Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAdmitted-Finance 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | ₹39.2 L | L1 | Admitted-Finance |
| 2 | L2₹43.9 L+₹4.7 L (11.9%)Admitted-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹43.9 L+₹4.7 L (11.9%) | L2 | Admitted-Finance |
| 3 | L3₹46.0 L+₹6.8 L (17.4%)Admitted-Finance | ₹46.0 L+₹6.8 L (17.4%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Singla Electricals L2 | Soma Enterprises L3 | jassal engineering L1 |
|---|---|---|---|---|---|---|
| 1.00 | Materal and labour for attending day to day street / security light (of any type, wattage and make, installed at various locations of Lalgarh Jattan Mil Stn) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of drivers, Surge Protection Device (SPD), replacement of old unserviceable light fittings/fixtures, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, and properly insulating the connections complete all as specified & directed by the Engineer-in-Charge.
Note :-
(i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of this BoQ .
(ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 08 hours of receipt of complaints.
(iii) contractors manpower shall attend complaint cell at 9.00 AM on dailly and shall get the complaint noted, address the complaints and completion report to given at the enf of the day to JE E/M.
(iv) Vehicle, ladder, tools, LT tapes etc as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement.
(v) Any complaint/job given on a particular day shall be repaired/rectified within eight hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day.
(vi) Old retrieved material shall be deposited in AGE E/M yard. | 800 | Each job | 60 ₹48,000 Lowest | 100 ₹80,000 | 178 ₹1,42,400 |
| 2.00 | Supply only electric driver for 35/45 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge. | 150 | Each | 160 ₹24,000 Lowest | 311 ₹46,650 | 300 ₹45,000 |
| 3.00 | Supply only electric driver for 60 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge. | 150 | Each | 250 ₹37,500 Lowest | 350 ₹52,500 | 300 ₹45,000 |
| 4.00 | Supply only electric driver for 90/100 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge. | 200 | Each | 350 ₹70,000 | 400 ₹80,000 | 150 ₹30,000 Lowest |
| 5.00 | Supply only electric driver for 150/200 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge. | 70 | Each | 550 ₹38,500 | 500 ₹35,000 | 150 ₹10,500 Lowest |
| 6.00 | Supply only surge arrestor of 5KV/10KV for LED type fittings complete all as specified and directed by the Engineer-in-Charge. | 200 | Each | 40 ₹8,000 Lowest | 200 ₹40,000 | 300 ₹60,000 |
| 7.00 | Supply & fixing in repairs Automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take three phase load of 8KW, Contactor Rating 25-32Amps, MCB SP 32Amps, complete all as specified and directed by the Engineer-in-Charge. | 10 | Each | 17,000 ₹1,70,000 | 10,000 ₹1,00,000 Lowest | 22,000 ₹2,20,000 |
| 8.00 | Supply and fix in repair to Nature Switch smart sensor operational voltage range 120-440V , 50 Hz output load rating 5 Amps switching endurance more than 5000Cycles , Device power consumption less than 1Watt, IP rating 65 complete all as specified and directed by Engr in charge. Make :- L&T, Legrand, Havells, Schnieder , Kakatiya. | 5 | Each | 6,000 ₹30,000 | 3,497 ₹17,485 Lowest | 6,000 ₹30,000 |
| 9.00 | Supply and fixing in repair 3 pole power contactor type ML 3 AC 3 rating(100A) Aux Contactors 2NO+2NC compatible with digital timer of suitable capacity complete all as specified and directed by EIC.Make :- L&T, Legrand, Havells, Schnieder | 5 | Each | 8,500 ₹42,500 | 2,500 ₹12,500 Lowest | 7,000 ₹35,000 |
| 10.00 | Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as apecified and directed. | 1,000 | Cum | 150 ₹1,50,000 | 100 ₹1,00,000 Lowest | 120 ₹1,20,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Aug 2026, 6:00 pmClosed
GE LALGARH JATTAN
GE LALGARH JATTAN - 335037, RAJASTHAN
REPAIR, REPLACEMENT OF STREET, SECURITY LIGHTS AT OTM LALGARH JATTAN MIL STN UNDER GE LALGARH JATTAN
2026_MES_781579_1
8937-18/GE/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE LALGARH JATTAN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE LALGARH JATTAN
₹80,000
Yes
7 Sept 2026
29 Jul 2026
26 Aug 2026
29 Jul 2026
24 Aug 2026
12 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Materal and labour for attending day to day street / security light (of any type, wattage and make, installed at various locations of Lalgarh Jattan Mil Stn) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of drivers, Surge Protection Device (SPD), replacement of old unserviceable light fittings/fixtures, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, and properly insulating the connections complete all as specified & directed by the Engineer-in-Charge.
Note :-
(i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of this BoQ .
(ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 08 hours of receipt of complaints.
(iii) contractors manpower shall attend complaint cell at 9.00 AM on dailly and shall get the complaint noted, address the complaints and completion report to given at the enf of the day to JE E/M.
(iv) Vehicle, ladder, tools, LT tapes etc as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement.
(v) Any complaint/job given on a particular day shall be repaired/rectified within eight hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day.
(vi) Old retrieved material shall be deposited in AGE E/M yard. | 800 | Each job | - | - |
| 2 | Supply only electric driver for 35/45 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge. | 150 | Each | - | - |
| 3 | Supply only electric driver for 60 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge. | 150 | Each | - | - |
| 4 | Supply only electric driver for 90/100 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge. | 200 | Each | - | - |
| 5 | Supply only electric driver for 150/200 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge. | 70 | Each | - | - |
| 6 | Supply only surge arrestor of 5KV/10KV for LED type fittings complete all as specified and directed by the Engineer-in-Charge. | 200 | Each | - | - |
| 7 | Supply & fixing in repairs Automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take three phase load of 8KW, Contactor Rating 25-32Amps, MCB SP 32Amps, complete all as specified and directed by the Engineer-in-Charge. | 10 | Each | - | - |
| 8 | Supply and fix in repair to Nature Switch smart sensor operational voltage range 120-440V , 50 Hz output load rating 5 Amps switching endurance more than 5000Cycles , Device power consumption less than 1Watt, IP rating 65 complete all as specified and directed by Engr in charge. Make :- L&T, Legrand, Havells, Schnieder , Kakatiya. | 5 | Each | - | - |
| 9 | Supply and fixing in repair 3 pole power contactor type ML 3 AC 3 rating(100A) Aux Contactors 2NO+2NC compatible with digital timer of suitable capacity complete all as specified and directed by EIC.Make :- L&T, Legrand, Havells, Schnieder | 5 | Each | - | - |
| 10 | Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as apecified and directed. | 1,000 | Cum | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
tender_merged.pdf
Tender Documents • 0.85 MB
BOQ_875562.xls
BOQ • 1.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .