| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.9 LAccepted-AOC NO 2C THANGAVEL VAITHIYAR STREET TRIPLICANE CHENNAI 600 005 | CHENNAI | CHENNAI | TAMIL NADU | 600005 | ₹36.9 L Quoted ₹37.7 L | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA |
| 2 | 2₹44.0 L+₹6.3 L (16.8%)Rejected-Finance 88 30 RAMASAMY GARDEN ADYAR ARUNACHALAPURAM ADYAR CHENNAI TAMIL NADU 600020 | CHENNAI | TAMIL NADU | 600020 | ₹44.0 L+₹6.3 L (16.8%) | 2 | Rejected-Finance NOT BEING LOWEST TENDERER |
| 3 | 3₹45.6 L+₹7.9 L (21.1%)Rejected-Finance NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | ₹45.6 L+₹7.9 L (21.1%) | 3 | Rejected-Finance NOT BEING LOWEST TENDERER |
| 4 | 4₹46.2 L+₹8.5 L (22.7%)Rejected-Finance | ₹46.2 L+₹8.5 L (22.7%) | 4 | Rejected-Finance NOT BEING LOWEST TENDERER |
| 5 | 5₹46.3 L+₹8.6 L (22.9%)Rejected-Finance NO 2 RAJAJI STREET SRI DEVI NAGAR SOUTH KAMARAJ NAGAR CHENNAI 600 071 | CHENNAI | CHENNAI | TAMIL NADU | 600071 | ₹46.3 L+₹8.6 L (22.9%) | 5 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Sept 2024, 6:55 pmClosed
GE Chennai
GE Chennai 600009
REPAIRS TO BRICK WALLS, ROOF AND ROOF TREATMENT, FALSE CEILING, CHAJJAS, PLASTERING ETC AND CONNECTED WORKS AT ZONE A AND C UNDER GE CHENNAI
2024_MES_668483_1
8757
Open Tender
Civil Works
Item Rate
273 days
GE Chennai
As per tender documents
7 documents required · 7 mandatory
₹500
GE Chennai
₹90,000
Yes
9 Dec 2024
31 Aug 2024
5 Oct 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
Amount
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling of wall and ceiling boards ( fibre pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and as directed.
M & L for galvanised powder coated snap grid framework of size 605 x 605mm for false ceiling all as specified including vinyl laminated MPL gypsum panels ( GYPTECH) 9mm thick of size 60 x 60 cm fixing with staples on snap grid by means of GI wires not less than 4mm dia hooks and raw plug etc centre of make that shall match with existing make i.e., GYPTECH/ARMSTRONG or equivalent complete all as specified and as directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for fly ash brick work with sub class B bricks straight or curved on plan exc 6M mean radius built in CM 1:4 complete all as specified and as directed.
Demolition in portion ordered madras terrace roofs in lime mortar ,Reinforced brickwork in suspended slabs, beams, lintels etc. in cement mortar or cement concrete including 15 mm thick rendering the junction of wall and madras terrace roof in CM 1 : 3 including supporting /scaffolding to bottom floor/slab while demolition complete all as specified and as directed. Note : while demolishing any damage caused to existing structure the same will be rectified with out any extra cost
Dismantling timber scantlings 40sq. cm and over in section, in any position un framed work including filling the voids of embedded portion of wood into the wall with PCC 1: 2 : 4 (20 MM graded aggregates ) including finished the surface smooth and even complete all as specified and as directed.
Demolition in portion as ordered of brick or stone masonry , built in lime mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Taking down cement plaster on brick work or stone walls etc including racking out of joint , hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work in two layers, first layer 10mm thick in CM 1:6 and second finishing coat 5mm thick in CM 1:4 mixed with water proofing compound as per manufacturers instructions and finished even and fair on external surfaces complete all as specified and as directed.
15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and as directed.
Gl wire netting 0.90mm dia & 12mm mesh in patches of lathing to wood or metal studding, joists, etc. in walls. Ceilings, stanchions, beams, etc. including all laps, cutting & waste complete all as specified and as directed.
Dubbing out average 15mm thick on irregular face of walls in patches in CM (1:4) complete all as specified and directed.
M&L Rendering in CM 1:3, 10 mm thick as in ceiling in patches not exceeding 5.00 sqm on fair faces of concrete surfaces including finished even and fair without using extra cement in patches complete all as specified and as directed.
M & L for applying three coat of white wash as in ceiling incl preparation of newly plastered ceiling surfaces complete all as specified and as directed.
Preparation of new plasters surfaces of wall and applying plaster of Paris putty of 1 mm thickness over newly plastered surface to prepare the surface even and smooth and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification and as specified and as directed.
Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered /treated surfaces of walls complete all as specified and as directed. Make : APEX of Asian or equivalent of Shalimar / Nerolac/ Berger.
S&F in repairs 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod &high density plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m - 2 1 0 g m s) complete all as specified and as directed.
S&F in repairs 25 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod &high density plastic ball screwed for iron pipe and fixed. (Minimum weight 2 5 m - 455 g m s .) complete all as specified and as directed.
M&L for preparation of the surface thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles in existing old terraces with brick bat coba or screeds, damaged or hollow portions, sharp edges, etc. shall be cut and removed till the mother slab is exposed and washing down with clean water to remove all dirt etc., The slab shall be recoated with slurry of Dr. Fixit Pidicrete URP or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP and cement in 1:1 proportion. After drying, the surface cracks shall be filled with Dr. Fixit. Crack-X or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP or polymer-modified mortar in case cracks are wider than 5 mm.Cracks less than 2 mm, shall be cleaned free of dust with a vacuum cleaner. Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be applied in the crack and shall be allowed to dry. Dr. Fixit new coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be then poured into these cracks and shall be allowed to dry . Bitumen based waterproofing treatments if existing, must be completely removed by mechanical scarification or by any other effective mechanical means. 2 parts of Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be diluted with 1 one part of water. This dilution will cover 7 to 8 sq.mt and shall be allowed to dry for 6 to 8 hrs. First coat of Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be applied without any dilution at the rate of 2 m2 per litre and shall be allowed to dry before taking up the second and third coats, the rate of application being the same and open woven glass fibre mesh of 2.5 mm x 2.5 mm must be sandwiched between the first and second coat. While the 1st coat is still wet, the fibre mesh shall be placed on it. After the coat dries, the 2nd coat of Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be applied.
Item No. 23.01 Contd/- Notes: a) All movements in cracks and cold joints in the substrate caused by variations of high and low temperatures shall be taken care. b) This reinforcement with fibre mesh shall be extended up to the drip mould over the angle fillets. c) The sequence of colours of Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP. can be decided depending on the desired top coat colour. Drying time between coats will be 6 to 8 hrs. d) The system may be allowed to air cure for 7 days minimum. e) A total film thickness of 1 to 1.2 mm must be achieved when measured after drying. d) 7 days after application of Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP, it should be checked for its adhesion to the substrate. For this, a square of 5 cm x 5 cm shall be marked for every 200 sq. m of the area. Cut the square with a knife diagonally across the square. Rip the coating and check the coating’s thickness with vernier callipers, to see if the dry film has an average thickness of 1 mm. This should be done in every 200 m2.over the entire roof. Once these tests are done, reapply New coat over these portions, in accordance with the Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP. all as specified and directed
M&L for preparation of existing surfaces to remove all dirt, mildew and other contaminants. Treating areas affected by Algae, moss or fungal growth with biocide wash solution and pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely. All surface cracks up to 5 mm width shall be filled up with Dr. Fixit Crack-X.Cracks or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP. Separation gaps more than 5 mm should be filled up with Dr. Fixit Pidicrete URP modified mortar or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP. Priming shall be done using Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2parts Prime seal diluted with 1 part water) @ rate of 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. It shall be allowed to dry for 6-8 hrs. One coat of Dr. Fixit Raincoat Waterproof Coating or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be coated without dilution by brush or roller for rain lashing walls at the thickness of 120 – 130 microns all as specified and directed . Note: All above treatment shall be measured as one unit of square metre and paid accordingly.
M&L for apply a tack coat of bitumen 85 /25 at the rate of 1.20 Kg /Sqm on roof surfaces including cleaning of surfaces in patches including sealing the open joints in the water proof felt including one coat solar reflective f aluminium painting @ .10 Lit per sqm on repaired portion complete all as specified and directed
M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B complete all as specified and as directed.
M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surface based materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces complete all as specified and as directed.
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed.
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. Fe-410- W(Gde- E-250) quality- B(cut to ordinary lengths i.e. Within 20mm of the length indicated) complete all as specified and as directed.
Preparation of new steel surfaces and applying two coats of black bituminous paint complete all as specified and as directed.
Cutting holes into or through brick walls but in brick walls superficial area n.exc 150sqcm built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed.
Cutting holes into or through brick walls built in but in brick walls area exc 150 sqcm but n.exc 400 sqcm built in lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed.
Complete removal of existing roof treatment any type and demolition of cement concrete padding at roof slab n exc 15cm thickness complete all as specified and as directed.
M & L for plain cement concrete 40mm thick average thickness as roof padding type B0, 1:2:4 (12.5mm graded aggregate) finished fair and even over concrete surface on roof top, and finished even and smooth with 10mm thick cement plaster in CM 1:4 mixed with WPC @ 200 ml per bag, when the concrete is green all as per manufacturer instructions and as specified and as directed. ( Note: Water proofing compound will be paid under measured separately)
Cleaning and preparation of newly plasters roof surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminous (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed.
Taking down of existing cement or lime plaster along with the existing water proofing treatment on walls and applying 10 mm thick cement plaster 1:3 mixed with liquid Water Proofing Compound @ 200 ml per bag, cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminous (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed.
M&L PCC Type B2 (1:2:4) using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and as directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. Capacity exc 250 ltrs but n.exc 500 ltrs complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. Capacity exc 500 ltrs but n.exc 1000 ltrs complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. Capacity exc 1000 ltrs but n.exc 2000 ltrs complete all as specified and directed.
S&F Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 15mm dia bore complete all as specified and as directed.
S&F Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 20 mm dia bore complete all as specified and as directed.
S&F Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 25 mm dia bore complete all as specified and as directed.
Refixing only Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 15mm dia bore complete all as specified and as directed.
Refixing only Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 20 mm dia bore complete all as specified and as directed.
Refixing only Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 25 mm dia bore complete all as specified and as directed.
M & L Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25 mm dia bore pipes fixed in repairs complete all as specified and as directed.
M & L Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for 20 mm dia bore pipes fixed in repairs complete all as specified and as directed.
S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 500 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 2000 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
PVC (SWR) pipes 110mm single socketed , in any length with rubber ring joints ,fixed to walls /floor ,spouts etc complete including dismantling existing pipes of any description complete all as specified and as directed.
PVC (SWR) bends with oval access door 110mm fixed in repairs complete all as specified and directed complete all as specified and as directed.
YOGAA MANPOWER AGENCY (BID ID -3102105)
G.L.THIRUMALAI NAIDU AND COMPANY (BID ID -3102586)
ARK Enterprises (BID ID -3103696)
Sri Aruna Associates (BID ID -3103230)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .