Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹64.3 LAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹69.3 L+₹3.9 L (5.93%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L-2 | Rejected-AOC Being L-2 | |
| 3 | L-3₹72.9 L+₹7.4 L (11.4%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L-3 | Rejected-AOC Being L-3 | |
| 4 | L-4₹80.3 L+₹14.8 L (22.6%)Rejected-AOC | L-4 | Rejected-AOC Being L-4 | |
| 5 | L-5₹81.4 L+₹15.9 L (24.3%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L-5 | Rejected-AOC Being L-5 |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
11 Nov 2022, 6:00 pmClosed
Commander Works Engineer Subs Mumbai
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO MAGAZINE NOS- P-115 (M5), P-116 (M6 ) AND P-117 (M7) AT NAD TROMBAY
2022_MES_552929_1
8827/E8
Open Tender
Civil Works
Item Rate
270 days
NAD TROMBAY
As per eNIT
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹2.0 L
19 Dec 2022
4 Oct 2022
14 Nov 2022
4 Oct 2022
11 Nov 2022
28 Oct 2022
Amount
Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15 cm thick (above or below ground level) and removing the retrieved debris outside MD land, complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. including rolling shutters
Taking down wooden chowkats or frames, not exc 1.5 sqm each with shutters (Without taking of shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces, complete all as specified and directed.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for and removing the retreived debris out side MD land, all as specified and directed.
Demolition of cement concrete (reinforced) from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris out side MD land, all as specified and directed.
Demolition of brickwork/stone boulders built in cement mortar including disposal of debris, etc outside MD land complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed
M&L for Ready mix plaster 10mm thick on faces of bricks or concrete surface including necessary scaffolding upto 24m height, including preparation of wall surfaces etc to receive plaster complete all as specified and directed.
M&L for rendering 5mm thick in ready mix plaster on ceiling surface and finishing the surfaces even and smooth without using extra cement including scrapping down and preparation of ceiling surfaces to receive plaster, scaffolding as reqd etc, complete all as specified and directed.
M&L for Ready mix polimer modified cement based plaster 12mm thick on bricks or concrete surface including dubbing coat to match with existing surfaces with necessary scaffolding upto 24m height including preparation of wall surfaces etc to receive plaster complete all as specified and directed.
Chipping, removing carefully loose/damaged concrete including plastering from RCC surfaces of columns, beams, soffits of slabs etc by low impact Hammer/Breaker without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement using wire/ rotary wire brush, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of approved makes on reinforcement bars with time interval of 6 hr between the coats, and applying approved protective coating complete all as specified and directed.
M&L for approved anticorrosive Treatment to Reinforcement by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed. Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.
M&L for providing steel reinforement with TMT bars of appropirate size where 30% of cross section in various structural RCC members reduced like column, beams and Slab etc. including cutting, bending, fixing the bars, tying with binding wires etc including dismantiling of rusted steel including application of approved rust converter and applying protective coating complete all as specified and directed. Note: This item is applicable for additional bars required in the existing RCC structures.
M&L for Epoxy bond coat of approved make as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from approved manufacturers, upto 20mm thickness while the bonding agent is still tacking, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from from approved manufacturers while the bonding agent is still tacking, exceeding 20mm thickness and not exceeding 40mm thickness in two layers, each layer not exceeding 20mm, including levelling, profiling etc, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 40mm in thickness) with prebatched, prepacked, single component ready to use microconcrete as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper using roller finish over one coat of alkali resistant primer including necessary scaffolding etc. complete all as specified and directed.
M&L for leakage / seepage proof coating consisting of preparing the old surfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of approved chemical as approved by the GE (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system of approved elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed and as required. Notes: (i) The percentage of colours in Camouflaging pattern shall be as under :- Olive Green- 50% Dark Brown 25% Dark Stone/Leaf Brown - 25%.
M&L for preparation of newly plastered surfaces of any description and at any position not otherwise described and applying two coats of acrylic emulsion antifungal paint in camouflage pattern over a coat of acrylic primer including necessary scaffolding etc. complete all as specified and as directed and as required. Notes: (i) The percentage of colours in Camouflaging pattern shall be as under :- Olive Green - 50% Dark Brown - 25% Dark Stone/Leaf Brown - 25%.
All as item No 22.00 above but preparation of existing old treated surface and apply One coat of acrylic emulsion antifungal paint in camouflage pattern all as specified and directed
M & L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer including necessary scaffolding etc. complete all as specified and directed.
M & L for preparation of old plastered surfaces of ceiling and applying one coat of oil bound distemper including necessary scaffolding etc. complete all as specified and directed.
M&L for 75mm thick ready mix concrete M-25 (using 20mm Aggregate) as in flooring, provision of necessary formwork and finishing the surface even and smooth without using extra cement including roughening of existing concrete surface complete all as specified and directed.
M& L forming 35mm thick dummy joints filled with and including pre formed bitiminous filler, top 100mm primed and sealed with sealing compound grade A for 75mm thick floor, complete all as specified and directed.
M& L forming 30mmx10mm deep thick construction joints filled with and including pre formed bitiminous filler, top 100mm primed and sealed with sealing compound grade A for 75mm thick floor, complete all as specified and directed.
M&L for providing 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement, complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates,rails braces etc complete drilled for fixing of steel sheeting or other covering doors etc conforming to Fe -410W Grade - E-250 quality A, complete all as specified and direced
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes, shall be measured and paid separately as supply only under respective item.
S&F mild steel Framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe -290 Grade -E-165, complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm for wooden shutters in any position with and including new wooden beads as required for securing, complete all as specified and directed. Note: Only wire mesh area will be measured.
M&L for Reinforced cement concrete Nominal mix using (1:2:4) concrete as in chajja and like using 20 mm graded stone aggregate complete all as specified and directed
Use and waste of Formwork to chajjas, troughs and similar items including edges for rough finished flat surfaces complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 W (gde E250) quality B complete all as specified and directed.
S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde - E 250) quality - A complete all as specified and directed.
M&L two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface complete all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edge,.complete all as specified and directed.
M&L cement plaster (1:3) with 10mm thick to be finished smooth without using extra cement mixed with WPC @3% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
Supply only integral water proofing compound, complete all as specified and directed.
M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sq cm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%. (d) Over the membrane provide a finishing with solar reflective bitumen aluminium paint @ 0.10 Kg/Sqm as prescibed by manufacturer.
Removing plant/growth including its roots upto 1.00m of plant height at any location/at any storey and of any description and treating the surfaces with Acid (HCL) and making good surfaces with cement mortar 1:4, complete all as specified and directed.
M&L for brick work with sub class B old size bricks and of class designation 35, straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
M & L for Treatment of soil under existing floors using ATT chemical emulsion @ 0.5 litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors all as specified and directed.
M & L for machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed pigment in window cills, jambs,etc complete all as specified and directed including dismantling existing stone slabs.
M & L for Taking down carefully Flame proof fluorescent tube light fitting single/double of any wattage or size or street light fittings complete all as specified and directed by the Engineer-in-charge.
S&F in repairs flame proof WP rotory switch/Isolator 230 Volt 16 A double pole ON/OFF with cable termination box in LMS complete all as specified and directed by the Engineer-in-charge.
S & F CIMFR Certified 2X 20 Watts LED Flame proof Fitting in die cast AI housing with heat resistance toughetned complete with all acessories and including connecting up with three core flexible multi strand copper conductor of 2.5 Sqmm, drawn through steel conduit complete all as specified and directed by the Engineer-in-charge.
S & F CIMFR Certified 60 Watts LED Flame proof Fitting, wellglass in die cast AI housing with heat resistance toughetned complete with all acessories and including connecting up with three core flexible multi strand copper conductor of 2.5 Sqmm, drawn through steel conduit complete all as specified and directed by the Engineer-in-charge.
S&F flame proof weather proof threaded type junction box LM 6 aluminium alloy 2 to 4 way complete all as specified and directed.
S&F flame proof weather proof metallic hose conduit 3/4 " dia 300 mm long complete all as specified and directed.
S&Fix in replacement wall mounted out door type double door LT Panel made out of 3 mm thick CRCA Sheet, the panel shall be provided with flame proof MCB DB made out of Cast aluminium alloy LM6, inside and out side light gray epoxy powder coating shade, 'O' ring endless neoprene rubber gasket, with 1 No. cable entry for incoming cable and three Nos cable entry for out going circuits with and including cable gland and stopping plug, 1 No MCB SPN 32 Amp as incoming and 4 Nos MCB SP 6 to 32 Amps for out going connections IP 65 protection as per IS 2147/1962. The panel shall be powder coated, front openable and lockable with key and shall be fabricated from CPRI approved manufacturer complete all as specified and directed by the Engineer-in-charge.
M&L for flame proof circuit wiring with two single core 2.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade with and including stove enamelled steel conduit laid over the surface of wall/ceiling and PVC insulated 2.5 Sqm single core multi strand copper conductor as continous earth wire in green colour, the cable shall be drawn in through stove enamelled steel conuit and connected to DB, equipments, connector, common earth dolly all as specified in wall, ceiling, steel structures of builiding with necessary saddles & spacers and as directed including taking down of old wiring complete all as specified and directed by the Engineer-in-charge.
M&L for flame proof circuit wiring with two single core 4 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade with and including stove enamelled steel conduit laid over the surface of wall/ceiling and PVC insulated 4 Sqm single core multi strand copper conductor as continous earth wire in green colour, the cable shall be drawn in through stove enamelled steel conuit and connected to DB, equipments, connector, common earth dolly all as specified in wall, ceiling, steel structures of buildings with necessary saddles & spacers and as directed including taking down of old wiring complete all as specified and directed by the Engineer-in-charge.
M&L for earthing complete with Galvanised steel earth plate electrode 600mmx 600mmx 6 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of GI Strip of size 32 x 6 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed and including taking down of old earthing materials. Note: (1). 7.5 RM GI strip is deemed to be included in quoted rates. Beyond 7.5 RM strip shall be measured and paid separately (2). Earth resistance of earth pit should be less than 2 ohms. On testing after completion if the desired earth resistance is not obtained the earthing shall be redone at no extra cost. (3) Rate quoted by the tenderer is deemed to be included salt & Charcoal upto & above 150 mm top of plate.
S&F aluminium earth strip as roof/down/earth continuity conductors of size 32mm x 6 mm with saddles, insulators, screws, etc to / at any position / location of sheds/ buildings of height up to 5 metre complete all as specified and directed by the Engineer-in-charge Note -i) The quoted rate is deemed to be inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 5 metre ii) The rate is deemed to be inclusive of Procealin insulator, screws, Plugs etc as required.
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 4 core including necessary connection and providing cable lugs as required, including taking up old UG cable of any size complete all as specified. Note: Excavation and earth work shall be measured and paid separately under appropriate item in the schedule
Taking down aluminium/copper earth strip of any size laid as roof or down conductors with saddles, etc from any position / location of sheds/ buildings of height up to 30 metre complete including air termination rod complete all as specified and directed by the Engineer-in-charge
S&F aluminium earth strip as roof/down/earth contunity conductors of size 25x3mm with saddles, insulators, screws, etc to / at any position / location of sheds/ buildings of height up to 30 metre complete all as specified and directed by the Engineer-in-charge
Supply and fix GI strip 32mm x 6mm buried in ground complete all as specified and directed by the Engineer-in-charge
M&L for Earth test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mmm drilled and screwed including 3 nos 8mm dia, 25 mm long hex head screw complete all as specified and directed by the Engineer-in-charge
M & L for chemical earthing complete with copper plate electrode 900 mm x 600 mm x5 mm thick buried directly in ground (Earth pit not less than 4.5 Meters deep below normal ground level with top edge of the plate not less than 3.45 mtr below ground level earth plate connected to copper strip 50 x 6mm (drawn in earth lead protection pipe medium grade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 5 of SSR Part I connected to earthing lead, filling with Charcoal 40 KG, common salt 325 KG and Magnesium sulphate 100 KG necessary excavation and earth work in any type of soil Perforated watering pipe, funnel with wire mesh, earth lead protection pipe light grade PCC Chamber 1:3:6 type C (for even finish on both the faces) and RCC Cover 1:2:4 type B1, 550 x 500 x 50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia Steel rod 500 mm Long all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts and including Test point terminal block made of gun metal or phosphorus bronze size 75*75*25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw, fixed inside MS Box with Porcelain insulators etc all as specified and directed.
S&F air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge
M&L for pre-cast cement concrete block of size 0.15M x0.15M x0.15M (for fixing of Aluminium strip) type C1 1:3:6 using 20mm graded stone aggregate in cement mortar 1:4, including fixing the concrete block on terrace for fixing of lightning conductor complete all as specified and directed by the Engineer-in-charge Note -i) The quoted rate is deemed to be inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 metre.
Parmatma Enterprises
Joy builders
S R INFRASTRUCTURE
Vishal Builders
R J ENTERPRISES
M/s Mohd Altaf Hanif Qureshi
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .