Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹37.0 L+₹1.1 L (2.97%)Rejected-Finance 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹38.4 L+₹2.5 L (7.00%)Rejected-Finance H NO 114 A 10 GHAZI NAGAR RADDI CHOWKI GOHALPUR JABALPUR MP | L3 | Rejected-Finance Third Lowest amount quoted | |
| 4 | L4₹40.7 L+₹4.8 L (13.4%)Rejected-Finance 316 A VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L4 | Rejected-Finance Fourth Lowest amount quoted | |
| 5 | L5₹41.4 L+₹5.5 L (15.4%)Rejected-Finance 403 NARSINGH NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | JABALPUR | MP | 482005 | L5 | Rejected-Finance Fifth lowest amount quoted |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
5 Oct 2024, 6:00 pmClosed
Lt Col P Aditya Deepak, GE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
REPAIR TO DRAIN, CULVERT, COMPOUND WALL, FENCING, GATE IN ZONE C AREA UNDER AGE B/R-I OF GE (EAST) JABALPUR
2024_MES_673817_1
8665/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (East) Jabalpur
class D category a(I)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹98,000
Yes
30 Nov 2024
11 Sept 2024
8 Oct 2024
11 Sept 2024
5 Oct 2024
21 Sept 2024
11 Sept 2024 - 18 Sept 2024
Amount
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of MS 'C' channel, angle iron, MS plate, Nut & Bolt etc for water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F Mild Steel framed work as in doors or gates (Ornamental/ Design type ) of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering in Fe 410-W (Gde- E- 250) quality-A . Doors, etc. to be prepared for hanging or sliding with and including either hooks and pintle hinge or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; incl errection and fabrication also fastening and fixing complete all as specified and directed.
S&F fpr posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting/welding, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Dismantling fencing wire mesh/chain link any type and any size complete all as sepcified and directed.
Supply only chain link MS galvanized fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Excavating in post holes or single holes each n. exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc. 25 cm watering and removing surplus soil to a distance n. exc 50 m and making good surface of any type of soil complete all as specified and directed.
M&L for cement concrete 1:3:6, type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:2:4, type B2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches etc complete
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
M&L for cement concrete 1:4:8, type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter rough finished surfaces of concrete complete all as specified and directed.
M&L for RCC nominal mix 1:2:4 type B1 (20 mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams bases for column etc basement slabs under reamed piles and mass concrete complete all as specified and directed.
M&L for form work to sides of pillars, posts, struts, piers, columns and stanchians to rough finished surfaces of concrete complete all as specified and directed.
M&L for RCC nominal mix 1:2:4 type B1 (20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete completed all as specified and directed.
M&L RCC 1:2:4 nominal mix (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L TMT bars 10 mm dia and over cut to length, bent to shape required incliding cranking, bending spirally for hooking ends and binding with and including mild steel (annealed) wire not less than 0.90 mm dia complete all as specified and directed.
All as per above item above but 8 mm dia and above upto 10 mm dia as in stirrups, spacers and binders complete all as specified and directed.
M&L for old size bricks with fly ash bricks straight or curved on plan exc. 6m mean radius and setting in cement mortar 1:6 etc. complete all as specified as directed.
M&L except brick work with old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius obtained from the demolition and built in CM 1:6 complete all as specified and directed.
Rendering 10mm thick in CM 1:6 on conc surfaces finished even and fair without using extra cement complete all as specified and directed.
M&L for providing precast cement concrete type B-0 (1:2:4) (12.5mm graded aggregate) as in louvers and jallies, 50mm thick (measured solid) set CM 1:4, including all mouldings but excluding frame complete all as specified and directed.
M&L PCC (1:2:4) type B-1 (20mm graded stone aggregate) as in kerbs/coping and the like including weathering, slightly rounded or chamfered angles and throating, including formwork complete all as specified and directed
M&L for cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel not exc 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4 type B-1 using 20 mm stone aggregate as in cover slabs (any type) and similar work round square or rectangular in shape and set in CM 1:4 complete all as specified and directed.
M&L for 300mm dia reinforced cement concrete pipe class NP-2 laid and jointed complete with collars complete all as specified and directed.
M&L PCC 1:4:8 type D2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 300 mm bore complete all as specified and directed.
S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed each line wire to be measured) complete all as specified and directed.
M&L for mild steel bolt machine made with hexagonal or square beads at one end and screwed the other or screwed both ends each screwed and to be fitted with washers and one hexagon or square but length of bolt exc 5 cms but not exceeding 10cm long dia shall be of 5 to 10mm dia complete all as specified and directed.
M&L preparing new steel surfaces and applying two coat of synthetic enameled paint over a red oxide primer exc 10 cm width or girth complete all as specified and directed.
M&L for painting to steel and iron surfaces of any description, over 10 cm width or girth, not otherwise described with two coats of black bituminous paint over a coat of red oxide primer including preparation of surfaces complete all as specified and directed.
M&L preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Returning filling in including, spreading, levelling watering and well ramming in layers n. exc 25 cm thick complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floor and pavings n.exc 15cm thickness (below or above GL) complete all as specified and directed.
M&L for PCC 1:4:8 type D2, 75mm thick using 40mm graded aggregate as in sub base complete all as specified and directed.
M&L for PCC 1:2:4 type B1, 100mm thick using 20mm graded aggregate and finish the surface even and smooth without using extra cement complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L 80 mm thick factory made rubber made glossy finish machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of M-40 grade complete all as specified and directed.
M&L 60 mm thick factory made rubber moulded glossy finish machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of M-35 grade complete all as specified and directed.
S&F factory made rubber moulded glossy finished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
Schedule of credit amount of Rs. 1,51,900.00 to be deducted during AOC.
a k builders (BID ID -3119596)
HAFEEZ CONSTRUCTION (BID ID -3119436)
M/S A.P.M. CONSTRUCTION CO. (BID ID -3119336)
LAL SINGH & SONS (BID ID -3129551)
M/s PARASRAM MULCHANDANI (BID ID -3118877)
RAGHAVAY CORPORATION (BID ID -3119365)
SHRI KRISHNA CONSTRUCTIONS (BID ID -3117099)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .