Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance PLOT NO 484 NEAR LAXMI NARAYAN MANDI NAYAPALLI BHUBANESWAR ORISSA 751012 | KHORDHA | ODISHA | 751012 | Admitted-Finance |
| 3 | Admitted-Finance 1 2 45 1 STREET NO 2 KAKATEEYA NAGAR COLONY HABSIGUDA HYDERABAD 500 007 | HYDERABAD | HYDERABAD | TELANGANA | 500007 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance P B NO 14 UNIT IV MARKET COMPLEX SHOP NO W 5 BHUBANESWAR 751001 ODISHA | BHUBANESWAR | KHORDHA | ODISHA | 751001 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
1 Dec 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PROFESSOR BPCL BIOFUEL CHAIR
CAET , OUAT, BHUBANESWAR
Supply of Instruments/Equipments
2020_OUAT_63614_1
01/BPCL OUAT DT.07.11.2020
Open Tender
Laboratory Equipment
Item Wise
60 days
OUAT Bhubaneswar
Please refer Tender documents.
3 documents required · 3 mandatory
₹1
PROFESSOR BPCL BIOFUEL CHAIR
14 Dec 2020
7 Nov 2020
3 Dec 2020
7 Nov 2020
1 Dec 2020
7 Nov 2020
60 days
Amount
Isoperibol Bomb Calorimeter for Solid & Liquid Fuels
In accordance with DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711, ASTM-D5468. Instrument must be CE certified
A temperature-controlled water jacket with a built-in/ integrated circulating system and an electric chiller.
An oxygen bomb with an oval/ cylindrical bucket which fits into the insulating water jacket.
A built-in automatic system/ manual for charging the bomb with oxygen.
A high precision electronic thermometer.
A bright, soft touch screen displays for data entry and operation control
Special communication ports for printer, computer and network (LAN) connections, etc.
Dynamic and time-controlled modes; Automatic bucket filling, & draining, automatic ignition and calculation of calorific value; result is display edit measures Gross Calorific value
Suitable for solid & liquid fuels. Precession /RSD – 0.1% and measurement time 10 to 15 minutes
Manuals: One set of manuals with all details of parts should be supplied
With consumables spares required for minimum 1000 tests. Suppliers must supply the balance (220gm & resolution 0.1mg) and one oxygen cylinder (47lt) with regulator.
TGDTA
2.1 Thermo gravimetric (Proximate) Analyzer to determine ash and any other materials.
2.2 The analysis method should comply BIS/ASTM/ISO/DIN Standard Test Method for Proximate analysis by instrumental procedure for Moisture and ash determination.
2.3 TGA analysis with DSC curve provision should be there
2.4 The thermo gravimetric analyzer should meet the following technical specifications.
2.5 Sample weight -up to 200 -400 mg
2.6 Balance –Balance should be sensitive to 0.2ug, microgram, and should be integrated with the furnace.
2.7 Display & Control unit – built in display & control unit or PC Controlled [for PC Controlled type TGA, vendor must supply latest generation i7 PC along with the instrument.
2.8 Working Temperature –Ambient temperature to 1000 degree centigrade or more.Cooloing from 1000 0C to 500C should reach within 15-20 min.
2.9 DTA measurement range- should be ±1000 µV or better
2.10 DTA RMS noise: should be 0.03 µV or better
2.11 Temperature accuracy - ±0.1˚C (or better) at the set point. The furnace temperature must be calibrated, checked & adjusted in the field for any doubt.
2.12 Scan rate:0.1 ˚C to 150 ˚C per min with secure and controlled purged arrangement
2.13 Ramp rate – 10 to 50 degree centigrade per minute (programmable as and when required) or equivalent.
2.14 Sample size – powdered sample.
2.15 Ventilation – System should have device to expel combustible gases from instruments
2.16 Working atmosphere – Both oxidizing and inert. Provision shall be made to introduce a sweep gas or a reactant gas, and to remove product of drying, devolatilization or combustion
2.17 Crucible – The sample Carousel, balance pedestal, crucible and the crucible covers must be made of ceramic [non-metallic] material or refractory material.
2.18 Furnace – The furnace should have maximum temperature control up to 1000 degree centigrade
2.19 Precision - Instrument must perform a standard weight loss for an inert sample with a precision of ± 0.2% RSD (or better) at different temperature and gas flow rate.
2.20 Power requirement - 230 VAC ± 10%, 50 Hz, Single Phase
2.21 Manuals: One set of manuals with all details of parts should be supplied
2.22 Suitable PC and printer with all original genuine software should be supplied along with the system. The system software should have the option to derive the DSC analysis from DTA
2.23 Windows based user friendly latest analytical software for TGA analysis
2.24 Available Input power: 220 V one phase/three Phase, 50 Hz
2.25 Should provide all requirements for testing minimum 100 trial samples during installation
2.26 Suitable Online UPS with minimum 30-45 m in back up
Mini Briquetting machine
3.1 Electric Motor = 1 HP Single Phase
3.2 Capacity = 30 to 40 Kgs/Hr
3.3 Output Material Size = 20 to 30 mm round type / cylindrical briquettes
Biomass Shredding machine
4.1 Used For Garden Waste And Kitchen Waste
4.2 Dual Shaft Shredding Machine
4.3 Capacity - 100 Kg To 5000 Kg
4.4 Semi-automatic
4.5 Shredding Capacity - 1-500 Kg/h
4.6 Electric Motor - 5hp
4.7 Material Grade - Mild Steel
Gas Mass Flow Meter
5.1 Mass flow controller is required to control syngas (H2, CO, CO2, CH4& Higher hydrocarbons)
5.2 Composition of syngas: 40% H2, 29% CO, 20% CO2, 11% CH4.
5.3 Flow range: 5 SLPM with standard display
5.4 Pre-calibrated minimum for 20 different gases and 10 gas mixtures.
5.5 Accuracy: ± 0.8% reading + 0.2% with repeatability: ± 0.2% full scale
5.6 Operating range: 0.5% to 100% full scale measurement, control with response time 100 ms
5.7 Standard conditions: 25°C & 14.696PSIA mrc, operating temp: 10 to +50°C
5.8 Zero/span shift: 0.02% full scale, humidity range: 0 to 100% with controllable flow rate: 102.4%
5.9 Maximum pressure: 145PSIG, power supply: 12 to 30VDC
5.10 DC power supply 100 to 240V AC to 24VDC global adaptor
5.11 Complete with all accessories, packaging, transport, insurance, installation & training regarding operation (all) should be made by the supplier
Portable mini Gas Analyser
6.1 Measure the producer gas obtained from biomass (carbon monoxide(20 to 40%, hydrogen (5 to 10%), carbon dioxide(10 to 20%) , nitrogen ( 20 to 60%) and methane ( 5 to 15%)
6.2 Display: LCD
6.3 Communication port: RS232
6.4 Calibration: Automatic or manual
Fractional Distillation Unit
7.1 Capacity:1 Litres
7.2 Distillation Column Diameter 8 mm or more
7.3 Distillation Column Length : Minimum 90 cm
7.4 Condenser : Jacket type with secondary Condenser with automatic Cooling and Heating
7.5 Boiler : Electrical Heater type
7.6 Boiler Sizes : 100, 250, 500 and 1000 ml glass
7.7 Spinning Band: Teflon &Stainless Steel
7.8 Fraction Collector: Minimum 8 Place
7.9 Vacuum Operation: automatic
7.1 Safety Marks : CE Marked
7.11 As per Indian standard
7.12 The system should be complete with all accessories
7.13 Suitable online UPS to be supplied with the system
Rotary Evaporator with vacuum Pump
Rotary Evaporator
8.1 Rotary Evaporator with Hand Lift provision , 1 liter Evaporating flask and 1 liter Receiving flask should be came as standard
8.2 Height adjustment provision for evaporating flask should be 150 ~160 mm
8.3 Evaporating Flask angle can be adjusted in between 20° to 80° or better
8.4 Universal Heating bath temperature ambient to 200°C or more
8.5 Rotation Speed 20-280 RPM or better
8.6 LCD Display
8.7 Provision for locking feature of set parameters such as temperature and rpm
8.8 Heating bath material should be made of stainless steel which can accommodate 5 litre of evaporating flask and allows for 200mm horizontal extension
8.9 Bath Temperature Accuracy: ±1°C
8.10 Heating bath with safety handles and drain spout should be available
8.11Bath over temperature cut-off automatically if temperature overshoots by 5°C or runs in dry condition
8.12 Secondary over temperature cut-off at 250 ° C
8.13 Condensate surface: 1400cm2 or more
8.14 With clamp stand for the condenser as standard supply
8.15 Protection class for control panel: IP 42, prevents from splash water spillage and dust protected
8.16 Protection class for heating bath power socket: IP 67, which prevents against corrosion and short-circuits
8.17 All parts which are in contact with the media should be consist of GRAPHITE filled PTFE /FKM Vacuum seal
8.18 Designed vapor tube with sleeve to add more strength and easily removes from drive
8.19 Voltage/frequency 220-240V/50 Hz
8.20 CERTIFICATION: Should have ISO and CE certification
Vaccum Pump
8.21 Two stage diaphragm pump made of chemical resistance material
8.22 Suction Capacity in m3 / hour: 0.75 or more
8.23 Ultimate Vacuum in mbar: 12 or less
8.24 Vacuum should be controlled via valve operated vacuum controllers
8.25 Sound pressure level up to 1 m distance-- 40 DBA or less
8.26 Protection Class- IP-42 or better
8.27 Supply Voltage (V / Hz ):230 /50
8.28 CERTIFICATION: Should have ISO and CE certification
Soxhlet extraction unit with heating unit
Soxhlet extraction unit (Large):
9.1 Joint: Joint ST/NS extractor bottom, Joint ST/NS extractor top
9.2 Extractor Internat Diameter: 50 mm
9.3 Extractor volume: 200 mL
9.4 Flask volume: 300 mL
Soxhlet extraction unit (Medium):
9.5 Joint: Joint ST/NS extractor bottom, Joint ST/NS extractor top
9.6 Extractor Internal Diameter: 38 mm
9.7 Extractor volume: 85 mL
9.8 Flask volume: 250 mL
Heating mantle for Soxhlet extraction:
9.9 1 test and 3 or 6 heating units (positions) for multi-tests that can perform testing of 1, 3 or 6 samples at one time accordingly.
9.10 Each position should fit with individual electronic controller
9.11 Machines should accommodate 50 ml to 1000 ml flasks and can be customized further
9.12 System should be equipped with a convenient stopcock on the soxhlet body which allows solvent to be drained into a storage reservoir after the extraction process is complete
9.13 For flasks: 6 X 500 ml
9.14 Width: 1450mm
9.15 Depth :285 mm
9.16 Height: 130 mm
9.17 Power:1200 watt
Ultrapure water (deionizer)
10.1 The highest purity level of water according to ASTM D1193
10.2 Can provide both ultrapure (Type I) and pure (Type II/ Advanced RO) water
10.3 Electrical Conductivity Max. (µS/cm @ 25°C) 0.056
10.4 Electrical Resistivity Min. (MΩ-cm @ 25°C) 18.0
10.5 TOC ≤ 5 ppb
10.6 Particulate (size >0.22µm) <1 particulate/mL
10.7 Bacteria <0.01 CFU/mL
10.8 Pyrogens(endotoxins) <0.01EU/mL
10.9 Rnase<1pg/mL
10.10 Dnase<5pg/mL
10.11 Flow rate upto 2L/min
10.12 Sodium max. µg/l 1
10.13 Chloride max. µg/l 1
10.14 Silica removal (%)>99.9
10.15 Requires the use of a 0.2µm membrane filter
10.16 Ionic rejection 97-98%
10.17 Organic rejection for MW> 200 Dalton >99.0%
10.18 Particulates rejection >99%
10.19 Production flow rate 8L/h; 16L/h
10.20 Delivery flow rate: from storage tank tap up to 2.5 L/min
Recirculating chiller
11.1 High-brightness, large color 5.5-inch LCD display
11.2 Molded water tank, uni-body with 316 stainless steel, anti-rust, anti-corrosion
11.3 Motor driven mold turbine quiet pump 10L/min fully realized hydro-power separation
11.4 Compact structural layout with removable grille for easy maintenance and drainage
11.5 Using advanced fuzzy PID temperature control technology, it can accurately and quickly achieve stable temperature control effect
11.6 Compressor refrigeration, R134a environmentally friendly refrigerant, avoiding environmental pollution and harm to experimenters
11.7 Multiple protection design: over current protection, high and low temperature protection, over temperature protection, low liquid level sound and light alarm, prevent dry burning protection
11.8 Temperature control range - 5℃~100℃
11.9 Temperature stability - ± 0.05℃
11.10 Display resolution - 0.1℃
11.11 Temperature control method - Fuzzy PID
11.12 Temperature sensor - PT100
11.13 Heating Power - 2000W
11.14 Cooling Power - 1500W
11.15 Refrigerant - R134a
11.16 Pump flux - 10L/min
11.17 Pump pressure - 0.35 bar
11.18 Volume - 10L
11.19 Dimensions LxWxH(cm)-555mm×350mm×750mm
11.20 Power supply 220 VAC ±10% 50Hz
11.21 Working condition-10℃~25℃
11.22 Weight - 40kg
Refrigerated centrifuge
12.1 Max Speed (RPM) : 20000
12.2 Max RCF :37570 Max
12.3 Max Tube size:250
12.4 Max. Capacity:1200
12.5 Temperature: -8 °C
12.6 Capacity: 4 to 6 x 85 to250 ml (Fixed Angle Rotor) (Max Speed: 9500 RPM & Max RCF: 12000 )
12.7 Max capacity: 4x 600ml (Swing Out Rotor) (Max Speed: 4800PRM & Max RCF: 4740RCF)
12.8 Capacity:8 x 50 ml (Angle head Rotor) (Max speed:16000 RPM and Max RCF: 30020
12.9 Capacity : 12 x 15 ml (Angle head Rotor) ( Max Speed:20000RPM and Max RCF:37570)
12.10 Capacity:24 x 1.5 ml (Angle head Rotor) (Max speed: 20000 RPM and Max RCF:37570
12.11 Noise level: <56 dB(A) or less
12.12 Powered lid locking
12.13 Ergonomic control and information panel
12.14 Easy rotor changing
12.15 98 program storage spaces
12.16 Protection against unauthorized operation / modification of stored programs
12.17 Switch of centrifuge run time from “at start” (commencement at start) to “at speed” (start when nominal speed is attained)
12.18 Imbalance switch-off
12.19 Automatic rotor recognition
12.20 Emergency lid lock release Lid locking and holding during rotor run
12.21 Motor overheating protection
12.22 Stand-by cooling SAFETY
12.23 Lid dropping protection
12.24 Electrical Supply: As per Indian Standard
12.25 Certification: IVD, CE & ISO
12.26 Local service support should be available.
Filtration setup
13.1 1 x vacuum pump (in pump kit only)
13.2 1 x 1m length of heavy walled rubber tubing
13.3 2 x cable ties (to affix the tubing to the pump inlet securely)
13.4 1 x 250ml Pyrex Buchner flask
13.5 1 x set of filter cones (to connect the flask to the funnel with an airtight seal)
13.6 1 x procelain Buchner funnel to fit 7cm filter papers
13.7 1 x retort stand set (to hold the flask steady during filtration)
Lab Wiley grinder
14.1 Heavy Duty Willey Mill is mounted on a complete enclosed Iron Frame
14.2 The base contains with 1 H.P. Electric Motor, Single Phase to work on 220/230 Volts A/C
14.3 Four Steel Knives bolted to a rotor to work against SIX KNIVES BOLTED WITH GRIDING CHAMBER. Hinged door facilitates cleaning by affording easy access to grinding chamber which 200 mm dia x 75 mm deep
14.4 Feeding rate is controlled by a sliding shutter at the lower end of hopper. The Sieves are of Brass-Sheet mounted on aluminum frames so that samples cannot enter receiver without passing through the screen
14.5 3 Sieves with No;20 , 40 , & 60 mesh brash sieve
HPLC column for sugar analysis with guard column
Aminex HPX-87P column with guard column for sugar analysis
15.2 Prepacked HPLC carbohydrate analysis column
15.3 Lead form, 9 µm particle size, 8% cross linkage
15.4 pH ranges 5-9
15.5 Guard column: with ionic form H+ /CO3 - deashing guard column (30X 4.6 mm guard column, lead form pH ranges 5-9, for Aminex HPX-87P column)
Aminex HPX-87H column with guard column for sugar, alcohol and acid analysis
15.6 300x7.8 mm,prepacked HPLC carbohydrate analysis column, hydrogen form
15.7 9 µm particle size, 8% cross linkage, pH range 1-3
15.8 Guard column:30x4.6 mm, guard column, hydrohen form, pH range 1-3, for Aminex hydrogen form columns
Spectrophotometer with microplate reader
17.1 Single compact instrument with both UV/Vis and fluorescence spectrometer and allowing quantification of sample volumes from 'Microlitres to Millilitres’.
17.2 Spectral band width: < 4 nm
17.3 Photometric measuring range: 0 A to 3.0 A at 260 nm
17.4 Random error: ≤ 0.002 if A = 0 ≤ 0.005 (0.5 %) if A = 1
17.5 Systematic error: ± 1% if A = 1
17.6 Display: VGA TFT-Display 5.7"
17.7 Instrument should not have warming up time
17.8 System should be capable of determining very low concentration of biomolecule using commercially available fluorescent dyes for dsDNA, ssDNA, Oligo, RNA & protein.
17.9 Should have in-built pre-programs for nucleic acids and protein quantification by fluorescence intensity using dyes such as PicoGreen®, OliGreen®, RiboGreen® and NanoOrange®.
17.11 Fluorescence intensity should be across a range of 0.5nM - 2,000nM fluorescein
17.12 Detection range for dsDNA should be 1pg/µL to 1000ng/mL in fluorescence mode and 2.5ng/µL to 1500ng/μL in absorbance mode
17.13 Measuring principle should be confocal filter fluorimeter with reference beam
17.14 Should have the combination of LED as light source along photodiodes as beam receiver
17.15 Random error should not exceed ± 2% at 1 nm fluoresce (emission wavelength 520 nm)
17.16 Absorbance optics must have the combination of xenon flash lamp with holographic aberration-corrected concave grating and receiver as CMOS photodiode
17.17 Operating principle must be with two beams: Absorption single-beam spectrophotometer with reference beam
17.18 Should be compact & stand-alone system to handle sample volume ranging from 1.5μL to 4mL.
17.19 UV/Vis wavelength range from 200nm to 830nm, with spectral scanning feature.
17.20 System should be supplied with at least 200 numbers of UV permissible plastic cuvettes of 50μL sample volume.
17.21 Must allow rapid and reliable quantification of Nucleic acids and proteins, OD600, dye methods (to calculate the FOI for both nucleic acid & protein).
17.22 Should allow acquire data at user-defined wavelengths from 200 nm to 830 nm and at user preferred path length
17.23 Concentration via standard series must have curve fit evaluations viz., Regressions (linear, cubical, quadratic), and Interpolations (linear & Spline) with curve sections in detail with view directly on the instrument display
17.24 Should allow transfer of measured data to PC by connecting the device directly to PC without any additional software in addition to transfer the data via USB stick
17.25 Must have evaluation methods with factor, standard or standard series
17.26 Must have Multi – wavelength, Dual-wavelength applications with subtraction and division analysis
17.27 Direct operation on the device, with no requirement for PC
17.28 Measuring results (>1,000) can be saved directly on the device. >100 method programs in memory.
Microplate reader
17.29 With attached 96 well plate titer plate reader system
17.30 Low-volume samples with the Plate (2 µL)
17.31 Ultra-fast spectrometer to read 220 to 1000 nm in under 1 second per well
17.32 Compatible with all microplate formats up to 1536-well
17.33 A standard cuvette port for individual samples
17.34 Multi-mode shaking: linear, orbital, and double orbital
SARTECH INTL
KOLOSH INSTRUMENTS
BLUE OCEAN E-COMMERCE PRIVATE LIMITED
LAB CHEMICALS PRIVATE LIMITED
INKARP INSTRUMENTS PVT LTD
PerkinElmer India Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .