| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.1 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹90.0 L+₹10.2 L (12.7%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹94.3 L+₹14.5 L (18.2%)Rejected-Finance 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | Rejected-Technical DANDAMUDI ENCLAVE PETBASHEERABAD HYDERABAD 500067 | HYDERABAD | HYDERABAD | TELANGANA | 500067 | - | Rejected-Technical Not meeting eligibility criteria, requisit documents does not submitted as per NIT |
Tender Value
₹82 L
EMD Value
₹1.5 L
Closing Date
12 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
AUGMENTATION OF ELETRIC SUPPLY AT AF STATION UNDER GE AVADI
2022_MES_552072_1
87673/AVD
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Avadi Chennai
As per NIT
8 documents required · 8 mandatory
₹1,000
GE Avadi
₹1.5 L
Yes
3 Dec 2022
15 Sept 2022
17 Oct 2022
15 Sept 2022
12 Oct 2022
30 Sept 2022
15 Sept 2022 - 26 Sept 2022
Amount
BOQ UPLOADED ON 29 SEP 2022
BOQ ITEMS
TRANSFORMERS INCLUDING ALLIED WORKS Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Laying of Fine Seived Excavated Dry Soil including spreading / leveling as cushioning for underground cables in trenches all as specified and as directed.
Supply and laying reinforced precast concrete cable cover, class HV, type 1, Flat, size 300 mm x 180 mm x 40 mm complete all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B of size 230x115x75mm for cable protection all as specified and as directed.
Taking out HT UG Cable XLPE insulated with multistranded aluminium conductor armored with galvanized steel wire / taps 11000 volts grade of size 3 core 95 sqmm from trenches etc complete all as specified and as directed. Note : Earth work excavation shall be measured and paid for separately
Supply and laying in trenches/poles/wall etc HT UG Cable XLPE insulated with multistranded aluminium conductor armoured with galvanised steel wire / taps 11000 volts grade conforming to IS specifications of size 3 core 95 sqmm complete all as specified and as directed. Notes :-Earth work excavation ,sand cushioning & cable cover shall be measured and paid for separately
Supply and fixing Outdoor termination heat shrink type joint for 11 KV(Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE / armoured heavy duty cable with aluminium conductor of size 95 sqmm complete all as specified and as directed.
Supply and fixing Straight through heat shrink type joint for 11 KV(Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE / armoured heavy duty cable with aluminium conductor of size 95 sqmm complete all as specified and as directed.
Supply, installation testing and commissioning of outdoor type distribution transformer, level-2, converter duty type low losses as per ECBC (3star rating in) of Minimum 100 KVA, 0.433/11 KV, 3 phase, 50 HZ,ONAN cooled, Oil immersed, copper double wound, outdoor type, complete with first fill of oil and other standard fitting/ accessories and seven point off load at changer (tapping range +/- 7.5% in steps of 2.5% each)with VECTOR GROUP Dyn-11 or as per inverter supplier recommendations as per IS 1180 2014 including HV Cable Box (Without Cable Glands) LV Cable Box (Without Cable Glands), Magnetic oil level gauge, Conservator with oil filling hole with cap and drain plug and wit built in Buchholz Relay with alarm and trip contact and shut off valves. Oil temperature indicator 150 mm dia with alarm and trip contact. Oil level indicator with minimum level marking. The mometer pockets with thermometer. Silica gel breather Air Release plug. Lifting Lugs Earthing terminals Bi-directional Rollers Anodized aluminum rating and diagram plate all as specified and directed. Note : The transformer shall be erected on PCC platform .The PCC platform shall be measured and paid for separately .
Supply, installation testing and commissioning of outdoor type distribution transformer, level-2, converter duty type low losses as per ECBC (3star rating in) of Minimum 160 KVA, 0.433/11 KV, 3 phase, 50 HZ,ONAN cooled, Oil immersed, copper double wound, outdoor type, complete with first fill of oil and other standard fitting/ accessories and seven point off load ta changer (tapping range +/- 7.5% in steps of 2.5% each)with VECTOR GROUP Dyn-11 or as per inverter supplier recommendations as per IS 1180 2014 including HV Cable Box (Without Cable Glands) LV Cable Box (Without Cable Glands), Magnetic oil level gauge, Conservator with oil filling hole with cap and drain plug and wit built in Buchholz Relay with alarm and trip contact and shut off valves. Oil temperature indicator 150 mm dia with alarm and trip contact. Oil level indicator with minimum level marking. The mometer pockets with thermometer. Silica gel breather Air Release plug. Lifting Lugs Earthing terminals Bi-directional Rollers Anodized aluminum rating and diagram plate all as specified and directed. Note : .The transformer shall be erected on PCC platform .The PCC platform shall be measured and paid for separately .
M & L for Plain cement concrete in foundations filling and mass concrete Type C2 1:3:6 (40mm graded aggregate) for transformer staging/pole foundation all as directed.
Supply ,Fabricate, install, connect, test and commissioning Bus bar chamber, powder coated, outdoor weather proof type, compartmentalized fabricated with 3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium bus bars, separate compartment for switch gear, louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron/flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars complete all as specified and comprising of the followings:-(i) 4 Nos bus bar of equal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of 400 Amps mounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (ii) MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole, 36 kA.- 1 Nos. Note : MCCB shall be front handle operated. The cost of PCC pillars shall deem to have been included in quoted rate
Supply & Lay cable XLPE insulated screened PVC bedded, gaivanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor extruded PVC Type ST2 Outer sheathed, 650/1100V as per IS 7098(part-I) of 3.5 core 70 Sq mm all as specified and as directed.
Supply & Lay cable XLPE insulated screened PVC bedded, gaivanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor extruded PVC Type ST2 Outer sheathed, 650/1100V as per IS 7098(part-I) of 3.5 core 50 Sq MM all as specified and as directed.
Supply and laying galvanized iron tubing, light grade of size 100 mm bore in trench/road crossing/fixed on pole complete including all necessary fittings complete all as specified and as directed .
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5 m below normal ground level connected to GI earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers made out of GI and GI earth strip protected by 40 mm bore light grade GI pipe, watering arrangement by provision of 20mm dia GI pipe medium grade with cast iron funnel, provision of test point and connected to main control board all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1 : 2 : 4 type B - 1 in chamber and 40 mm thick RCC 1 : 2 : 4 type B - 1 cover slab with 6 mm dia mild steel bars at 100 mm centre to centre both ways with 6 mm dia M S hooks complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60xm x 60cm x6 mm thick buried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x6mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, charcoal and common salt filling, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meters, complete all as per plate No-3, SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion.
REPLACEMENT OF TWO POLE STRUCTURE Dismantling old unserviceable mild steel channel or angle sections etc from two pole structures-03 Nos and taken on credit complete all as specified and as directed. Note: Porcelain insulators,AB switches, DO fuse units and Lightning arrestors shall also be dismantled along with the conductors and taken on credit.
Dismantling old unserviceable PCC pole 11 M height of any description and taken on credit complete all as specified and as directed. Note: The cost of earth work excavtion,demolition of PCC foundation and coping and making good the disturbed portion with PCC lean concrete as directed shall be deemed included in quoted rate of contractor
Green Ray Technologies
EVEREST ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .