| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹11.4 L+₹59,210 (5.46%)Rejected-Finance NO 22 KUNNIJI NAGAR 1ST STREET EAST TAMBARAM CHENNAI 600 059 TAMIL NADU | CHENNAI | CHENNAI | TAMIL NADU | 600059 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹12.0 L+₹1.1 L (10.3%)Rejected-Finance OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹13.3 L+₹2.5 L (22.9%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹13.3 L+₹2.5 L (23.0%)Rejected-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L5 | Rejected-Finance BEING L5 |
Tender Value
₹12.6 L
EMD Value
₹25,260
Closing Date
9 Jan 2025, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI
PROVISION OF DEFICIENT GEYSERS CEILING FANS AND EXHAUST FANS IN TOILET BATHROOM OF OFFICERS MARRIED ACCOMODATION TYPE QUARTERS AT AVDI
2024_MES_688727_1
8665/E8
Open Tender
Civil Works
Item Rate
180 days
AVADI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹25,260
Yes
27 Jan 2025
14 Dec 2024
11 Jan 2025
14 Dec 2024
9 Jan 2025
26 Dec 2024
Amount
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. Concealed work, including cutting chases and making good the wall etc. (16 mm OD) pipe
All same as per item sl No- 1 above but for 20 mm OD pipe
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing C.P. brass angle valve 15 mm nominal bore for basin mixer and geyser points of approved quality confirming to IS:8931
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : suitable for 15 mm nominal bore.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. suitable for 15 mm nominal bore.
Wiring for light point/exhaust fan point/call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc as required. (For Ceiling Fans - 22 Nos & Exhaust Fans - 22 Nos) (a) Group A
Supplying and Fixing 3 pin 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver
Wiring for circuit/submain wiring with 2 X 4.0 Sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 X 4.0 Sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (for 22 Points)
Supply and Fixing 20 Amps, 230 V SPN industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 20 Amps "C" curve SP MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as required.
Supply and fix, testing and commissioning of electric water heater (Electric Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes etc. Make- Havells, Model No- MonzaNU or equivalent in Bajaj/Venus/Crompton Note:- Quoted rate is deemed to be inclussive of necessary fixing arrangements like anchor bolts, plates, Bolts & Nuts etc required at site complete.
Supplying and fixing 6 Way Double door, single pole and neutral, sheet steel, MCB distribution board 240 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (But with out MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single Pole and neutral (SPN) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single Pole (SP) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
M & L Earthing with GI Earth plate 600mm x 600 mm x 6mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc with charcoal/coke and salt as required.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe 15 mm or fixed to poles or any other indicated situation for loop earthing etc. as required 6 SWG dia, complete.
Sri Sankar Enterprises (BID ID -3210312)
NAVEEN ENTERPRIESES (BID ID -3202925)
EASHWAR ELECTRICALS (BID ID -3201241)
rc enterprises (BID ID -3209761)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .