Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
Closing Date
23 Oct 2026, 4:00 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer
O/o E. E., D. W. and S. Mech. Div. Dumka
Rajmahal Mega rural water supply scheme
2026_DWSD_119827_1
E-quotation No. 04 2026-27
Open Tender
Machineries/ Mechanical Engg Items
Empanelment
Dumka
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
15 Oct 2026
15 Oct 2026
24 Oct 2026
15 Oct 2026
23 Oct 2026
15 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Intake floating jetty at Ganga river (Rajmahal) | |||||
| 1.01 | Supplying, Installation, testing and commissioning of electrically driven Horizontal split casing Centrifugal pump set make (Kirloskar/WPIL/Mather & Platt /Jyoti) having discharge capacity of clear water 270m3/h against total head of 35.44 meter coupled with TEFC sq. cage induction motor make (Kirloskar/ Crompton/Jyoti) operated on 415 + 10% volts, 50HZ, 1400-1500 RPM mounted on common M.S. fabricated base plate with CIDF sluice valve-1 no, CIDF NR valve-1 no, pressure gauge-1 no, tire coupling-1 no, etc. and doing fabrication work for connecting the exiting common header delivery line. all complete. | 1 | Set | - | - |
| 1.02 | Cost towards opening, dismantling, cleaning and repairing and overhauling of 60 HP HSC C/F pump set having 1475 rpm head 35.44 mtrs. discharge 270 m3 /hr make- WPIL with following works:-
( i) Complete dismantling of Pump set from base plate and opening & cleaning of Pump with all labour, tools and tackles .
(ii) Repairing Re-metalling of stainless steel pump shaft, turning & finishing as per sample at lathe and fitting -01 No.
(iii) S.S. Shaft sleeves both sides- 02 Nos. as per sample.
(iv) Making neck-ring as per sample- 02 Nos.
(v) Cheek Nut- 01 No.
(vi) S/F coupling rubber -01 No.
(vii) Making of gland titener as per sample.-02 Nos.
(viii) Repairing of bearing housing -02 Nos.
(ix) Double Ball bearing -01 No.
(x) Ball bearing -02 No.
(xi) Paper Packing, Nut-bolts as required.
(xii) Repairing of damaged CI impeller of pump -01 No with CI welding, turning & finishing as per sample-01 No.
Complete re-assembling and overhauling of Pump, installing at site with all labour, tools & tackles and Testing on full load with transportation charge up & down etc. including the deduction of scrap materials all complete. | 1 | set | - | - |
| 1.03 | Cost towards supplying all labour tools and tackles for complete opening, dismantling, of 60 HP, 415±10 Volt, 50c/s, star delta 3 phase induction motor (make- Marathon Motors Ltd.) by supplying supper enameled copper wire and then tapping, varnishing, heating & testing on full load and repairing of stator and rotor with including the deduction of cost of burnt copper wires etc. all complete .Weight of copper wire approx. 30 kg.
With changing of following bearing:- DE/NDE-6313/6313 as per sample- 2 Nos and transportation charges of above pump motor set and other fittings materials from p/plant to workshop and vice versa etc at raw water p/plant. | 1 | Set | - | - |
| 1.04 | Cost towards supplying, Installation, testing & commissioning of free standing type floor mounted cubical LT motor control panel fabricated with MS sheet of suitable gauge and size duly painted with two coats of red oxide primer comprising of 400 Amp, 440V copper bus bar arrangement 4 pole consisting of following accessories:
(i) 400 Amp MCCB – 1 No. (Incoming feeder)
(ii) 250 Amp MCCB – 03Nos (outgoing feeder).
(iii) 250Amp MCCB – 01No. (As spare)
(iv) 63 Amp MCB -1 No. for lighting load and other utility load.
(v) Fully Automatic Star Delta (FASD) Starter (L&K/Havell’s/Siemen’s/Schneider/BCH make) suitable for Above pump set or more etc.- 3Nos.
(vi) 3-phase Digital display Voltmeter & Amp Meter -3 Sets, Phase indicating light R-Y-B -3 Nos.
(vii) Copper Bus Bar- 04 Pole 400 Amp, 415V Copper strip bus bar enclosed in MS sheet along with overload relay, Motor protection device (MPD), Proper power & control wiring inside by suitable size of copper conductor and wires etc. all complete set including transportation and fitting & mounting charges at P/Plant. | 1 | Set | 1 | ₹1 |
| 1.05 | Cost towards special repairing,changing & servicing of motor control panel with FASD starter and 400 Amp Incoming MCCB ,250 Amp outgoing MCCB., Copper Bus bar with S/F of following works-
i. Changing of Star contactor MNX-80-02 Nos. & Delta contactor MNX-95-02 nos. & Main Contactor MNX-95 -02 Nos (L&K/C&S/Siemen’s/Schneider make).
ii. Incoming MCCB 400 Amp – 01 No. , Outgoing MCCB 250 Amp – 02 Nos. (L&K/C&S/Siemen’s/Schneider make).
iii. Timer (3-30 sec)-02 Nos. (L&T Make).
iv. ON-OFF push buttons-04 Nos.
v. 3 Phase LED Voltmeter CI 0.5-01 Nos.
vi. 3 Phase LED Ampere meter CI 0.5 -02 Nos.
vii. Single phasing, reverse current, under voltage, over voltage protection relay-01 set each for both motor.
viii. LED Phase indicating bulb-06 Nos.
ix. Auto/Manual Selector switch-02 Nos.
x. Thermal overload Relay (45-75A) -01 No.
xi. 4 sq. mm Single core copper cable-20 mtrs. for control wiring and 16 sq. mm single core copper cable- 10 mtrs with copper lugs, tape etc. with all fittings & electrician charges at Raw Water P/Plant. | 1 | Set | 2 | ₹2 |
| 1.06 | Light wiring inside and outside of pump house with LED street light-02 Nos. (40 Watt), LED tube set- 2 Nos.
(20 Watt). | 1 | Job | 3 | ₹3 |
| 1.07 | Cost towards denting and painting of Electro-mechanical components as Motor Pump, Panel board, Sluice valve, NR Valves, Suction pipe line, common header pipe line inside Pump Chamber with primer and two coat of Metal Oil paint as required at Floating Jetty. | 1 | Job | 4 | ₹4 |
| 1.08 | Cost towards supplying, Installation and commissioning of 200KVA Servo controlled (Oil cooled) automatic voltage stabilizer suitable for output voltage of 415 volt ± 1% 3 phase 50 Hz with copper wound transformer as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling necessary monitors and user’s controls on front panel such as indication alarm, voltmeter and selector switch for measuring input and output voltage auto manual selector switch. Raise low push buttons etc. Suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided. All three phases shall be independently monitored and corrected. Following protections and indication shall be incorporated.
Over Voltage/Under Voltage Single Phasing
Cut off contactor with electronic output sensing unit Suitable change over switch and Earthing
200KVA Oil cooled Servo controlled automatic voltage stabilizer (Output 415 unit ±1%) Input 220 to 480 Volt. | 1 | No. | 5 | ₹5 |
| 1.09 | Supplying and filling of T-oil. | 1 | Ltrs | 6 | ₹6 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
BOQ_162133.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .