SITC of HVAC system and BMS for BSL3 Lab at NABI
2020_NABI_572735_1
NABI/7(224)/2020-WORKS
Open Tender
Electrical Works
Works
42 days
NABI CAMPUS
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
NABI
₹65,708
Yes
21 Dec 2020
22 Jul 2020
6 Aug 2020
22 Jul 2020
5 Aug 2020
22 Jul 2020
Supplying, installing, testing and commissioning of factory built Floor mounted double skin type air handling units with thermal break profile made of 2" thick panels consisting of pre plasticized G.I. casing of thickness 0.63 mm outside layer and 0.63 mm plane inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with SISW plug type blower in form of fan wall (2 blowers), each fan in will be separated by GI partition. All the fans in fan wall will be syncronized in such a way so as to meet the required CFM & static pressure, These fans will be operated by a single or multiple VFD ( IP 20 encloser), coil section will have 8 Row deep Chilled water cooling coil, 4 Row deep heating coil(water), 6 Row deep DX coil for VRV in coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron, Fine filters having efficiency 99% down to 5 micron, HEPA Filters with 99.99% efficienciency down to 0.3 micron, drive package with TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with drain connections with drain valve, stainless steel drain pan, thermometers and pressure gauge at the inlet and outlet of the coils, necessary vibration isolation arrangement etc, complete as per specifications of following capacities: AHU shall be with canopy.AHU No 1 (in 2 tier) 3950 CFM / 110 mm static ( 2 fans each fan of 3950 CFM) 40 TR cooling capacity ( 8 row deep coil) , 60 KW heating capacity (2 row deep coils for reheat and 2 row of Heating coil shall act for winter heating to give full heating capacity), 6 row deep DX VRV coil, 125 mm static, 2 nos plug fans each of 3950 CFM.
Supplying, installing, testing and commissioning of factory built Floor mounted double skin type Exhaust units made of 1" thick consisting of pre plasticized G.I. casing of thickness 0.63 mm outside layer and 0.63 mm plane inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with SISW plug type blower in form of fan wall (2 blowers), each fan in will be separated by GI partition. All the fans in fan wall will be syncronized in such a way so as to meet the required CFM & static pressure, These fans will be operated by a single or multiple VFD ( IP 20 encloser), filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron, Fine filters having efficiency 99% down to 5 micron, HEPA Filters with 99.99% efficienciency down to 0.3 micron, drive package with TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, UVGI bank in exhaust passage or intens complete with not less than 254 nM frequency necessary vibration isolation arrangement etc, complete as per specifications of following capacities: NOTE: The filters shall have bag In and Bag Out provision to avoid contamination.EU No 1, 4400 CFM (each fan of 4400 CFM each), 110 mm static, 2 nos plug fans each of 4400 CFM.
Lifting, shifting, positioning, vaccumization, installation, testing & commissioning of existing outdoor VRV units of rating 14.83 TR (18 HP)
Supply & Filling of Refrigerant R410A in Outdoor VRV units of rating 14.83Tr (18HP)
Supply and Installation of Expansion kit for 20 HP coil
Supply & Fixing of MS Heavy duty VRV Outdoor Units stands
Supplying, installing, testing and commissioning of DDC Controller with I/O module, expandable to meet the IO summary listed, The controllers shall be minimum 32 bit Double microprocessor based standalone working on TCP/IP on Bacnet IP with integral web browser, calender function complete with day, month, week, year etc, real time clock & 1 second scan time. DDC working on 230V AC are preferred. The DDC's shall be capable of peer to peer communication without help of communication controller / router / system interface controller / PC and shall communicate with the building LAN directly. These shall come with lockable mounting cabinets duly powder coated connector strip, internal wiring and space to house controller & relays, connector strip step down transformer, MCB, internal wiring. (Contractor shall confirm his I/O provision w.r.t requirement on basis of data point) on AHRAE approved Bacnet protocol only. DDCs shall work on either 230V power supply or shall contain UL listed SMPS in the panel. Controller shall have 1 RS-485 Port for the Integration of VFD, Controller shall support 96 Points.DDC Controller with 15% Spare as per I/O summary attached. The BMS system shall give an alarm with hooter in case of failure of HVAC system.
Supply, Installation Testing and commissioning of Differential Pressure Switch Across Blower (40-400 Pa). Sensor shall have Max. Operating Pressure 5000 Pa & Membrane Material: Silicone
Supply Installation testing and commissioning of Water Flow Switch having Operating Pressure: 10Kgf/Cm2 & Withstand Pressure: 17.5Kgf/Cm2
Supply Installation testing and commissioning of Differential Pressure Switch Across Filter (20-200 Pa). Sensor shall have Max. Operating Pressure 5000 Pa & Membrane Material: Silicone with suitable IP65 covering to suit outdoor installation
Supply Installation testing and commissioning of Duct Temp. & RH Sensor with +/- 2% Accuracy.
Supply Installation testing and commissioning of Wall Mount Room Temp. / RH / Delta P with 7- Segment Display with Analog Output: Temp. Sensor: 10KΩ NTC Thermistor Sensor; Temp. range: 0-50°C, Accuracy: ±0.2°C; Output: 4-20 mA/ 0-10 VDC Humidity Sensor: Thermoset polymer based capacitve sensor; Range: 0-100% RH; Accuracy: ±2% RH; Output: 4-20 mA/ 0-10 VDC Differential Pressure: MEMS piezo resistive differential sensor; range: ±250 Pa; Accuracy: ±0.5% FS; Output: 4-20 mA/ 0-10 VDC.
Supply Installation testing and commissioning of Air Velocity Sensor
Modification and Integration of existing Honeywell DDC Controller & Software.
Supply, Installation, Testing and Commissioning of variable frequency drives for Air Handling Units. Variable frequency drives shall be provided with necessary sensors and transmitters complete with control wiring in all respect as required and as per specifications. VFDs shall have built-in harmonic filters. The drives shall be suitable for the following motor ratings. VFDs shall be housed in precoated, vandal proof enclosure with On/Off Push Buttons, Phase indication lights, A/M Switch and with adequate provisions for ventilation using a fan. The VFDs shall be able to receive the signals from multiple/combination of duct static pressure sensors/Temp. sensors and to ramp the speed of the motor.VFDs shall be suitable to take feed back and connectivity from all the DPS as mentioned below against each motor rating to facilitate averaging activity by VFD. Quoted price shall be inclusive of return air temperature sensor/Pressure Sensors and necessary electrical switches including change over switch & copper cabling for integration with the AHU panel. VFDs shall be installed within Electrical panels as described under Section 'Electrical Works'. Overall protection of VFDs with Panels shall be IP-54. (rating: 7.5HP)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water and hot water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above(80 mm dia MS pipes with 50 mm thick insulation).
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water and hot water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above(40 mm dia MS pipes with 50 mm thick insulation).
Supplying, fixing, testing and commissioning of following valves, in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified (80 mm dia Valves)
Supplying, fixing, testing and commissioning of following valves, in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified (40 mm dia Valves)
Supplying, fixing, testing and commissioning of following valves, in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.(80 mm dia Valves)
Supplying, fixing, testing and commissioning of following valves, in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.(40 mm dia Valves)
Supplying, fixing, testing and commissioning of following strainers in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.(80 mm dia)
Supplying, fixing, testing and commissioning of following strainers in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.(40mm dia)
Supplying, installation, testing and commissioning of Auto air vent as per the technical specs and as per the site requirement
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometres.
Supply Installation Testing and commissioning of Magnehelic gauge -30 to +30 pascal range with SS Box knobs and tube etc complete as per the directions of Engineer In charge
Providing and fixing in position the following GI B class pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated as per specifications.50 mm dia pipes
Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping between AHU & outdoor VRV units complete with fittings, with all piping properly supported, jointing/brazing including accessories, insulated with Class-0 closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement.(28.58 mm dia (OD)(Hard drawn) with tube thickness minimum 1.2mm with 19 mm thick insulation)
Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping between AHU & outdoor VRV units complete with fittings, with all piping properly supported, jointing/brazing including accessories, insulated with Class-0 closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement.(15.86 mm dia (OD)(Soft drawn) with tube thickness minimum 1.2mm with 19 mm thick insulation)
Supply, installation, balancing and commissioning of factory fabricated GSS sheel metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Duct Size 0- 750 mm (24 Gauge TDF joints) with Silicon sealant, Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheel metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Duct size 751 - 1500 mm (22 Gauge TDF joints) with Silicon sealant, Thickness 0.80 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheel metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Duct Size 0-750 mm (24 Gauge )/ MS Flange Silicon sealant, Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheel metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Duct size 751-1500 mm (22 Gauge MS Flange Silicon sealant), Thickness 0.80 mm sheet
Supply, Installation, Testing of 125 mm deep antivibration flexible joints at the outlet of air handling units / fans. Flexible connections shall be constructed using imported fire retardant fabric with extruded aluminium frame / flange on both sides of approved make.
Supply, installation, testing and balancing of powder coated extruded aluminium square shape ceiling diffusers with removable core and anti smudge ring as per specifications
Supplying & fixing of opposed blade aluminium construction volume control dampers in supply air duct collars as per approved drawings and specifications.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc as per specifications.
Supplying , fixing, testing and commissioning of fire damper in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and are not externally mounted. The damper shall also be closed in the event of fire signal complete as required ans as per specifications.Note: Fire dampers shall be supplied with sensors/actuators/control etc duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper
Supplying , fixing, testing and commissioning of Actuators of fire damper in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and are not externally mounted. The damper shall also be closed in the event of fire signal complete as required ans as per specifications
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required: 19 mm thick insulation for Supply Air ducts with GC Cloth
Supplying and laying of following 1100 volt grade XLPE insulated and PVC sheathed aluminium conductor armoured Aluminium cables on cable trays, in ducts/shafts, on walls clamped to wall with suitable clamps, saddles, and fixing bolts, or laying in ground including cost of digging, backfilling with brick and sand protection etc.complete as per the site requirement(4C x 10 sq.mm for AHU/ EU Motor)
Supplying and laying of following 1100 volt grade XLPE insulated and PVC sheathed aluminium conductor armoured Aluminium cables on cable trays, in ducts/shafts, on walls clamped to wall with suitable clamps, saddles, and fixing bolts, or laying in ground including cost of digging, backfilling with brick and sand protection etc.complete as per the site requirement(4C x 16 sq. mm for VRV ODUs)
Supply & laying of 1.1kV grade Copper conductor, PVC insulated ISI marked heavy duty armoured Cable (IS:1554-1976) (Part-I) with end termintaion including thimbling, glands etc. complete as per the site requirement(3.0 C x 2.5 sq.mm)
Supply & laying of 1.1kV grade Copper conductor, PVC insulated ISI marked heavy duty armoured Cable (IS:1554-1976) (Part-I) with end termintaion including thimbling, glands etc. complete as per the site requirement(4.0 C x 2.5 sq.mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, with GI cover, joined with connectors, fixed on the floor or on wall with painted MS Angular supports including G.I. bolts & nuts, fasteners etc. complete as per the site requirement.(300 mm width X 50 mm depth X 1.6 mm thickness)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, with GI cover, joined with connectors, fixed on the floor or on wall with painted MS Angular supports including G.I. bolts & nuts, fasteners etc. complete as per the site requirement.(225 mm width X 50 mm depth X 1.6 mm thickness)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supply, Laying, Testing and Commissioning of Cat-6 in 25 mm PVC Conduit with complete Accessories.
Supply, Laying, Testing and Commissioning of 2 C X 1.5 Sq.mm Shielded Cable in 25 mm PVC Conduit with complete Accessories.
Supply, Laying, connecting, testing and commissioning of new control cum transmission copper flexible cable of size 2 core x 1.0 sq mm in suitable size PVC conduits between AHU & VRV outdoor units and to central remote, if applicable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.(4C X 10 sq. mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.(4C X 16 sq. mm)
A.V.ENGINEERS PVT LTD
SMD SOLUTIONS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .