| Sl No | Description | Qty | Unit | SPAR INFOTECH L3 | BMG Informatics Pvt. Ltd. L1 | CB ASSOCIATE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Laying of UTP 4 pair CAT6 LSZH LAN cable in the existing surface/recessed Steel/PVC conduit as required (switch to rooms 1 run cable & OFC switch to edge switches (uplinks) 2 run cable) in Hostel Siang, IIT Guwahati. NEC & IEC guidelines to be
followed. | 13,750 | Meters | 40 ₹5,50,000 | 25 ₹3,43,750 Lowest | 30 ₹4,12,500 |
| 2.00Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Proper saddling required. Use of nail clips is not acceptable. Conduit fill should be maximum <=40% for all runs. Bidders may choose other dimensions also over and above the mentioned below but has to be quoted exact details. LIST OF APPROVED MAKES OF MATERIALS Conduits pipes & accessories – MS : BERLIA (ISI marked) PVC : WELKM/AKG /PRESTO.PLAST | ||||||
| 2.10 | 20 mm | 3,000 | Meters | 67 ₹2,01,000 | 37 ₹1,11,000 | 35 ₹1,05,000 Lowest |
| 2.20 | 25 mm | 1,500 | Meters | 76 ₹1,14,000 | 29 ₹43,500 Lowest | 42 ₹63,000 |
| 2.30 | 32 mm | 3,000 | Meters | 97 ₹2,91,000 | 44 ₹1,32,000 Lowest | 65 ₹1,95,000 |
| 3.00 | Installation of RJ45 I/O port set including punching,
testing, marking at rooms/offices etc | 320 | Nos. | 100 ₹32,000 | 50 ₹16,000 Lowest | 76 ₹24,320 |
| 4.00 | Installation, testing and commissioning of 6U/9U wall mount rack with minimum 4 nos 10 mm anchor fasteners with washers,
i. CAT6 UTP patch panel (punching, testing & ferrule numbering),
ii. Installation of 24/48 port switch & interlinking with patch cord between switch & patch panel.
iii. 1 KVA UPS for uninterrupted power to the switch | 24 | Nos. | 3,000 ₹72,000 | 1,200 ₹28,800 Lowest | 11,000 ₹2,64,000 |
| 5.00 | Laying of 2x2.5 sq mm+ 1x2.5 sq mm earth wire electrical cable including surface/recessed Steel/PVC conduit as required for power supply to UPS in the installed wall mount racks
LIST OF APPROVED MAKES OF MATERIALS
Wire (Copper conductor): FR copper wire (FINOLEX / HAVELLS / RR KABEL / BERIA / KEI | 400 | Meters | 200 ₹80,000 | 120 ₹48,000 Lowest | 185 ₹74,000 |
| 6.00 | 2 nos 3 pin 16/6A socket with one 16A switch within a 6 moduler box with face plate etc as required.
LIST OF APPROVED MAKES OF MATERIALS
Switch & Socket: MK / CRABTREE / LEGRAND /
SCHNEIDER / PHILIPS/NORTH WEST | 12 | Nos. | 996 ₹11,952 | 1,000 ₹12,000 | 950 ₹11,400 Lowest |
Tender Value
Refer Docs
EMD Value
₹38,600
Closing Date
17 Aug 2026, 12:00 pmClosed
HoS (Store and Purchases)
Store and Purchases Section
Laying of UTP 4 pair CAT 6 LSZH LAN cable in the existing surface or recessed Steel or PVC conduit as required etc. in Siang Hostel, IIT Guwahati
2026_IITG_919381_1
EPT/SNP/CC/COY-26.3034
Open Tender
Electrical Works
Works
35 days
Siang Hostel, IIT Guwahati
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹38,600
Yes
7 Sept 2026
27 Jul 2026
18 Aug 2026
27 Jul 2026
17 Aug 2026
7 Aug 2026
28 Jul 2026 - 4 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Laying of UTP 4 pair CAT6 LSZH LAN cable in the existing surface/recessed Steel/PVC conduit as required (switch to rooms 1 run cable & OFC switch to edge switches (uplinks) 2 run cable) in Hostel Siang, IIT Guwahati. NEC & IEC guidelines to be
followed. | 13,750 | Meters | - | - |
| 2Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Proper saddling required. Use of nail clips is not acceptable. Conduit fill should be maximum <=40% for all runs. Bidders may choose other dimensions also over and above the mentioned below but has to be quoted exact details. LIST OF APPROVED MAKES OF MATERIALS Conduits pipes & accessories – MS : BERLIA (ISI marked) PVC : WELKM/AKG /PRESTO.PLAST | |||||
| 2.1 | 20 mm | 3,000 | Meters | - | - |
| 2.2 | 25 mm | 1,500 | Meters | - | - |
| 2.3 | 32 mm | 3,000 | Meters | - | - |
| 3 | Installation of RJ45 I/O port set including punching,
testing, marking at rooms/offices etc | 320 | Nos. | - | - |
| 4 | Installation, testing and commissioning of 6U/9U wall mount rack with minimum 4 nos 10 mm anchor fasteners with washers,
i. CAT6 UTP patch panel (punching, testing & ferrule numbering),
ii. Installation of 24/48 port switch & interlinking with patch cord between switch & patch panel.
iii. 1 KVA UPS for uninterrupted power to the switch | 24 | Nos. | - | - |
| 5 | Laying of 2x2.5 sq mm+ 1x2.5 sq mm earth wire electrical cable including surface/recessed Steel/PVC conduit as required for power supply to UPS in the installed wall mount racks
LIST OF APPROVED MAKES OF MATERIALS
Wire (Copper conductor): FR copper wire (FINOLEX / HAVELLS / RR KABEL / BERIA / KEI | 400 | Meters | - | - |
| 6 | 2 nos 3 pin 16/6A socket with one 16A switch within a 6 moduler box with face plate etc as required.
LIST OF APPROVED MAKES OF MATERIALS
Switch & Socket: MK / CRABTREE / LEGRAND /
SCHNEIDER / PHILIPS/NORTH WEST | 12 | Nos. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.56 MB
BOQ_966164.xls
BOQ • 0.29 MB
corrigendum.pdf
PDF • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .