Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC 1ST FLOOR P R COMPLEX AT ROAD GUWAHATI 781 001 | KAMRUP METRO | ASSAM | 781001 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹27.1 L+₹2.2 L (8.91%)Rejected-Finance R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L2 | Rejected-Finance Other than L1 | |
| 3 | L2₹27.2 L+₹2.3 L (9.19%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 4 | Not Admitted-Fee/PreQual/Technical SANTIPUR HILL SIDE PS BHARALUMUKH GUWAHATI 781 009 | KAMRUP METRO | ASSAM | 781009 | - | Not Admitted-Fee/PreQual/Technical Others-Due to adverse remarks in WLR for QE Mar 2023 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015, Tele 0361 - 2840127
Repair/ maint of electrical plants/ eqpts and other allied works at 14 BRD, AF and 19 Wing, AF under GE (AF) Borjhar
2023_MES_620501_1
8362/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Borjhar
MES Contractor enlisted as Class E category a (i) having deposited Standing Security of Rs 50,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹50,000
Yes
4 Dec 2023
25 Sept 2023
27 Oct 2023
25 Sept 2023
23 Oct 2023
9 Oct 2023
Amount
Taking down defective Servo Voltage Stabilizer of 200 KVA capacity (Oil Cooled) at site after disconnecting all electrical connection and transportation to workshop for repair works . Location:- 14 BRD, Make:-Servo make india Ltd.
Taking down defective Servo Voltage Stabilizer of 75 KVA capacity (Oil Cooled) at site after disconnecting all electrical connection and transportation to workshop for repair works .Location:- Signal Section,746 SU (AF NET ROOM),59 SQN Inside Hanger,Signal Section near HQ Make:-Volina/Vintek/Vintec electronic Laboratory.
Taking down defective Servo Voltage Stabilizer of 30 KVA capacity (Air Cooled) at site after disconnecting all electrical connection and transportation to workshop for repair works . Location:- 16AFDC,Zironi 19 Wing,PTT/LTT Bldg 19 Wing Make:-Volina/Vintek/Vintec electronic Ltd.
Supply and fixing in repair of Servo control Panel(As per Existing site requirement) with all components all as directed by Engr-in-charge.
M&L for filling the Voltage stabilizer 200, 150, 100 KVA or any type of capacity) with new transformer oil [conforms to IS 335 :1993] after following the undermentioned process incl. necessary filtration & dehydration and fill up the level of the required quantity and storing the used oil in empty barrel for re-using it, all as specified and directed. Make-Gulf/ APAR/ IOCL/ BPCL Note: ii) Any other works reqd for replacement of transformer oil is deemed to be included in this rate.
Supply and fixing in repair of Servo control Box( As per Existing site requirement) with all components all as directed by Engr-in-charge.
Supply and fixing in repair of Servo circuit card (PCB As per site requirement) with all components all as directed by Engr-in-charge.
Supply and fixing in repair of Digital Voltmeter(As per existing site requirement) for 30/75 KVA Stabilizer capacity all as directed by Engr-in-charge.
Supply and fixing in repair of Indicator Light ( As per existing site requirement) for 30/75 KVA Stabilizer capacity all as directed by Engr-in-charge.
Supply and fixing in repair of Push Button/Auto Manual Switch/Mcro Switch/Potentiometer/Limit Switch/Lever Switch/Toggle switch for 30/75 KVA Stabilizer capacity all as directed by Engr-in-charge.
Supply and fixing in repair of Digital Ammeter(As per existing site requirement) for 30/75 KVA Stabilizer capacity all as directed by Engr-in-charge.
Supply and fixing in repair of Servo Motor stepless torque (3 Kg/cm) with resistance capacitor network(RC) all as directed by Engr-in-charge.
Supply and fixing in repair of Servo Motor stepless torque (10 Kg/cm) with resistance capacitor network(RC) all as directed by Engr-in-charge.
Supply and fixing in repair of Dimmer-10 Amps(Per Phase) all as directed by Engr-in-charge.
Supply and fixing in repair of Dimmer-20 Amps(Per Phase) all as directed by Engr-in-charge.
Supply and fixing in repair of Dimmer-40 Amps(Per Phase) all as directed by Engr-in-charge.
Supply and fixing in repair of Transformer (Per Phase) for 30 KVA Servo Stabilizer all as directed by Engr-in-charge.
Supply and fixing in repair of Transformer (Per Phase) for 75 KVA Servo Stabilizer all as directed by Engr-in-charge.
Supply and fixing in repair of Transformer (Per Phase) for 200 KVA Servo Stabilizer all as directed by Engr-in-charge.
Taking down burnt isolation transformer of capacity 50/75 KVA from PCC foundation using suitable capacity crane after disconnecting LT cable. Opening the top/Side cover of the transformer, disconnecting and taking out complete core assembly and dismantling it for checking the serviceability of the coil winding, checking the condition of the body, cleaning the inside inclosure and remove sludge/dirt, cleaning the coils limbs, refixing of core, core assy,LT winding connection, terminal studs of LT sides and reassembling of transformer after repairs from authorised workshop , improvement of insulation resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of engr-in-Charge upto 50/75KVA. Note : Copper winding wire shall be measured and paid separately.
M & L for replacement of old copper winding wire with new copper winding wire including all required materials such as copper winding wire, cotton taper etc.
Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through maually.
Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for sand cushioning for protection of lT under ground cable with screen wash sand and punning to proper reqd cover all as specified and directed.
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 35 sqmm 3.5 core (heavy duty), aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 95 sqmm 3.5 core (heavy duty), aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
M&L 50 mm bore GI tubing “light grade” in trenches/ on pole for protection of cables complete all as specified & directed by Engineer-in-charge.
M&L for cable jointing kit for 1.1 KV grade for outdoor end termination heat shrink type joint complete with jointing materail and accessories suitable for 3.5 core PVC/ XLPE armoured aluminium conductor cable of size 25-50 Sqmm complete all as specified and directed by Engr-in Charge.
M&L for cable jointing kit for 1.1 KV grade for outdoor end termination heat shrink type joint complete with jointing materail and accessories suitable for 3.5 core PVC/ XLPE armoured aluminium conductor cable of size 70-120 Sqmm complete all as specified and directed by Engr-in Charge.
M&L for cable jointing kit for 1.1 KV grade for straight through heat shrink type joint complete with jointing materail and accessories suitable for 3.5 core PVC/ XLPE armoured aluminium conductor cable of size 25-50 Sqmm complete all as specified and directed by Engr-in Charge.
M&L for cable jointing kit for 1.1 KV grade for straight through heat shrink type joint complete with jointing materail and accessories suitable for 3.5 core PVC/ XLPE armoured aluminium conductor cable of size 70-120 Sqmm complete all as specified and directed by Engr-in Charge.
Professional charges for load Testing , carrying out preventive maintenance and certification of 2/3 Ton capacity EOT Crane.
Professional charges for load Testing , carrying out preventive maintenance and certification of 5 Ton capacity EOT Crane.
Professional charges for load Testing , carrying out preventive maintenance and certification of 10 Ton capacity EOT Crane.
Shifting charges of Load from one Location to another Location within 2 KM radius through required T&P till completion of testing and finally bring back to its original location after successful testing.
M/s Vishnu Enterprises
KUNDAN ENGINEERS AND BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .