ bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer - in- charge.
All as per Srl item No. 30 here in before but for socket out let 3 pin 5 amp on same board all as specified and directed by Engineer - in - Charge
All as per Srl item No. 30 here in before but for socket out let 3 pin 5 amp on independent board all as specified and directed by Engineer - in - Charge
All as per Srl item No. 30 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and unsheathed cable for one multipurpose switch socket outlet 6 pin, 15 Amps on independent board including 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
S & F switch piano flush button single pole one way 5 Amp all as specified and directed by Engineer - in – Charge.
S & F switch piano flush button single pole one way 15 Amp all as specified and directed by Engineer - in – Charge.
S & F socket outlet 2 in 1, 3 pin, 5 Amps, flush type all as specified and directed by Engineer-in –Charge.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed by Engineer-in-Charge.
S & F ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .
S&F as in repairs PVC gang box with provision of 5 Amp Switch Socket combination to be fitted on wall along with screw,nuts all as specified and directed by Engineer-in-Charge
S&F as in repairs PVC gang box with provision of 15 Amp Switch Socket combination to be fitted on wall along with screw,nuts all as specified and directed by Engineer-in-Charge
S & F as in repairs MCB distribution board of sheet metal single pole and neutral 4 way, single door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F as in repairs MCB distribution board of sheet metal single pole and neutral 8 way, single door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F as in repairs MCB double pole 40 to 63 Amp 240 volt with rupturing capacity not less than 10 KA all as specified and directed by Engineer – in – Charge .
S & F as in repairs MCB single pole 6 to 32 Amp 240 volt with rupturing capacity not less than 10 KA all as specified and directed by Engineer – in – Charge .
S & F as in repairs MCB single pole 40 Amp 240 volt with rupturing capacity not less than 10 KA all as specified and directed by Engineer – in – Charge .
S & F as in repairs MCB, Single pole & neutral, 240 Volt, 40 Amps, C-Series braking capacity 10 KA all as specified and directed by Engineer - in - Charge.
Supply and fixing in replacement, TPN DB , 4 Way (4+12 modules) double door , IP43 degree protection, Complete all as specified and as directed.
S & F in replacement, Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amp, 415 Volt & outgoing 4 way having IP 43 protection complete.
Supply and fixing in replacement, MCB TPN , 'B' series. 10 KA, 240 Volts, 63 Amps capacity, complete all as specified and as directed.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 6 Sqmm multi stranded copper conductor drawn through existing conduit/ casing and capping with and including PVC FRLS insulated 6 Sqmm multi stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge Notes : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4 Sqmm multi stranded copper conductor drawn through existing conduit/ casing and capping with and including PVC FRLS insulated 4 Sqmm multi stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge Notes : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated copper conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 3 core nominal cross section in service connections all as specified and directed by Engineer – in - Charge.
S&F in replacement of MCCB 63 A ,3 pole ,16 KA (Ics =100% Icu) with fixed thermal & magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 100 A ,3 pole ,16 KA (Ics =100% Icu) with fixed thermal & magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 125 A ,3 pole ,16 KA (Ics =100% Icu) with fixed thermal & magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 160 A ,3 pole ,36 KA (Ics =100% Icu) with fixed thermal & magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 200 A ,4 pole ,36 KA (Ics =100% Icu) with fixed thermal & magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 250 A ,4 pole ,36 KA (Ics =100% Icu) with fixed thermal & magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 400 A ,4 pole ,36 KA (Ics =100% Icu) with fixed thermal & magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of MCCB 630 A ,4 pole ,36 KA (Ics =100% Icu) with fixed thermal & magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps with all protection by pass facility, shunt & UVT with breaker ON/ OFF, Trip indication complete all as specified and directed.
Painting of 9 m steel pole with cross arms, clamp of any length and shape for LT overhead line with two coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 15 cm dia yellow circle & marking bands width 30 cm by fluorescent paint as directed by Engr-in Charge, from bottom of pole to 1.5 Mtr height, complete all as specified and directed.
Material and labour in Replacement for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth strip 25X4mm as earth lead by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 10 Cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
Supply and fixing in replacement of Phase indicator lamp, LED Type of colour red, blue and yellow (set of three), in replacement (taking down old lamp) complete all as specified and as directed
Supply and fixing in replacement of Indicator lamp,LED type of colour red/green, in replacement (taking down old lamp) complete all as specified and as directed
Supply and fixing of Lock for Panel rotary type with all accessories, as per existing (size and shape), in replacement (taking down old lock), complete all as specified andas directed .
Taking down defective exhaust fan of size 380mm and strippping out of burnt winding and cleaning rotor slots and making surface smooth and including re-winding of exhaust fan 380mm sweep with super enamelled copper winding wire of appropriate guage as per existing guage with insulation material of exhaust fan any make and model with and including of greasing/ oiling, testing and including cleaning entire body with cloth and painting two coats with super enamelled paint existing colour and refix on exixting location complete all as specified and as directed.
Supply and fixing in replacement single pole and neutral enclosures with two pin and earth plug and socket complete with one single pole MCB 240 V 20 Amps all as specified and directed by Engineer - in - Charge.
M & L in replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long all as specified and directed by Engineer - in - Charge .
M & L in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed by Engineer - in - Charge .
S&F as in repairs Galvanised iron strip 32 x 6mm buried in ground all as specified and directed by Engineer - in - Charge .
S&F as in repairs Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed by Engineer - in - Charge .
Fixing only as in repairs Galvanised iron strip 32 x 6mm buried in ground all as specified and directed by Engineer - in - Charge .
Supply and fixing in replacement of LED Aviation light fitting, Aluminium cast, low intensity with and including aviation obstruction lamp of 230 volt total power consumption 14W, 50 Hz, max forward current-150mA, viewing all direction, protection weather proof IP-65 complete all as specified and directed .
S & F as in repairs two single core cables PVC FRLS insulated unsheathed 2.5 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 2.5 Sqmm stranded copper conductor cable as earth continuity conductor for fixing on OHT and all connecting / fitting accessories complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
Design, fabricate, supply, installation, testing and commissioning in replacement of outdoor type dust proof & vermin proof cubical panel board compartmentalized with seperate bus and cable alley chambers suitable for 3 phase, 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory (Manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with powder coating painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame and four legs of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:2:4, type B1 using 20mm graded stone aggregate.
Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. The size of panel board shall not be less than 850mm x 550mm x 400mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and directed:-
Note: (i) Factory made name plates with feeder names / Bldg Nos shall be fixed on relevant incomer / outgoing MCCB doors. (ii) The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
Design, fabricate, supply, installation, testing and commissioning in replacement of outdoor type dust proof & vermin proof cubical panel board compartmentalized with seperate bus and cable alley chambers suitable for 3 phase, 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory (Manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with powder coating painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame and four legs of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:2:4, type B1 using 20mm graded stone aggregate.
Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. The size of panel board shall not be less than 850mm x 550mm x 400mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and directed:-
Note: (i) Factory made name plates with feeder names / Bldg Nos shall be fixed on relevant incomer / outgoing MCCB doors. (ii) The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
Supply and fixing in replacement Digital Soft Starter of current rating 110 A suitable for Motor 3 phase, 50 Hz, 415 V, with heat sink, internal by pass, supply voltage limits from 200V to 480 V, phase failure and thermal protection, complete all as specified and directed.
Supply and fixing in replacement Digital Soft Starter of current rating 140 A suitable for Motor 3 phase, 50 Hz, 415 V, with heat sink, internal by pass, supply voltage limits from 200V to 480 V, phase failure and thermal protection, complete all as specified and directed.
Supply and fixing in replacement Digital Soft Starter of current rating 170 A suitable for Motor 3 phase, 50 Hz, 415 V, with heat sink, internal by pass, supply voltage limits from 200V to 480 V, phase failure and thermal protection, complete all as specified and directed.
Supply and fixing in replacement Digital Soft Starter of current rating 480 A suitable for Motor 3 phase, 50 Hz, 415 V, with heat sink, internal by pass, supply voltage limits from 200V to 480 V, phase failure and thermal protection, complete all as specified and directed.
M&L Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for foundations, mass and for repairing to paths/ road & hardstanding etc. including necessary cutting of roads/ paths for passing of pipes and making good the disturbed portion complete all as specified and directed by Engineer – in - Charge.
Material and labour in replacement of old and deteriorated MS Sheet of any size and shape from the outdoor/indoor panel 3.00 thick and fix on outdoor/indoor panel as per required size and shape complete inclusive fixing the hinges, door lock etc, inclusive super enamelled paint as per existing colour over two coat of red oxide primer complete all as specified and specified.
S & F in replacement rolled mild steel channel, angle or tee sections, fixed independently, without connection plate, etc Fe-290 (Gde E-165) including nuts, bolts and washers for base frame of motor pump set and the like, drilling of holes of suitable size for bolts & painting with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge .
S & F in replacement change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole, in steel metal enclosure, capacity 125 Amps rated current manually operated conforming to IS : 13947 or latest edition with high thermal and dynamic strength to withstand short circuit current level of 80 KA rms, in replacement, (taking down old damaged change over switch) complete all as specified and as directed.
S & F in replacement change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole, in steel metal enclosure, capacity 160 Amps rated current manually operated conforming to IS : 13947 or latest edition with high thermal and dynamic strength to withstand short circuit current level of 80 KA rms, in replacement, (taking down old damaged change over switch) complete all as specified and as directed.
S & F in replacement change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole, in steel metal enclosure, capacity 400 Amps rated current manually operated conforming to IS : 13947 or latest edition with high thermal and dynamic strength to withstand short circuit current level of 80 KA rms, in replacement, (taking down old damaged change over switch) complete all as specified and as directed.
S & F in replacement change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole, in steel metal enclosure, capacity 200 Amps rated current manually operated conforming to IS : 13947 or latest edition with high thermal and dynamic strength to withstand short circuit current level of 80 KA rms, in replacement, (taking down old damaged change over switch) complete all as specified and as directed.
Supply and fixing in replacement HRC Fuse 250/200/150 Amps complete all as specified and as directed.
Supply and fixing in replacement CT of 300/5 including complete wiring complete all as specified and as directed.
Supply and fixing in replacement CT of 200/5 including complete wiring complete all as specified and as directed.
M & L in replacement Thermal Over Load Relay Range, Conforms to IS/IEC 60947-4-1, Protection against overload & phase loss protection,complete all as specified and directed
M & L in replacement MG21DF Analog Voltage Protection Relay, measurement of Protection Relay, Under Voltage, Over Voltage, Phase Asymmetry, Phase Failure, Phase Sequence complete all specified as directed
Supply and fixing in replacement Heavy Duty Cylindrical Capacitors 7.5 KVAR complete all as specified and as directed.
Supply and fixing in replacement Heavy Duty Cylindrical Capacitors 10 KVAR complete all as specified and as directed.
Supply and fixing in replacement Heavy Duty Cylindrical Capacitors 15 KVAR complete all as specified and as directed.
Supply and fixing in replacement Heavy Duty Cylindrical Capacitors 20 KVAR complete all as specified and as directed.
Supply and fixing in replacement duty contactor 10 KVAR ,3P inbuilt 1 NO/NC auxiliary contact complete all as specified and directed.
Supply and fixing in replacement duty contactor 12 KVAR,3P inbuilt 1 NO/NC auxiliary contact complete all as specified and directed.
Supply and fixing in replacement duty contactor 15 KVAR, 3P inbuilt 1 NO/NC auxiliary contact complete all as specified and as directed.
M&L for oiling, greasing of ceiling fan/ exhaust fan/ wall fan checking for fault and overhauling and replacement of condensor complete all as directed
Taking down defective ceiling fan of size 1200mm of after disconnecting electric connection for re-winding, overhauling and strippping out of burnt winding and cleaning rotor slots and making surface smooth for re-winding with super enamelled copper winding wire of appropriate guage as per existing guage with insulation material of ceiling fan any make and model with and including of greasing/ oiling, testing and including cleaning entire body with cloth and painting two coats with super enamel paint existing colour including testing, re-fixing on existing location complete all as specified and as directed.
Supply and fix in replacement 3 pole power contactor MNX-75 complete all as specified and directed.
Supply and fix in replacement 3 pole power contactor MNX-15 complete all as specified and directed.
S&F as in repairs of fan blade for ceiling fan Aluminium of size 1200 mm sweep of any make and model aero dyanamically balanced including screwed for fixing and taking down existing complete all as specified and as directed.
S & F DOL starter for induction motor capacity of 1 HP to 3 HP Three phase, 415 V, 50 Hz as per specified and directed by Engr-in-charge.
Supply and fixing Galvanised Iron perforated cable tray of size 200mm and thickness 2mm for laying of cables complete all as specified and directed.
Supply and fix in replacement 3 pole power contactor 415 volt 50 Hz, 185 Amp complete all as specified and directed.
Supply and fix in replacement 3 pole power contactor 415 volt 50 Hz, 95 Amp complete all as specified and directed.
Supply and fix in replacement 3 pole power contactor 240 volt 50 Hz, 15 Amp complete all as specified and directed.
M/s Friends Engineering Works
R D Bansal
Alpha Engineers and Builders
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .