| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC BOOTH NO 119 SECTOR 9 PANCHKULA 134109 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Lowest and reasonable Bid | |
| 2 | L2₹19.1 L+₹2.0 L (11.4%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC Other Than Lowest Bidder | |
| 3 | L3₹19.6 L+₹2.4 L (14.2%)Rejected-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-AOC Other Than Lowest Bidder | |
| 4 | L4₹22.2 L+₹5.0 L (29.3%)Rejected-AOC | L4 | Rejected-AOC Other Than Lowest Bidder | |
| 5 | L5₹24.6 L+₹7.4 L (43.2%)Rejected-AOC 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L5 | Rejected-AOC Other Than Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, Shimla Hills Jutogh
CWE, Shimla Hills Jutogh, Jutogh Cantt., Shimla-171008
REPAIR/MAINT OF HT NETWORK ( UG CABLES/ OH LINES) AND CONNECTED WORKS AT MIL STN KASAULI UNDER GE KASAULI
2022_MES_546660_1
CA NO. CWE/KAS-19 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kasauli
Plesae refer as per tender documents
6 documents required · 6 mandatory
₹500
GE Kasauli
₹50,000
Yes
27 Sept 2022
22 Aug 2022
22 Sept 2022
22 Aug 2022
20 Sept 2022
6 Sept 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation of poles/laying of under ground cables etc and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft disintegrated rock (considered for road cutting) complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Graded coarse aggregate of nominal size 40mm, indoor/outdoor substation/ 2 pole/4 pole structure boundary complete all as specified and directed.
M&L for Double wall corrugated HDPE duct pipe 120mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and directed.
Taking out old under ground HT XLPE/PVC cable of any size for found out fault from trenches/wall/roof/road/pipe/pole including taking out of brick layer and segregation/stacking of serviceable brick from trenches for reuse and broken brick bats removing from site complete all as specified and directed. Note:-Excavation, earth work shall be measured and paid for separately under appropriate item.
Re-Laying only old serviceable cable (cable obtained from item taking out old cable here-in-before after checking the fault) under ground HT XLPE/PVC cable 11000 Volt grade of any size in trenches/fixed to wall/pole/roof laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, overall PVC sheathed electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (Earthed) cross sectional area 95 Sqmm 3 core fixed to pole or in trenches or passing through pipe complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling / taking down unserviceable one complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling / taking down unserviceable one complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm including dismantling / taking down unserviceable one complete all as specified and directed.
S&F for GI tubing 100mm bore medium grade for cable protection under road crossing including dismantling / taking down unserviceable one complete all as specified and directed.
Un-binding from insulators and re–stretching only existing ACSR of any size on HT poles including binding the ACSR with new insulators with aluminium binding wire 2mm dia complete all as specified and directed.
All as per srl item No. 14 here-in-before but re–stretching only existing GI earth wire 4mm dia on HT poles & including binding with 1.63mm dia GI binding wire complete all as specified and directed. Note for item No. 14 to 15 :- For measurement purpose only length of each wire shall be measured.
Dismantiling and taking down old unserviceable ACSR conductor any size complete all as specified and directed.
M&L for ACSR conductor including jointing with existing conductor and stringing on pole and proper fastening to insulators with aluminium binding wires and required jumpering connection including dismantling/ taking down unserviceable one complete all as specified and directed.
M&L for Cross arms including replacement of bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling/ taking down unserviceable one complete all as specified and directed.
M&L for Disc type insulator porcelain, vitreous 145mm high and 255mm dia ball and socket type white, brown or green, double disc with tension clamp for conductor for working pressure voltage 11000 V including dismantling/ taking out unserviceable one from Pole complete all as specified and directed.
M&L for Pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150mm dia and 150 mm height for 11000 volts grade including dismantling/ taking out unserviceable one from Pole complete all as specified and directed.
M&L for Loop type insulator, porcelain vitreous white, brown or green of size 90x140mm and clearence hole 25.5mm including dismantling/ taking out unserviceable one complete all as specified and directed.
M&L for Lightning arrestor, Gapless Metal Oxide type, distribution class, System voltage-11KV, min rating-10KV, Discharge cap-10 KA, Line discharge class-1 complete with bracket and connection complete all as specified and directed.
M&L for Switch Air brake, gang operated, triple pole, mechanically operated mounted on HT insulators (12 insulators pin type ) and MS galvanised steel frame with operating mechanism operated from ground level with fixed contacts of phosphorous bronze and moving contacts of copper including operating rod for current rating upto 200 Amps, 11000 volts complete with locking arrangement, including 3 Nos drop out explusion type of fuses with fuse barrels of required capacity to suit load at site, also including provision of two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.
M&L for Expulsion type drop out fuse, single pole, 11000 V, 25 Amps complete with insulator 150mm dia and 150 mm height including dismantling /taking down old unserviceable one complete all as specified and directed.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI wire protection pipe 40mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unserviceable earthing complete all as specified and testing on completion complete all as specified and directed. Note - The units rate includes the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (light grade) for watering 40mm GI protection pipe (medium grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
M&L for Painting of HT steel tubular pole including cross arm/ bracing/clamps complete with one coat of aluminum paint including cross arm, bracings, supports, nuts, bolts, and including making alternative black and white strips on pole with synthetic enamel paint (each strip 30cm height) up to 1.5m height from top of PCC foundation block and writing pole Nos and including applying one coat of cement base paint on exposed surface of PCC coping and foundation block complete all as specified and directed.
M&L for trimming off branches of trees touching HT electric over head line by climbing up tree or using ladder at a height not less than 9.5 mtr from GL and making clear about 3 mtr in radius and carrying and depositing where directed not exceeding 50 mtr complete all as specified and directed.
Setting of 3 ph overcurrent + earth fault relays by secondary injection of current with suitable equipment for overcurrent & earth fault with high set and low set including necessary checking of trip circuit, relay circuit, closing circuit, alarm circuit, DC supply circuit, AC supply circuit and repair of same as required for 11 KV VCB after disconection of incoming and out going HT XLPE cable connection and reconnection of cable ends at existing terminals after completion of relay setting complete all as specified and directed.
Replacement of LED panel indicator complete with lamp Red/Yellow/green/amber complete all as specified and directed.
Replacement of LED panel indicator complete with lamp Blue/white complete all as specified and directed.
Replacement of spring charging motor, AC 230 volts complete all as specified and directed.
Replacement of battery 2 Volt 80 Ah maintenance free suitable for battery charger complete all as specified and directed.
Replacement of voltmeter analog type of size 96x96 mm complete all as specified and directed.
Filtration/dehydration of transformer oil of transformer voltage grade 11/0.433 KV,indoor/outdoor type, pole / plinth mounted installed at various electric sub station/ pump in situ till it achieves dielectric strength min 50 KV at 4mm gap complete all as specified and directed.
Topping up/ replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 50 KV at 4mm gap complete all as specified and directed. Note for serial item No 37 & 38:- (a) New transformer oil to be bought in company sealed ISI marked container with test certificate (b) Filtration /dehydration of transformer oil shall be carried out at the location where transformer is installed and necessary filter/dehydration plant having pressure gauge, hour meter, temperature gauge to be brought at site by contractor including electric supply arrangement to run the dehydration equipment and rate deemed to be included in the quoted rate.
Replacement of silica gel grains in the breather assembly of transformer complete all as specified and directed.
Replacement of breather assembly made with polycarbonate base and clear acrylic glass of size min 50mm dia, min 120mm long of suitable size as per site requirement for transformer complete all as specified and directed.
Replacement of transformer temperature gauge dial type having temp range 0 to minimum 120 degree celcius complete all as specified and directed.
Opening of top cover in situ or at wksp for transformer capacity upto 63 KVA to 250 KVA, 11/0.433 KV volts grade by unscrewing all nuts, bolts & washers, draining out transformer oil upto required level and keeping in clean container for replacement of HT/LT bushings, for lifting of core assembly, for cleaning/repair and refixing complete with new cork sheet gasket, existing/new nuts, bolts & washers for transformer indoor/outdoor type, refilling of oil complete all as specified and directed. Note:- HT/LT bushings, Studs, Nuts, bolts & washers required new are mesured here-in-after as separate item.
Replacement of transformer porcelain bushing outdoor/indoor type in situ/wksp suitable for 11 KV grade complete with brass stud, rubber bush, washers, nuts, checknuts and cork sheet gasket for the rating of 63 KVA to 250 KVA, 11/0.415 KV transformer complete all as specified and directed. Note: Opening of top cover measured separately.
Replacement of transformer LT porcelain bushing indoor/outdoor type in situ/wksp suitable for 1100 volts grade complete with rubber bush, washers, nuts, checknuts and cork sheet gasket for the rating of 63-100 KVA, 11/0.433 KV transformer complete all as specified and directed. Note:-(a)Opening of top cover measured separately. (b) Brass stud measured separately.
All as per item No-44 here-in-before but for transformer capacity 100-200 KVA, complete all as specified and directed.
All as per item No-44 here-in-before but for transformer capacity 200-300 KVA, complete all as specified and directed.
Replacement of brass stud suitable for LT 1100 volts grade with cork & rubber washer, double Brass nuts & brass washer at both end of stud for Transformer capacity 63-100 KVA, complete all as specified and directed.
All as per item No-47 here-in-before but for transformer capacity 100-200 KVA, complete all as specified and directed.
All as per item No-47 here-in-before but for transformer capacity 200-300 KVA, complete all as specified and directed.
Taking out manually defective transformer of capacity upto 250KVA from its position upto road n. exc 1KM and transportation by vehicle to workshop n. exc 30KM and reinstallation at original position after repair or Shifting of transformer from present location to original location complete all as specified and directed. Note:-Rate deemed to included for necessary HT/LT cable/ACSR, earthing connection after installation.
Lifting up carefully transformer core after dismantling carefully terminal connections from core to HT/LT bushings, tap changer assembly, drainout all oil and keeping in clean container, dismantling all HT & LT coils from core for rewinding, and reassembling complete with HT/LT coils to core, required necessary numax paper insulation, insulating press board, precompressed board size of 6mm/3mm/1.5mm/1mm, varnishing, heating to achieve insulation level not less than 1000 megaohms at both HT & LT side, core at transformer chamber, tap changer assembly, terminal connection, top cover with new cork sheet gasket, required existing/new nuts, bolts & washers, filling transformer oil, testing after repair for the 250 KVA, 11/0.415 KV transformer. complete all as specified and directed. Note:- Opening of top cover, Rewinding of HT/LT coils, transformer oil, nuts, bolts & washers, HT/LT bushings, required new are measured separately under appropriate item.
Rewinding of HT coils suitable for 11000 volts grade with new DPC/super enamelled copper wire having Class-F insulation as per existing size and turns for capacity of transformer 75-850 KVA complete all as specified and directed.
Rewinding of LT coils suitable for 1100 volts grade with new DPC /super enamelled copper strip having Class-F insulation as per existing size and turns for capacity of transformer 75-850 KVA complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal head at one end and screwed the other with washer and one hexagonal nut n. exc 5cm long and 5 to 10mm dia of neck complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .