Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.0 L+₹28,790 (0.81%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.6 L+₹81,450 (2.28%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.2 L+₹2.4 L (6.81%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹39.8 L+₹4.1 L (11.3%)Rejected-Finance AT PO DERA COLLIERY TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
3 Jul 2023, 6:00 pmClosed
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
SPL REPAIRS TO BLDG. NO. T2 SINGLE OFFR QTRS OF PONNAPA ROAD, ROOF OF OFFRS MD ACCN NO. 3/1 TO P 3/4 AT MP LINE AND CONFERENCE HALL OF CDA AUDIT CAMPUS AT PCDA P UNDER GE W PRAYAGRAJ
2023_MES_601860_1
8627/E8
Open Tender
Civil Works
Item Rate
GE WEST PRAYAGRAJ
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹1 L
Yes
18 Aug 2023
7 Jun 2023
4 Jul 2023
7 Jun 2023
3 Jul 2023
20 Jun 2023
Amount
Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified and directed.
M&L for structural steel work with rolled mild steel sections conforming to Gde Fe- 290 Gde E-165) 'A' quality as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in wall cladding or roof coverings including ridges complete all as specified and directed.
M&L Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
M&L Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
Demolition of brick work or stone masonry, built in cement mortar incl all quoins, pillars etc complete all as specified and directed
M&L for brick work with fly ash bricks old size , straight or curved on plan exceeding 6M mean radius, built in cement mortar 1:6 complete all as specified and directed
All as per srl item No 7 above but except old size sub class 'B' bricks. (Note:- Old bricks retrieved from demolition shall be re-used)
Dismantling, floor hearth or wall tiling including cement mortar bedding and removing rubbish off the premises complete all as specified and directed.
M&L for joint free non skid, ceramic “coloured” tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L joint free vitrified ceramic coloured tiles (dark shade) of 7 to 8mm thick area of each tile exceeding 0.18 and n.exc 0.36 Sqm in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L for Vitrified Ceramic coloured tiles (dark shade) 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.18 and n.exc 0.36sqm , in dado / skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for double charged Vitrified Ceramic coloured tiles (dark shade) 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.18 and n.exc 0.36sqm , in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Glazed ceramic coloured tiles 7 to 8mm thick area of tile exceeding 0.11 and n.exc 0.18 Sqm in skirting, dados, risers to steps, etc set and jointed in neat cement slurry, and pointed in coloured cement to match tiles over and including 10mm thick rendering or backing layer in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick work, concrete surfaces with WPC (liquid form) finished even and fair without using extra cement complete all as specified and directed
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, concrete surfaces with WPC (liquid form) finished even and fair without using extra cement complete all as specified and directed
M&L preparation of existing old plastered surfaces including removal of existing treatment and applying two coat of Dr. fixit sure seal damp proof chemical or Smartcare hydroloc water proofing of make Asian on plastered surfaces complete all as specified & as per manufacturer's instructions.
M&L for preparing of newly plastered wall surface and applying two coats of cement base paint over a coat of cement wash complete all as specified and directed.
M&L for preparation of new plastered surfaces, applying white cement based wall care putty(Birla/JK white) on the surfaces with minimum 2 to 3 mm uniform thickness making surface absolutely smooth by grinding with sand paper and applying two coats of oil emulsion distemper over a coat of primer of approved shade on surface of wall complete all as specified and directed.
M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coat of white wash on old surface of wall complete all as specified and directed.
M&L for preparation of old distempered surface of wall including cornices etc. by washing, rubbing down, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and stopping of distempered surfaces and applying one coat of oil emulsion distemper of approved shade on surface of wall complete all as specified and directed.
M&L for removal of existing treatment from wall by mechanical means & applying white cement based wall care putty(Birla/JK white) on the surfaces with minimum 2 to 3 mm uniform thickness making surface absolutely smooth by grinding with sand paper and applying Two or more coats of 100% Premium acrylic emulsion paint having level of volatile organic compounds less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.
M&L for preparation of old painted surface of wood and wood based materials by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and directed.
M&L for preparation of old painted surface of steel and iron by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and directed.
M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coat of Cement Base Paint white or tinted of approved shade complete all as specified and directed.
Taking down door chowkhat with shutter area not exceeding 1.5 Sqm each (without taking off shutters from the frame) complete all as specified & directed.
Taking down chowkhat or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified & directed.
Taking down shutters of wooden or aluminium door of any description n. exc 1 sqm each complete all as specified & directed.
Taking down shutters of wooden or aluminium door any description area exc 1 sqm and n exc 2 sqm each complete all as specified & directed.
Taking down & refixing wooden or aluminium door shutters of any description not exceeding 1 Sqm each in the same opening after taking down, easing and adjusting including refixing builders hardware, glass etc as required and renewal of unserviceable screws complete all as specified & directed.
Taking down & refixing wooden or aluminium door shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each in the same opening after taking down, easing and adjusting including refixing builders hardware, glass etc as required and renewal of unserviceable screws complete all as specified & directed.
S&F Anodised aluminium frame powder coated for doors, windows, ventilators, partition, posts to sustain curtain rail etc with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F Anodised aluminium door powder coated shutters, aluminium section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door, hinges, anodised aluminium snap beading screws with provision of double action floor spring etc complete all as specified and directed.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and handling removing to store or stacking for reuse complete all as specified and directed.
M&L for 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane complete all as specified and directed
S&F in repair for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for preparation of new steel surface and apply two coats of synthetic enamel paint over a coat of red oxide over 10 cm in width or grith complete all as specified & directed..
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection complete all as specified and directed.
Dismantling carefully 4mm thick ceiling boards to facilitate the replacement of AC sheet with E- Board tile 4 mm thick complete all as a specified and directed.
S&F 4mm thick E-boards tiles false ceiling with powder coated GI snap grid frame work complete all as specified and directed including all necessary drilling, cutting, making good and necessary arrangement to fix electrical items as under:- (a) 25x25x1.5mm thick GI angle powder coated plugged @ 600mm centre to centre along perimeter of wall. (b) 25x25x1.5mm thick GI tee powder coated as main and cross runners suspended with 1.6mm dia GI wire suspenders with adjustable clamps and dash free fastners plugging in RCC slab placed @ 600mm centre to centre from perimeter of wall. (c) Fixing of 4mm thick E-boards tiles of size 595x595mm of approved texture and finished complete with two coats of oil emulsion distemper on ceiling.
Fixing of 4mm thick E-boards tiles of size 595X595mm of approved texture and finish complete with one coat of oil emulsion distemper on ceiling. NOTE: The material obtained from item no. 41
S&F anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605 mm consisting of main and cross tee of size 36.5 x 25 x 1.4 mm weighing 0.24 Kg per RM and 23.5 x 26.4x 1.4 mm weighing 0.191 Kg per RM respectively including supporting hangers 6 mm dia G.I (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of G.I. flat iron 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long complete all as specified & directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing with solvent on to wall to make PVC frame as per specifications complete all as specified and directed.
S&F solid PVC wall lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and directed.
S&F 18-20mm thick granite (of any type) stone slab work (table rubbed and polished) as in windows and doors and including 20mm thick screed bed in cement mortar 1:6 set in white cement with pigment and pointed in white cement 1:2 using marble dust with admixture of pigment to match with shade including cutting in granite slab of desired size and shape including rubbing and polishing and making sandwich moulding to edges complete all as specified and directed. (Note - Breakage if any in granite slab will be born by the contractor).
Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified & directed.
S&F false ceiling at all height with 10 mm thick fully perforated square edged GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595 X 595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)- 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per Sqm including both sides) comprising of main -T runners of size 15X32mm of length 3000mm, cross -T of size 15X32mm of length 1200mm and secondary intermediate cross-T of size 15X32mm of length 600mm to form grid module of size 600X600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80grams per sqm) i.e. 50mm long, 8mm outer dia M-6 dash fasteners, 6mm dia fully threaded hanger rod up to 1000mm length and L-shape level adjuster of size 85X25X2 mm. Galvanized iron perimeter wall angle of size 24X24X0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws complete including taking out existing false ceiling all as specified & directed. The work shall be carried out as per manufacturer's instructions , specifications & drawing and as directed by Engineer-in- Charge
Dismantling of brick tiles any thickness laid on terracing tiles single layer bedded in cement mortar on roof including removal of old tarfelt from site to outside the premises complete all as specified and directed. Note:- Cost of scaffolding and its removal deemed to be included in quoted rate.
Demolition of concrete (un-reinforced) of any description and in any position from the top of roof etc complete all as specified & directed.
Removing of surplus demolished materials to a distance exceeding 250m but not exceeding 1.5 Km and deposited where directed at a level n exc1.5 m complete all as specified and directed. Note: Demolished material should not be thrown away on the ground from the top of roof, it should be removed from the roof by manually or by any mechanical means
M&L cutting crack to 'V' groove section in existing roof cleaning out wetting grouting with cement and sand slurry of 1:3 complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4, type B0 using 12.5 mm graded stone aggregate as in roof kerbs / benching / coving and roof padding over roof surfaces etc rounded or chamfered on edges complete all as specified & directed.
M&L for preparation of existing roof surfaces and roof treatment with reinforced elastomeric liquid waterproofing membrane of 400-micron thickness in four layer(100 micron each layer) having SRI of 1 30, tested as per ASTM E 1980 (with Solar Reflectance and Thermal emittance tested as per ASTM C 1549 and ASTM C 1371 , respectively). The coating should have water absorption less than 1% as per IS: 101 (P-7/Sec-1) 1989, with the ability to resist heat upto 120 00 as per IS: 101 (P-7/Sec-3) 1990 having volatile organic compounds less than 50 gm/litre as per ASTM D 3960 and should have excellent resistance to transmission of ponded water up to 2.5 bars of pressure for 7days. It should also be resistant to Ammonia solution, Sodium nitrate, Sodium hydroxide, along with water and soap solution as per IS: 101 (P-7/Sec-2)1990. The waterproofing membrane will be laminated with 25-40 micron thick transparent Nano modified composite crosslinking polymeric coating with a minimum of 40% solid content as per IS: 101 (P -8/Sec6)1993 and also should pass Impact test as per IS: 101 (P-5/Sec-3) 1988 along with having dust and water repellent & anti-graffiti property passing scratch hardness test of 500g as per IS: 101 (P-5/Sec-2) 1988. It should also pass Cross Cut Adhesion test as per IS: 101 (P-5/Sec-2) 1988. The Polymeric coating should have a self cleaning and easy-to-clean property with excellent weather stability and DPR (Dirt pickup ratio). Surface preparation includes pressure wash cleaning to remove all dust, fungus, etc. The work will be done under the supervision of the Engineer-in-charge by Graco airless machine. The coating thickness and the methodology of application shall strictly be carried out by the authorised vender/ manufacturers with all specifications and as approved by GE. (Make: Dr. fixit, Pidilite, Sika, Star shield) Note :- Roof treatment shall be carried out by the manufacturer in presence of the Engr-in-charge. The manufacturer shall give a guarantee for the performance & durability for 10 years. Tenderer is deemed to quote the rate accordingly.
M&L for 10 mm thick rendering on roof surface with cement mortar in CM 1:3 as per manufacturer's instruction laid in roof etc complete all as specified & directed.
Dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres complete all as specified and directed.
Refixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position including connecting up pipes complete.
S&F rotational moulded, multilayer HDPE water storage tank (white colour three layer) of 1000 ltrs capacity(Cylindrical vertical with closed top) ISI marked fixed in position on existing places with fittings and refixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed.
S&F rotational moulded, multilayer HDPE water storage tank (white colour three layer) of 500 ltrs capacity(Cylindrical vertical with closed top) ISI marked fixed in position on existing places complete and refixing of inlet, outlet & overflow pipe etc, complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 25 mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 20mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.
Refixing old 20mm dia bore steel water tubing & connection with new fitting in new or old position fixed to wall, ceiling or laid in floors complete all as specified and directed.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 25 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.
Refixing old 25 mm dia bore steel water tubing & connection with new fitting in new or old position fixed to wall, ceiling or laid in floors complete all as specified and directed.
S&F Steel water tubes, light grade, ISI marked, galvanised, 25 mm bore with all fittings, fixed to walls and ceiling or laid in floors as over flow pipe of over head tank complete all as specified and directed.
S & F in repair Gun-metal, globe or gate valves, 25mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in repair Gun-metal, globe or gate valves, 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for Preparation of old surfaces of wall and applying one coat of cement based paint complete all as specified and directed.
Taking down carefully unserviceable/damaged copper/aluminium surface (batten/conduit or casing caping) point wiring of any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) including making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
M&L for point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and modular metal flush sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with modular white cover plate with frame of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar (1:4) and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/Exhaust fan/ bell point etc complete all as specified and directed. Note : (a) Switch/bell push/fan regulator etc will be measured and paid separately (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surfaces. (c) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire
All as per Sl Item No. 72 above but for switch socket outlet 3 pin 6 Amps point on independent board controlled by one switch 5Amps, one way complete all as specified and directed.
All as per Sl Item No. 72 above but for switch socket outlet 3 pin 5 Amps point on the same board controlled by one switch 5 Amps, one way complete all as specified and directed.
All as per Sl item No. 72 above but for one 15 Amp socket outlet point using 2.5 Sqmm FRLSH cable.
S&F modular switch, flush type, single pole, one way, 5 amps 230 volts white finish, ISI marked complete all as specified and directed.
S&F modular socket outlet, 5 pin, 5 Amps flush type, 230 volts AC, ISI marked complete all as specified and directed.
S&F modular switch, flush type, single pole, one way, 16 amps 240 volts white finish, ISI marked complete all as specified and directed.
S&F modular socket outlet, flush type, single pole, one way, 6/16 amps 230 volts white finish, ISI marked complete all as specified and directed..
S&F modular bell push switch, single pole, one way, 5 amps 230 volts white finish, ISI marked complete all as specified and directed.
S&F call bell ding dong AC 230 volt, ISI marked complete all as specified and directed.
S&F modular fan regulator 240 V electronic type 2 module complete all as specified and directed.
Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F Ekinox³ TPN DB-VTPN DB 6 way DPX³ 160A MCCB Double door DB's As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase, With 2 Neutral bar, 2 Earthbar and Cable ties for Cable management, Fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Prefitted masking sheet, Reversible Door for IP 43 & IP 54 dB's, With provision for DPX³ 160 MCCB as incomer and SP/TP MCB's as outgoing [IP 4 -IK 09 with metal door complete all as specified and as directed. Make:L&T Cat no DBPSG004SD or equivalent in Legrand / ABB / Havells
S&F in replacement of worn out control switch with MCCB Triple pole, Type- DU 100H having thermal release range 160 Amps, Breaking capacity-30 KA at 415 VAC, 50 Hz conforming to IS 13947 (p-2) with extended/spreader terminal (set of six) including making electrical cable connections with providing proper size of aluminium lugs with due care complete all as specified and directed.
S&F sheet metal enclosure DB for MCB's 240 volt 8 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole 5 to 32 Amps, 240 volts, ‘B’ curve, 10 KA complete all as specified and directed.
S&F MCB single pole & neutral, 40/63 Amps, 240 volts 'C' curve 10 KA complete all as specified and directed.
M&L for concealed sub main wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 4.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm with all fittings and accessories, along with one run of PVC insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor complete including taking down of existing sub main wiring complete all as specified and directed. Note : (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surfaces
M&L for concealed sub main wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable two single core of size 6.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm with all fittings and accessories, along with one run of PVC insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor complete all as specified and directed. Note : (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surfaces
Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
S&F ceiling light with environmental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat pt No: PLUTONEO2X2PLR42WLED857S of make Havells 'or' RC380B LED36S-4000 G4 L60 W60 PSD OD WH OC of make Philips 'or' LCTTLRP-36-FO-CDL of make Crompton
S&F surface / wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat Part No for batten:- REGALBATTENT8UPTO1X18WDSBSWH of make Havells 'or' IGP161LT8-16 of make Crompton 'or' TMC501 P 1xT-LED 22W P3241 of make Philips Cat Part No for Tube light:- PHOTANULTRA2.01213T8SSTL18WLED865SPC of make Havells 'or' LTT8-20 of make Crompton 'or' MAS LED tube 1200MM 18W865 T8 I-2100 lm of make Philips
S&F energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat part No: -LUMILINEPLUSSBS10WLED865SPCSS of make Havells 'or' BN 021 LED10S- 6500 PSU GR S1 of make Philips 'or' LDL-10-WW of make Crompton
S&F LED light fitting 10 Watt bulkhead luminaires in high pressure die cast aluminium housing, lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Cat Part No - WT140 LED7S NW PSU S1 PC; Vista glow of make - Philips 'or' LBHP-10-CDL of make Crompton 'or' LW07-11-XXX-57-XX of make Wipro
Taking down fan, sealing cable end, dismantling blades and removing fan and blades, oiling, greasing and painting of ceiling fans complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. incl Hanging and connecting up including provision of cable from ceiling rose or connector to fan as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate 60cmx60cmx6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to earth lead GI 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade, including protection pipe GI medium grade 15mm bore for earthing lead, wire mesh, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover and frame all as shown in electric plate of SSR part-I (2009), including testing on completion all as directed.
S&F sheet metal enclosure DB for MCB's 240 volt 12 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
M&L for concealed sub main wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable four single core of size 16.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm with all fittings and accessories, along with one run of PVC insulated, unsheathed, stranded copper conductor of size 10.0 Sqmm (green colour) as earth continuity conductor complete all as specified and directed. Note : (i) four runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surfaces
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
Minakshi Construction
YASH ENTERPRISES
M/S PRAGATEE ENTERPRISES
M/S A P CONSTRUCTION
M/S JAI DURGA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .