Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical MAHARASHTRA | KOLHAPUR | MAHARASHTRA | 415101 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹23.6 L
EMD Value
₹23,559
Closing Date
4 Mar 2026, 6:55 pmClosed
Executive Engineer Works Dept ZP Parbhani
Works Dept ZP Parbhani
Providing Electrical Installation, Solar System, Solar Water Heater and Solar Street Lights for PHC Building at Pingli. Tq and Dist. Parbhani
2026_PARBH_1281553_1
ZPPBN/WD/eTENDER/466/25-26
Open Tender
Electrical Works
Percentage
180 days
Tq and Dist. Parbhani
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,200
₹23,559
5 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
4 Mar 2026
25 Feb 2026
Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit . DSR I.No. 1.2.1 (new) [PART A]
Supplying and erecting HMS PVC conduit 25 mm dia.with PVC accessories on wall /ceiling as per specification No: WGMA/ CON, para no. 1.1.1. DSR I.No. 1.2.7. [PART A]
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. DSR I.No. 1.2.8.[PART A]
Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW. DSR I.No. 1.3.1 [PART A]
Supplying & erecting green earth wire 1 x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW. DSR I.No. 1.3.1 [PART A]
Supplying and erecting mains with 2 x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.no. 1.3.2. [PART A]
Supplying and erecting mains with 1 x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.no. 1.3.2. [PART A]
Supplying & erecting mains with 2 x 4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW. DSR I.No. 1.3.3. [PART A]
Supplying & erecting mains with 1 x 4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW. DSR I.No. 1.3.3. [PART A]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.1. [PART A]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.2. [PART A]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete . DSR I.No. 1.6.10 [PART A]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. DSR I.No. 1.6.11. [PART A]
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.23. [PART A]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. DSR I.No. 1.6.30 [PART A]
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW. DSR I.No. 1.7.19 [PART A]
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing andrequired accessories as per specification No: WG-PW/SW. DSR I.No. 1.7.20 (NEW) [PART A]
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW DSR I.No. 1.7.26[PART A]
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. DSR I.No. 2.1.22. (New) [PART A]
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. DSR I.No. 2.3.13. [PART A]
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. DSR I.no. 2.4.4. [PART A]
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG- KT/WB. DSR I.No. 2.7.4. [PART A]
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF DSR I.No. 2.10.22. [PART A]
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. DSR I.No. 2.11.4. [PART A]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. DSR I.No. 2.11.6 [PART A]
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.2. [PART A]
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.3. [PART A]
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.7 [PART A]
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.10 [PART A]
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR /MCBDB1 DSR I.No. 5.4.15. [PART A]
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB DSR I.No. 5.5.1. [PART A]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. DSR I.No. 2.10.14 [PART A]
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. DSR I.No. 6.1.12. [PART A]
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB. DSR I.No. 5.4.9. [PART A]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR I.No. 7.1.5. [PART A]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR I.No. 7.1.31. [PART A]
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. DSR I.No. 7.6.9 [PART A]
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materils, testing & recording the results as per specification no. EA-EP. DSR I.No. 9.1.1. [PART A]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP. DSR I.No. 9.1.4. [PART A]
S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. dSR I.No. 13.15.1. [PART A]
Supplying, installing, testing and commissioning of 15 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 45 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG DSR I.No. 4.5.4.
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB DSR I.No. 5.5.1.
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A. dSR I.No. 5.10.27
Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB. DSR I.No. 5.11.17
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. DSR I.No. 6.1.19
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard. DSR I.No. 6.1.20
Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. DSR I.No.6.1.6.
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. DSR I.No. 6.3.5.
Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. DSR I.No. 6.3.14.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR I.No. 7.1.31.
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE. DSR I.No. 7.6.4.
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA. DSR I.No. 9.1.6.
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. DSR I.No. 9.2.2.
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). DSR I.no. 16.3.7.
Supplying and erecting Street light bracket for erection of side entry fitting on pole with 40 mm. dia. ‘B’ class G.I. pipe of required length complete as per specification no. FG-BKT/SLB. DSR I.No. 2.7.9.
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. DSR I.No. 6.1.1.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. DSR I.No. 6.1.19
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard DSR I.No. 6.1.20
Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP. DSR I.No. 8.1.16
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP. DSR I.No. 9.1.4.
Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole). DSR I.No. 16.3.2.
Supplying , installing, testing and commissioning of solar panel comprising high efficiency polycrystalline / multi - crystalline photovoltaic cell 125 WP, necessary clamps and module frame on existing structure complete with following specifications maximum power 125 W, open Temperature range : 40 to 85 degree celsius, Short Circuit Current (ISC) : 7.5AA, Module voltage : 12V, Open circuit voltage (Voc) : 22.22V, Operating (Nominal Voltage : 12V, Operating maximum voltage : 17.59V, Maximum series fuse rating ( A) Voltage: 15.0A, Number of cells : 72(18 x4), dimension : 1490 x 675 x 35(mm), Weight (kg) : 13.0kg, (with warranty 5 years) [NON CSR ITEM]
Supplying and erecting DC Light Emitting Diode Flood light fitting of 12V 30W, including first 6 hr full intensity light output and following 6 hr with half intensity light output, with lumen < 3750 colour temmp 5500L-6500K, colour redening inex > 70, PWM chrge controller efficiency> 90% , LED driver efficiency> 90% , Duty cycle first six hours 100% rest 50% light, LED external optics 145 x 90 degree street light lens, class IP 66, charge controller methodology - three stage battery charge monitoring algorithm, maximum charging current 20Amps, short circuit portection, battery over charge protections, battery deep discharge protection, solar panel dusk to dawn operation NTTV-4V, DTTV-6V, battery low load disconnect voltage 11.2V , battery fill load disconnect voltage 13V, battery constant voltage set point 14.7V, LED indicaton - green of battery not charging PV low, green on battery not discharge, red on : Battery discharge, load disconnect overall dimension - 255 mm x 90mm x 60 mm, overall weight - 1kg and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete (5 year warranty). [NON CSR ITEM]
Supplying, installing, testing and commissioning of lifepo4 battery with capacity of 12.8V-78Ah with 4S15ABMS with max pulse discharge rate 80A, charging current 15A, Life 3000 cycles, Suitable to charge lithium cell with necesary wiring connection, with IP 65 alluminium cabinet with stand and nut bols compelte. stored casing material - alluminium, terminal -MC-4 connector, charge temperature range 0-45C, discharge tem range 20-55 C, storage temp - 20-45C, battery size 198x168x170mm, weight 12kg, nominal voltage -12.8V, nominal capacity - 78Ah, max charging current : 50A, instantaneous dscharge current : 200A, continuous discharge current : 100A, life : 3000cycles, charging temp : .\0.45C, discharge temp : 20-65 C, storage temp : 20-65 C, operating voltage range : 10.0V - 14.6V, overload protection voltage : 14.6v (with warranty 5 years). [NON CSR ITEM]
Supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). DSR I.No. 3.1.7. [PART A]
Supplying, installing, testing and commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC. DSR I.No. 4.1.9.
Supplying and erecting GI pipe 20 mm dia B class 3.25 mm thickness with resin bonded flap rock wool /glass wool insulation, with necessary material as per specification No. ESD-HWP/TGP. DSR I.No. 4.2.2.
Supplying and erecting GI pipe 25 mm dia B class 4.05 mm thickness with resin bonded flap rock wool /glass wool insulation, with necessary material as per specification No. ESD-HWP/TGP. DSR I.No. 4.2.3.
Supplying and erecting 20/25 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.6 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC. DSR I.No. 4.2.18
Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity up to 20000 litres. DSR I.No. 4.8.7.
Supplying and erecting ISI mark GI pipe 25 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. DSR I.No. 16.5.3.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. DSR I.No. 6.1.19
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). DSR I.no. 16.3.7.
Supplying and erecting non return valve 25 mm dia in position made of gun metal complete. DSR I.No. 16.6.19
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.47 MB
BOQ_2204509.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .