Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹14.1 L+₹83,161 (6.28%)Admitted-Finance JOGI LANKAR RAINAWARI JOGI LANKAR RAINAWARI LANKAR RAINAWARI LANKAR RAINAWARI SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L2 | Admitted-Finance | |
| 3 | L3₹14.8 L+₹1.5 L (11.6%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹14.8 L+₹1.5 L (11.7%)Admitted-Finance 211 KRALPORA BUDGAM JAMMU KASHMIR 191113 UDYAM JK 04 0011111 | BUDGAM | JAMMU AND KASHMIR | 191113 | L4 | Admitted-Finance | |
| 5 | L5₹15.0 L+₹1.8 L (13.4%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S QADRI ELECTRICALS L2 | MIR IRFAN ELECTRICAL/SUPPLIERS L7 | AL HASSAN ASSOCIATES L8 | m/s paul engineering constructions L5 | AL FALAH ELECTRICAL WORKS L1 | NADEEM ENTERPRISES L3 | M/S WANI ELECTRA & SUPPLIERS L4 | M/S HIBBA ELECTRICALS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Supply. Installations, testing and commissioning of 250KVA, 11/0.433kV, 3-phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Copper wound for 250kVA ), and with LV Cable Box having detachable Aluminium Gland plate. Transformer should have arrangement for vertical Take off. 250 kVA X-mer without OCTC. | 1 | No | 6,50,000 ₹6,50,000 | 7,20,000 ₹7,20,000 | 6,20,000 ₹6,20,000 | 6,00,000 ₹6,00,000 Lowest | 7,00,000 ₹7,00,000 | 8,00,000 ₹8,00,000 | 7,30,000 ₹7,30,000 | 8,45,000 ₹8,45,000 |
| 1.02 | Supply. Installations, testing and commissioning of 100KVA, 11/0.433kV, 3-phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Al. wound) with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. (X-mer without OCTC (Off Ckt Tap Changer)) | 1 | No | 1,85,000 ₹1,85,000 Lowest | 2,10,000 ₹2,10,000 | 2,00,000 ₹2,00,000 | 1,90,000 ₹1,90,000 | 2,04,000 ₹2,04,000 | 2,16,000 ₹2,16,000 | 3,25,000 ₹3,25,000 | 2,27,000 ₹2,27,000 |
| 1.03 | Supply. Installations, testing and commissioning of 11kV Gapless Surge Arrestor, 9 kV, 10 kA, LA with polymer housing, Stn. Type | 2 | Set | 9,000 ₹9,000 | 5,600 ₹5,600 | 10,000 ₹10,000 | 8,000 ₹8,000 | 4,000 ₹4,000 | 3,000 ₹3,000 Lowest | 6,000 ₹6,000 | 3,000 ₹3,000 Lowest |
| 1.04 | Supply. Installations, testing and commissioning of11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type | 2 | Set | 24,000 ₹24,000 | 21,000 ₹21,000 | 18,000 ₹18,000 | 24,000 ₹24,000 | 19,000 ₹19,000 | 16,400 ₹16,400 | 6,000 ₹6,000 Lowest | 16,000 ₹16,000 |
| 1.05 | Supply. Installations, testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A | 2 | Set | 8,400 ₹8,400 | 7,000 ₹7,000 | 12,000 ₹12,000 | 9,600 ₹9,600 | 7,000 ₹7,000 | 3,600 ₹3,600 Lowest | 6,000 ₹6,000 | 4,000 ₹4,000 |
| 1.06 | Providing and laying of 120mm² Single core Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type | 44 | Mtr | 13,200 ₹13,200 | 7,920 ₹7,920 | 30,800 ₹30,800 | 15,400 ₹15,400 | 15,840 ₹15,840 | 10,560 ₹10,560 | 4,400 ₹4,400 Lowest | 8,800 ₹8,800 |
| 1.07 | Providing and laying of 25 sq mm² (2 Ckt for 250 kVA) Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type | 44 | Mtrs | 4,840 ₹4,840 | 8,800 ₹8,800 | 13,200 ₹13,200 | 6,600 ₹6,600 | 11,000 ₹11,000 | 4,840 ₹4,840 | 3,520 ₹3,520 Lowest | 4,400 ₹4,400 |
| 1.08 | Supply. Installations, testing and commissioning of 9 Mtr. Long Pole, (ST-410 SP33) | 4 | No | 64,000 ₹64,000 | 72,400 ₹72,400 | 74,000 ₹74,000 | 74,000 ₹74,000 | 63,200 ₹63,200 | 56,000 ₹56,000 | 48,000 ₹48,000 Lowest | 56,000 ₹56,000 |
| 1.09 | Providing and fixing of 11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting | 6 | No | 3,900 ₹3,900 | 1,800 ₹1,800 | 3,300 ₹3,300 | 3,000 ₹3,000 | 1,800 ₹1,800 | 1,380 ₹1,380 | 600 ₹600 Lowest | 1,800 ₹1,800 |
| 1.10 | Providing and fixing of Channel/Angle/Flat of sizes including clamps | 700 | Kgs | 98,000 ₹98,000 | 92,400 ₹92,400 | 1,12,000 ₹1,12,000 | 91,000 ₹91,000 | 80,500 ₹80,500 | 84,000 ₹84,000 | 68,600 ₹68,600 Lowest | 84,000 ₹84,000 |
Tender Value
₹20.4 L
EMD Value
₹40,900
Closing Date
17 Sept 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer EDI
Office of Executive Engineer EDI
Creation of 250KVA 100KVA Substations at transit accommodation for Kashmiri Migrant at Zewan
2026_PDD_323250_1
E-NIT No 036/EDI
Open Tender
Electrical and Maintenance Works
Turn-key
30 days
Office of Executive Engineer EDI
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
Convener, purchase committee, Directorate of ISM
₹40,900
Yes
26 Sept 2026
2 Sept 2026
18 Sept 2026
2 Sept 2026
17 Sept 2026
2 Sept 2026
2 Sept 2026 - 16 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply. Installations, testing and commissioning of 250KVA, 11/0.433kV, 3-phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Copper wound for 250kVA ), and with LV Cable Box having detachable Aluminium Gland plate. Transformer should have arrangement for vertical Take off. 250 kVA X-mer without OCTC. | 1 | No | - | - |
| 1.02 | Supply. Installations, testing and commissioning of 100KVA, 11/0.433kV, 3-phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Al. wound) with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. (X-mer without OCTC (Off Ckt Tap Changer)) | 1 | No | - | - |
| 1.03 | Supply. Installations, testing and commissioning of 11kV Gapless Surge Arrestor, 9 kV, 10 kA, LA with polymer housing, Stn. Type | 2 | Set | - | - |
| 1.04 | Supply. Installations, testing and commissioning of11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type | 2 | Set | - | - |
| 1.05 | Supply. Installations, testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A | 2 | Set | - | - |
| 1.06 | Providing and laying of 120mm² Single core Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type | 44 | Mtr | - | - |
| 1.07 | Providing and laying of 25 sq mm² (2 Ckt for 250 kVA) Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type | 44 | Mtrs | - | - |
| 1.08 | Supply. Installations, testing and commissioning of 9 Mtr. Long Pole, (ST-410 SP33) | 4 | No | - | - |
| 1.09 | Providing and fixing of 11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting | 6 | No | - | - |
| 1.1 | Providing and fixing of Channel/Angle/Flat of sizes including clamps | 700 | Kgs | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.13 MB
SBD036.pdf
Other Document • 0.86 MB
TECH036.pdf
Other Document • 13.03 MB
BOQ_1087304.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .