Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.9 LAccepted-AOC GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹16.7 L+₹1.4 L (9.26%)Rejected-AOC 0 0 0 NEAR DAK BUNGLOW NH 1 A NH 1A UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 2 | Rejected-AOC L2 | |
| 3 | 3₹16.9 L+₹1.6 L (10.3%)Rejected-AOC | 3 | Rejected-AOC L3 | |
| 4 | 4₹17.0 L+₹1.6 L (10.6%)Rejected-AOC | 4 | Rejected-AOC L4 | |
| 5 | 5₹17.0 L+₹1.7 L (11.2%)Rejected-AOC NOT FOUND | 5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
19 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) SIRSA
GE(AF) SIRSA 125055
As per BOQ/Price Schdule
2020_MES_389189_1
GE/SRA/T-13 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
333 days
GE(AF) SIRSA
As per NIT/Tender documents
3 documents required · 3 mandatory
₹500
GE(AF) SIRSA
₹40,000
15 Mar 2021
23 Oct 2020
21 Nov 2020
23 Oct 2020
19 Nov 2020
7 Nov 2020
23 Oct 2020 - 5 Nov 2020
60 days
Amount
S&F Heat Shrinkable LT 1100 Volt Straight Through Joint suitable for Aluminium Conductor Cable, cross sectional area 25 Sqmm to 50 Sqmm, 3½ Core, complete all as specified and directed.
S&F PVC insulated Multi Stranded FRLSH Copper Conductor Cable 1.5 Sqmm unsheated, Single Core for connection of Street Light Fitting including taking down unserviceable Cable of any description, complete all as specified and as directed.
S&F PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street Light Fitting including taking down unserviceable Cable of any description, complete all as specified and as directed.
S&F PVC Insulated Multi Stranded Flat Service Aluminium Conductor Cable, 1100 Volt grade, heavy duty, served with inner sheathing of PVC Tape and overall PVC sheathed of size 16 Sqmm 2 Core including taking down unserviceable Cable of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 20 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 30 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 45 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 50 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 60 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 80 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 90 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 120 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 180 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed. NOTE : FOR ITEM No. 5 TO 13 MAKE of Electronic Driver shall be provided as per Light Fittings make available at Site (Havells/Bajaj/Surya).
S&F PCB Card suitable for Multi LED Light Fitting of capacity 20 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 30 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 45 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed. NOTE : FOR ITEM No. 14 TO 16 MAKE of PCB Card shall be provided as per Light Fittings make available at Site (Havells/Bajaj/Surya).
S&F Surge Protection Device of capacity 10 KV Single Phase 50 Hz including taking down unserviceable Driver of any description, complete all as specified and as directed. NOTE : MAKE of Electronic Driver shall be provided as per Light Fittings make available at Site (Havells/Bajaj/Surya).
M&L for replacement of Pole Mounted Junction Box 225x295x122mm, having insulated and made out of polycarbonate with Fiber reinforced rated for degree of Ingress Protection IP 66/65, having Gasket Material shall be Polyurethane and the Gasket shall be internally embedded, Tested at Glow wire Test for 960 Degree Celsius with plastic Mounting Bracket, din rail, Mild Steel Flat Iron clamp, Nuts , Bolts and Washers, complete all as specified and as directed.
S&F Connector suitable for fixing of Cable of size Cross sectional area 25 Sqmm to 50 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and as directed. NOTE : MAKE of Connector shall be provided as per Light Fittings make available at Site (Havells/Bajaj/Surya).
S&F Multi LED Street Light Fitting of capacity 30 Watt IP 66, having Die-cast Aluminium Housing, Weather Proof with Accessories including taking down unserviceable Street Light Fittings from the Electric Pole, complete all as specified and as directed.
S&F Multi LED Street Light Fitting of capacity 45 Watt IP 66, having Die-cast Aluminium Housing, Weather Proof with Accessories including taking down unserviceable Street Light Fittings from the Electric Pole, complete all as specified and as directed.
S&F Multi LED Flood Light Fitting of capacity 50 Watt with all Fittings including taking down unserviceable Light Fitting of any description, complete all as specified and as directed.
S&F Multi LED Flood Light Fitting of capacity 80 Watt with all Fittings including taking down unserviceable Light Fitting of any description, complete all as specified and as directed.
S&F Multi LED Street Light Fitting of capacity 120 Watt IP 66, having Die-cast Aluminium Housing, Weather Proof with Accessories including taking down unserviceable Street Light Fittings from the Electric Pole, complete all as specified and as directed.
M&L for replacement of Thermoplastics, Polyamide Glands with Lock Nuts Made of Poly amide of size M32 as per site requirement, complete all as specified and as directed.
S&F Multi LED Aviation light 6 Watt -500mm with IP-65 Protection 220 Volt 50 Hz, including taking down unserviceable Light Fitting of any description, complete all as specified and as directed.
S&F Multi LED Bollard 8 Watt -500mm with IP-65 Protection 220 Volt 50 Hz, including taking down unserviceable Light Fitting of any description, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) as in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling PCC Copping and/or removing damaged PCC Copping, complete all as specified and as directed.
M&L GI Pipe Bracket made out of Galvanised Iron Tubing 32mm bore (dia), light grade, 1.50 METRE long bent to shape as per specified for fixing Street Light Fitting including taking down unserviceable GI Pipe Bracket, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade having 70 Cm to 100 Cm with long Bends, Each for Incoming and Outgoing Cables, grouting in Cement Concrete including taking down unserviceable GI Tubing of any description, complete all as specified and as directed. NOTE : Cement Concrete will be measured and paid for separately under appropriate Item.
S&F Rigid Steel Conduit 25mm dia exclusive of Boxes (Junction/ Terminal) but inclusive of all Tee, Bends, Elbows, Reducers, Bell mouth, etc. fixing Accessories suchs as Couplers, Lock Nuts, Saddles, Pipe Hook, etc. including taking down unserviceable Conduit of any description, complete all as specified and as directed.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable Pipes, Bricks, etc. and depositing to MES store yard for reuse complete all as specified and as directed. NOTE : Necessary Earth Work will be Measured and Paid under appropriate Items.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
Making Hole under Road/ Hardstanding including cutting, etc. with manual anger or bookie not exc. 100mm dia, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 10 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 16 Sqmm 2 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 25 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 35 Sqmm 3.5 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 50 Sqmm 3.5 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No. 33 here-in-before) 1100 Volt grade, cross sectional area 10 Sqmm to 25 Sqmm 2/3½/4 Core after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No. 33 here-in-before) 1100 Volt grade, cross sectional area 35 Sqmm to 50 Sqmm, 3½/4 Core after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed.
Laying in Trenches Bricks (Serviceable Bricks obtained from Item No. 32 here-in-before), for Cable Protection, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 200 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for Bollard Light Fitting of capacity 8 Watt including taking down unserviceable Driver of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 50 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 60 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 80 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 90 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 120 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Multi LED Light Fitting of capacity 180 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed.
S&F PCB Card suitable for Bollard Light Fitting of capacity 8 Watt including taking down unserviceable PCB Card of any description, complete all as specified and as directed. NOTE : FOR ITEM No. 49 TO 57 MAKE of PCB Card/Electronic Driver should be provided as per Light Fittings MAKE available at Site (Havells/Bajaj/Surya).
M&L Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. NOTE : FOR ITEM NO. 1 TO 58 (a) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate. (b) Contractor or his Authorised Representitive has to inspect all Street/ Security Lights on Daily basis at this own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day, failing which Rs. 20.00 PER DAY will be recovered from the Contractor. (c) Contractor has to ensure serviceability at there own Vehicle/arrangement of all Street/ Security Lights of TECHNICAL, DOMESTIC & ZHOPRA AREA on Daily basis in any Weather Condition. (d) Contractor has to arrange own movable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defects rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account. In the case of Day Time Street/ Security Lights be 'ON' by the Contractor, necessary recovery will be made as per CA Provision as recorded by Automation System. (e) Attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments for remove the breakdown. Fault will be intimated through Telephone/ SMS and in case Contractor failed, recovery as per CA Provision will be made. (f) Repair Party will be reported every Morning and Evening to JE E/M. (g) Recovery Rate for non adhering of Instructions as Panalties will be made as per CA Provision. (h) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department.
SHIVAM ENTERPRISES
YOGINDER KUMAR GUPTA AND COMPANY
Aditi Formation Company
shiv shanker enterprises
BS BUILDERS
YESH BUILDERS
AMBIKA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .