Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.7 L+₹5,363 (0.34%)Rejected-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L2 | Rejected-AOC 2nd Lowest Bidder | |
| 3 | L3₹16.9 L+₹1.3 L (8.15%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | Rejected-Technical 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | - | Rejected-Technical OID Not Found |
Tender Value
Refer Docs
EMD Value
₹30,700
Closing Date
17 Oct 2022, 11:00 amClosed
EE-I, West Kol Elect. Divn., PWDi
New Secretariat Building, Block-C, 4th floor, 1, K.S Roy Road, Kolkata-700001
Arrangement of Air-conditioning system at 5th floor of Block-B of New Secretariat building in respect of accommodation of different offices of Honble High Court, Calcutta
2022_WBPWD_412885_1
WBPWD/EE-WKED/ NIQ-46/ 2022-23(2nd Call)
Open Tender
A/C ORG
Item Rate
15 days
Block-B of New Secretariat Building
Please refer Tender documents.
5 documents required · 5 mandatory
₹30,700
17 Jan 2023
30 Sept 2022
19 Oct 2022
30 Sept 2022
17 Oct 2022
1 Oct 2022
Amount
Supply & delivery of 240V split Air-conditioner machine having cooling capacity not less than 10000W, ISSER 3.37 to 4.1, Noise level not more than 53db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A. (Make-O-General model no-ASGA36FUTC-B or equivalent model of Mitsubishi Electric/Mitshubishi Heavy Industries as per approved by EIC/authority).
Supply & delivery of 240V split Air-conditioner machine having cooling capacity not less than 6875 W, ISSER 3.8 to 4.39, BEE rating not less than 3 star, Noise level not more than 46db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A. (O-General Model no-ASGA24BMWA-B or equivalent model of Mitsubishi Electric/Mitshubishi Heavy Industries as per approved by EIC/authority).
Supply & delivery of 240V split Air-conditioner machine having cooling capacity not less than 5200W, ISSER 3.59 to 4.1, BEE rating not less than 3 star, Noise level not more than 39db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A. (O-General Model no.-ASGA18FTTC-B or equivalent model of Mitsubishi Electric/Mitshubishi Heavy Industries as per approved by EIC/authority).
Supply & delivery of 240V split Air-conditioner machine having cooling capacity not less than 3600W, ISSER 3.6 to 4.0, BEE rating not less than 3 star, Noise level not more than 33db(Lo). This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A.. (O-General Model no-ASGA12BMWA-B or equivalent model of Mitsubishi Electric/Mitshubishi Heavy Industries as per approved by EIC/authority).
Supply & delivery of 240V split Air-conditioner machine having cooling capacity not less than 2650, ISSER 3.53,CMM 13.4, BEE rating not less than 3 star, Noise level not more than 31db(Lo). This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A. (Mitsubishi Electric-MS-GS10VF or equivalent model of Mitsubishi Heavy Industries/O--General as per approved by EIC/authority).
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 3/8"(for discharge) 1.15mm thickness copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.
Supply & Installation of Extra Add-on items- HVAC grade 1/2"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.
Supply & Installation of Extra Add-on items- HVAC grade 3/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.
Installation, testing & commissioning of the above-said split AC outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of E.I.C.
Supply & Laying of 4core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/Polycab as approved by E.I.C)
Supply & Laying of 4core 4sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Gloster/Havells/Finolex/Polycab as approved by E.I.C)
Supply & Laying 3/4"(20mm) hard PVC pipe (heavy type)for water drainage.
Supply and laying 1''(25mm) heavy type PVC pipe for water drainage.
Supply and fixing of 19mm thickness plywood of size- (4ft x 2ft =8sqft) on exsisting window after cutting glass by diamond cutting tools for passing refrigerent and drain line as per direction of E.I.C.
Supplying, fabrication & fixing 1Nos. M.S angle of 6 mm thick of size ( 40 mm x 40 mm) of 1m length for making platform for installation of outdoor unit of the afore-said split AC incl. drilling 4 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete cement concrete (1:1 ½ :3) etc. fabricated with 2Nos. horizontal angle of 25 mm x 25 mm x 5 mm of 3m. length and area :-3Mtr X 1 Mtr incl. S&F of safety cage made of angle (25X25X5mm) and flat (25X5mm) iron with necessary painting
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
NATIONAL AIRCON
UNIVERSAL SALES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .