Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹53.8 L+₹1.3 L (2.39%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹55.9 L+₹3.3 L (6.26%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹56.5 L+₹3.9 L (7.37%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹57.1 L+₹4.5 L (8.65%)Rejected-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
18 Oct 2022, 6:00 pmClosed
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR AND MAINT OF HT DISTRIBUTION SYSTEM INCL DISTRIBUTION TRANSFORMER 11 KV AND REPAIR AND MAINT OF UNSV EQPT EARTHING INSTALLATION EARTHING AT SECTOR C AND D AND ADJASCENT AREA UNDER AGE E/M- I OF GE 865 EWS AT LEH.
2022_MES_551364_1
138WE/L-52/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.1 L
Yes
26 Nov 2022
13 Sept 2022
25 Oct 2022
13 Sept 2022
18 Oct 2022
4 Oct 2022
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and exc 1.5m and not exc 3.0 m in depth and getting it out for pole erection in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for crushed stone / sand cushioning to UG cable, provide with the layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed by Engr-in-Charge. (Note : Pured thickness only to be measured for payment as per SSR)
Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x180mm x 40mm placed perpendicular to the cable complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm dia complete all as specified and directed by Engr-in-Charge.
Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC /GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.
Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 95 sq mm complete all as specified and directed by Engr-in-Charge.
S&F in repairs cable end joint boxes 95 Sqmm, 3 core XLPE 11kV HT Cable cold shrinkable outdoor type, complete all as specified and directed by Engr-in-Charge.
S&F in repairs cable straight through joint 95 Sqmm, 3 core XLPE 11KV HT Cable cold shrinkable outdoor type complete incl necessary excavation and earth work complete all as specified and directed by Engr-in-Charge.
S&F in replacement unserviceable neon indicating lamps from cubical panel complete all as specified and directed by Engr-in-Charge.
M&L for replacement of voltmeter 0 to 500 Volts complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Transformer Oil, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Ammeter 0 to 600 Amps 135mmx135mm, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Ammeter 0 to 1000 Amps 135mmx135mm, complete all as specified and directed by Engr-in-Charge.
M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level complete all as specified and directed by Engr-in-Charge. Note: (a) Oil topping up shall be measured and paid separately. (b) Filtration shall be done at site and on line. (c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge. (d) Dielectric strength of the oil shall not be less than 50 kV after filtration & the rate quoted for the items shall be deemed to include the filtration till the desired dielectric strength is achieved complete all as specified and directed by Engineer in Charge
Supply and fixing of gang operated air break switches HT 11KV grade outdoor type, triple pole of capacity 200 amps rating mounted on polymer based 09 insulators fitted on steel frame horizontally, mechanically operated mechanism from ground level including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements complete all as specified and directed by Engr-in-Charge..
Supply and fix in replacement of drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on polymer based insulators for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 25-50Amps and connected with suitable size of ACSR conductor as jumper between GOD and DO fuse, with 11 KV HT PVC sleeve, with all fittings/accessories etc, including taking down of only 3 fuses complete all as specified and as directed by Engr-in-charge.
Supply, fixing and connecting HT 11 KV outdoor expulsion type lightning arrestors with mounting accessories complete fixed on cross arms of 2 pole structur and connected with same size of ACSR conductor as O/H HT conductor with 11 KV KT empire tape insulation with all fittings, transmission class, having discharged capacity of 65 kilo amps and suitable for working pressure of HT 11 KV complete all as specified and directed by Engr-in-Charge
S&F in repair disc insulator porcelain vitreous brown 145mm high and 255mm dia ball and socket type single disc assembly for tension with tension clampstor conductors working pressure 11000 volts complete all as specified and directed by Engr-in-Charge.
S&F in repair pin/post type polymer based insulator 150mm height and 150mm dia suitable for 11 KV grade insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut,complete all as specified and directed by Engr-in-charge.
M&L for stay assembly complete with 30x30x6mm thick plate and 20mm dia stay rod and stay insulators all as shown in electrical plate No. 1 including necessary excavation, earthwork stay bow, stay wire and PCC complete all as specified and directed by Engr-in-Charge.
S&F for aluminium tubing heavy duty of size 32mm outer dia, 20mm inner dia, 06 mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators connection with jumpers including removal of unserviceable one complete all as specified and directed
S&F for aluminium strip of size 32mm x 10mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators with jumpers including removal of unserviceable one complete all as specified and directed
Supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug bolts, nuts and screws as specified type 410 SP-55(11.0 meters long) complete all as specified and directed by Engr-in-Charge
M&L for cement concrete(1:4:8) type D2 in foundation filing and mass concrete using 40 mm graded stone aggregate for pole/stay foundation etc complete all as specified and directed by Engr-in-Charge
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40 mm graded stone agg for pole/stay foundation etc complete all as specified and directed by Engr-in-Charge
Materials and labour for cross arms, bracings supports clamps and back plates fabricated from structural steel section including nuts bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of two quotes of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge.
M&L in replacement for aluminium conductor, steel re-inforced complete all as specified and directed by Engr-in-Charge.
M&L in replacement for Galvanised steel wire 3.15 or 4.00 dia complete all as specified and directed as Engr-in-Charge.
M&L earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, checknuts and washers etc made of GI and connected earthing test points all as shown in electrical plate no. 5 of SSR Part-1 of 2009.00 and as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm) funnel with grade and lugs, including galvanised iron strip 32 X 6 m with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified and directed by Engr-in-Charge
M&L for HT jumper with the help of Aluminium Conductor Steel Re-inforcement covered with insulating material/sleeve and including lugs at both ends at suitable at site. The length of jumper shall not be less that 2.5 meter including connection with the help of connector on the HT pole complete all as specified and directed by Engr-in-charge.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-charge.
Material and labour for painting to existing HT pole 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
Material and labour for painting to existing HT 2 pole structure 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
Material and labour for painting to existing HT 4 pole structure 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
Taking down old bus bar chamber, M&L for fabricating, supplying, installing, testing & commisioning of out door type CPRI approved factory made HT 11kV feeder pillar box of size not less than 165cm x 80cm x 117 cm with top cover 5 cm projected allround made with 3 mm thick CRCA sheet, weather proof, vermin proof with double door, handle with locking arrangement, powder coated with 7 tank process including PVC insulated copper bus bar 3 nos size of 130cm x 5 cm x 0.5cm & mounted on HT 11 kV insulators 9 nos (three nos per bus bar) insulators should be mounted on MS sheet with thickness 3mm made in shape including weather proof painting. The feeder pillar box should be mounted on ms frame made up with MS angle of size 60mm x60x 6 mm duly covered with MS sheet 3 mm thick on all sides about 35cm from the bottom of the FPB & all side removeable type including two coats of syntheic enamel paint over one coat of red oxide primer including necessry excavation earth work in any type of soil, pcc block (1:3:6) of size 120cmx25cmx60cm- 2nos embedded in ground etc complete including writing name of feeders on FPB with size of leetters not less than 10 cm, complete all as specified and directed by Engr-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire, complete all as specified and directed by Engr-in-Charge.
Supply only Chain link MS galvanised fencing, any size or type, complete all as specified and directed by Engr-in-Charge. (Note : The necessary earthwork and PCC will be measured and paid seperately under relevant item.)
Supply and fixing in replacement Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including, cutting tops to shape as directed drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling bolting or reveting etc and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engr-in-Charge. (Note : The necessary earthwork and PCC will be measured and paid seperately under relevant item)
Supply and fixing in replacement Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC LT/HT line phase seperator suitable for 2/3 wire having phase to phase gap (Spacing between the conductrs) 300mm or 380mm as per requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC LT/HT line phase seperator suitable for 4/5 wire having phase to phase gap (Spacing between the conductrs) 300mm or 380mm as per requirement complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement X-volt insulating mats 2.5 mm thick in roll size of 1Mtr x 10Mtr including suitable adhesive for fixing it on the floor/surface to be laid in electrical power house/sub stations, to suit IS 15652:2006 to provide earth insulation for 11 KV voltage system complete all as specified and directed by Engr-in-Charge.
Disconnecting and removing HT/LT Cables and other connections and Strip opening of transformer 250 to 630 KVA 11 KV/433 volts indoor/outdoor type of any make after unsecrewing nuts/bolts screws and connected accessories such as breather, conservator tank, temperature gauge for replacement of defective HT/LT coils,replacement of drain valve,paper insulation strip, breather etc and other defective parts (payment of defective replaced parts shall be measured and paid seperately. Re-assembling after replacing the defective coils parts and replacing the top gasket sheet and other insulating, packing materials and testing, complete all as specified and directed. Note :- The reassembling element covers the assembling of parts not to be changed where as for the rest it shall be the part of the item being replaced.
All as per Srl item No. 47 above but of capacity 100 to 250 KVA, complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 47 above but of capacity upto 100KVA, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of HT coils made out of super enameled HT copper winding wire of transformers capacity upto 630 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of HT coils made out of super enameled LT copper winding wire of transformers capacity upto 630 KVA, complete all as specified and directed by Engr-in-Charge. Note :- The coil to be replaced shall have same number of truns gauge insulation value matching with manufactures design.
Supply and replacement HT 11 KV bush suitable for indoor/ outdoor type upto 500 KVA transformers complete with brass stud, 04 Nos brass nuts, brass cup and packing gasket, complete all as specified and directed by Engr-in-Charge.
Supply and replacement brass stud for LT side suitable for transformers 250 to 500 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and replacement brass stud for LT side suitable for transformers upto 250 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and replacement temperature guage 0-1000 degree celsius range dial type, complete all as specified and directed by Engr-in-Charge.
Supply and replacement Insulator and Cupinsulator for bush of LT Side suitable for transformers upto 500 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and replacement Insulator and Cupinsulator for bush of HT Side suitable for transformers upto 500 KVA, complete all as specified and directed by Engr-in-Charge.
M & L for reapir to tapping switch including replacement of copper contact,bakelite plate and operating rod upto 500 KVA Transformer, complete all as specified and directed by Engr-in-Charge.
Dehydration and filteration of transformer oil to achieve dilectric strength of 40 KV at 4mm gap and refilling the same after achieving the desired dilectric strength, complete all as specified and directed by Engr-in-Charge.
Supply and fill up transformer oil as in topping up/ refilling of transformer having dielectric strength not less than 40 KV at 4mm gap conforming to ISI, complete all as specified and directed by Engr-in-Charge.
Removing the existing paint from the transformer of capacity 250 KVA to 500 KVA by scratching / rubbing , cleaning and preparation of surface. Repainting the transformer by applying one coat of synthetic enameled paint of approved quality of colour, complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 61 above but of capacity upto 250 KVA,complete all as specified and directed by Engr-in-Charge.
Supply and replace transformer breather complete with silca gel for capacity upto 250KVA transformer all as specified and as directed.
Supply and replace transformer breather complete with silca gel for capacity 250 to 500KVA transformer, complete all as specified and directed by Engr-in-Charge.
Reconditioning of LT coils of aluminium/ copper wound transformer by replacing the old paper tape insulation. Necessary packing / paper insulation, strengthening the entire LT strip coils as per manufacturers design complete all as specified and directed of transformer upto 630 KVA capacity, complete all as specified and directed by Engr-in-Charge.
All as per items ser no 65 but for 200-300 KVA transfarmer, complete all as specified and directed by Engr-in-Charge.
All as per items ser no 65 but for 50-160 KVA transfarmer, complete all as specified and directed by Engr-in-Charge.
Supply and fixing Silica Gel (having blue colour)to be filled in transformer breather, complete all as specified and directed by Engr-in-Charge.
M&L replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 400 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles, complete all as specified and directed by Engr-in-Charge.. (Earth work, cable protection and sand cushioning shall be measured and paid for separately)
Replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 120 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified. (Earth work, cable protection and sand cushioning shall be measured and paid for separately)
Replacement of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-I flate size 250 x 150x40mm , complete all as specified and directed by Engr-in-Charge.
Supply and fix Copper Thimbale of size 120/150/185/240/300/400 Sq mm, complete all as specified and directed by Engr-in-Charge.
Supply and fix Alluminium Thimbale of size 10/16/35/50/70/95 Sq mm, complete all as specified and directed by Engr-in-Charge.
Supply and fix Alluminium Thimbale of size 120/150/185/240/300/400 Sq mm, complete all as specified and directed by Engr-in-Charge.
Supply & replacement of tubes light grade of size 80 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, complete all as specified and directed by Engr-in-Charge.
Replacement of cable end termination kit heat shrinkable indoor type suitable for XLPE HT 11000 volts cable of size 95 Sqmm 3 core fixed in replacement, complete all as specified and directed by Engr-in-Charge.
Replacement of air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators 15 Nos & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 200 Amps, complete all as specified and directed by Engr-in-Charge.
Replacement of pin insulator porcelain white, brown or green 100 mm height, 65 mm dia for 1100 volts grade complete, complete all as specified and directed by Engr-in-Charge.
Restringing/ restretching aluminium conductor/ GI wire on LT/HT over head lines including necessary binding with binding wire with insulator , connections of incoming and out going cables, complete all as specified and directed by Engr-in-Charge.
Disconnecting and removing LT Cables and other connections and Strip opening of Servo stabilizers of up to 100 KVA 433 volts indoor/outdoor type of any make after unsecrewing nuts/bolts screws and connected accessories such as breather,temperature gauge for replacement of defective LT coils,replacement of drain valve,paper insulation strip,electronic cards of each phase(RYB) etc and other defective parts i.e. servo motor ,out /IN terminals. (payment of defective replaced parts shall be measured and paid seperately. Re-assembling after replacing the defective coils parts and replacing the top gasket sheet and other insulating, packing materials and testing complete all as specified and directed by Engr-in-Charge. Note :- The reassembling element covers the assembling of parts not to be changed where as for the rest it shall be the part of the item being replaced.
M & L for replacement of servo motor of existing model and capacity incl. testing and commissioning after repair, complete all as specified and directed by Engr-in-Charge.
M & L for replacement of servo electronic card of existing model and size incl. testing and commissioning after repair, complete all as specified and directed by Engr-in-Charge.
Material and labour for Checking/ Testing of resistance value of any type of earth pits by disconnecting earth continuity conductor from test terminal block/panel/ equipment at various location of building earthing/equipment earthings falling under AOR of GE 865 EWS and reconnecting the earth continuity conductor after testing. Earth tester will be provided by contractor. Earth tester must be calibrated. Contractor has to prepare record of test of earthings indicating the locations in surrounding of bldgs and give the earthing No., type of earthings i.e earthing for E/M Equipments (EQ1 , EQ2 etc), lightning protection earthing (LA1, LA2 etc) & Bldg earthing (BA1, BA2 etc).Earth test results shall be recorded in reference to Earth Nos provided for the instln. Earth test to be signed by Rep of contractor, Rep of MES and Rep of user. Test reports to be submitted in duplicate, complete all as specified and directed by Engr-in-Charge.
Material and labour for supply, installation, testing and commissioning of chemical earthing Pure copper electrode 76mm x 6 mtr long. grade, Copper strip 32x6 mm (Strip in pipe type electrode) and pure copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the GI pipe electrode. Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed.Vendors are bound to get earthing result less than or upto 2 Ohm with or without grid of earthings(Maximum number of new earthings in grid are restricted to 3 nos) copper strip required for interconnection of earth pits in grid must be laid 2 ft below the ground level and the same must be treated with chemical (BFC) if required to achieve resistance value. Any additional work and material required to achieve the required result is included in the cost. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore. Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out quarterly by MES authority. copper strip must be connected with copper pipe electrode and other joints through nut bolt in addition to welding, complete all as specified and directed by Engr-in-Charge. Note:- (i) Earth strip from top connector of electrode to test point and further connection to LT panel/AF equipments/ for grid of earthing shall be measured and paid separately. (ii) Maximum no. of New earthings to be connected in grid are restricted to 03 Nos.
M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, checknuts & washers of copper and connecting to test point , providing charcoal and common salt ,all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm , 7.5 meter long, etc complete all as specified and directed. Note- (i) Vendors are bound to get earthing result less than or upto1 Ohm with or without the grid of earthing.(Maximum number of new earthings in grid are restricted to 3 nos) Any additional work and material required to achieve the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate)
S&F in replacement of test point made out of gun metal or phosphorous bronze of size 75x50x25mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal blockmade out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
M&L for fixing earth indicators made out of 3 mm thick MS sheet of size 200 mm x 300 mm duly fixed in MS angle iron 25 mm x 25mm x 3mm of 600 mm long fixed to ground by means and including necessary cement concrete foundation and painting with one coat of synthetic enamel paint over a coat of red oxide primer complete for writing earth reading and connected plant/ panel etc. and excavation and earth work, complete all as specified and directed by Engr-in-Charge.
Taking down carefully from roof / wall of the building loose / hanging / deshaped / GI strip/ aluminium strip / copper strips of any size & type including unserviceable insulators etc, complete all as specified and directed by Engr-in-Charge.
S & F GI earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required, complete all as specified and directed by Engr-in-Charge.
Supply & fix aluminium strips 25x3 mm on porceline insulator 'T' type not more than 50 cm apart, complete all as specified and directed by Engr-in-Charge. Note: M&L Porcelain insulators with nuts bolts and screws will measured and paid separately
Supply and fix air termination single pointed aluminium 12 mm dia & 300 mm long including nuts & bolts for fixing air termination rod to pole/ pipe duly insulated by providing appropriate insulator all as required at site. complete all as specified and directed by Engr-in-Charge.
M&L for earthing chamber of size 450x450x300 mm depth outside & 250x250x300 mm depth of PCC (1:3:6) type C1 complete all as specified and directed by Engr-in-Charge.
S&F in repair of earthing pit cover 50 mm thick precast slab of RCC 1:2:4 type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm incl 6 mm dia bar handle, complete all as specified and directed by Engr-in-Charge.
M&L for excavation and earthwork for reconditioning of existing earth with border line result lying between 6 Ohms to 15 Ohms for further improvement of resistance value and re-testing the test value of the treated earth and re construction of PCC pit cover wth Cast Iron frame work, pit cover complete all as specified and directed by Engr-in-Charge. Note : The quantity of charcoal, salt and magnesium sulphate required for reconditioning of earth will be measured and paid seperately under relevant item.
Supply and fixing of common salt for earthing complete, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of of magnesium sulphate for earthing complete, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of Charcoal for earthing, complete all as specified and directed by Engr-in-Charge.
M.S Sharma Enterprises
SUMEET TRADING CORPORATION
EESSI
M/S NANCY ENTERPRISES
Horizon Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .