Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹17.5 LAccepted-AOC | l1 | Accepted-AOC BEING LOWEST | |
| 2 | l2₹24.3 L+₹5.1 L (26.9%)Rejected-Finance | l2 | Rejected-Finance Being Not lowest | |
| 3 | l3₹25.0 L+₹5.9 L (30.7%)Rejected-Finance | l3 | Rejected-Finance Being Not lowest | |
| 4 | l4₹27.5 L+₹8.3 L (43.5%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | l4 | Rejected-Finance Being Not lowest | |
| 5 | l5₹28.7 L+₹9.6 L (50.0%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | l5 | Rejected-Finance Being Not lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ARJUN PATRO,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
REPAIR AND MAINTENANCE OF HT/LT DAMAGED CABLE AND ELECTRICAL BREAKDOWN INCLUDING FAULT DETECTING, LOCALIZATION, RECTIFICATION WORK IN HT/LT UNDER GROUND CABLES, OH LINES AT KARAM VIHAR MAP, 285 FD WKSP, 261 AB, TIGRIS ROAD MAP, SU
2022_MES_555511_1
GE ELECT/D-65/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹70,000
Yes
5 Jan 2023
13 Oct 2022
10 Dec 2022
13 Oct 2022
8 Dec 2022
28 Oct 2022
Amount
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 1 here in before but 1100 Volt LT cables
Taking out faulty underground 11000 Volt HT cable of different sizes by excavation and removing bricks/cable covers of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks/cable covers as required. Note: (a) 11000 Volt HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks/cable covers will be laid in trenches for cable protection. If extra bricks/PCC cable cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 3 here in before but 1100 Volt LT cables
Material and labour disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :-
25-50 Sqmm x 3.5 core/ 4 core
70-185 Sqmm x 3.5 core
240-400 Sqmm x 3.5 core
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.
All as per srl item No 14 here-in-before but using old cable cover obtained under srl item No 10 here in before.
S&F sub class B bricks having minimum compressive strength 75Kg/Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per srl item No 16 here-in-before but using old bricks obtained under srl item No 10 here in before.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed of following sizes. Note :-Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
95 sqmm 3 core.
120 sqmm 3 core.
150 sqmm 3 core.
185 sqmm 3 core
240 sqmm 3 core
300 sqmm 3 core
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed. Cables of the following sizes:- Note :-Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 80 to 100 mm bore and making good both ends all specified and directed
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes
S&F cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar 150mm c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enemel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33 /11KV as directed by Engr-in-charge complete all as specified and directed. Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm including necessary excavation & earthwork for cable route indicator deemed to be included in the item.
M & L for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole, Transformer, LT panels, in and outside area of HT/LT Sub stn and removing all rubbish to a distance not exceeding 50 m as directed.
Disconnecting and taking down existing 3 way 11 KV outdoor type Ring Main Unit carefully from 255 transit camp and transporting to panchwati for installtion complete all as specified and directed by Engineer - in- charge .
M&L Brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete as specified and directed .
M & L for PCC 1:3:6 type C-2 (using 40 mm gradded aggregate) for foundation, filling and mass concrete etc complete all as specified and directed .
M & L for cement concrete type B-2, 1:2:4, 75 mm thick (using 40 mm gradded aggregate) for floors and paving etc complete all as specified and directed.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement complete as specified and directed.
S&F equal Angle iron, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
S&F 4 mm thick mild steel wire 50x25 mm mesh up into mattressess or cages, lapped wired and fixed in position including welded for fencing to grid in cluding one coat of primer and two coat ot synthetic enamel paint complete all as specified and directed.
M & L for 2 coat of synthetic enamel painting over a coat of red oxide to steel surfaces including preparation of newly surface complete all as specified.
NOTE :-(i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
INDIAN CONSTRUCTION CO.
DYNAMIC BUILDING SOLUTIONS
mayur enterprises
Vijay Electricals
MV Engineers And Contractors
Ridhi engineers and builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .