| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹50.7 L+₹5.1 L (11.2%)Rejected-Finance NO 11 PONTHIYAGARAJAUDAYAR STREET THILLAIKANNAMAL NAGAR LAWSPET PUDUCHERRY 605008 | PONDICHERRY | PUDUCHERRY | 605008 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹51.0 L+₹5.3 L (11.7%)Rejected-Finance NO 2 RICE MILL STREET THIRUBHUVANAIPALAYAM PUDUCHERRY 605107 | PONDICHERRY | PUDUCHERRY | 605107 | L3 | Rejected-Finance Not Lowest |
Tender Value
₹48.6 L
EMD Value
₹97,125
Closing Date
18 Jan 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, BRN., PWD., Puducherry
No.44, Labourdonnais Street, Puducherry
Construction of RCC retaining wall at RC-4 Valudavour road at Ch.14/680 to 14/730 near MGR Nagar, Ossudu Constituency, Puducherry
2024_PWDC1_14670_1
60/PW/EE/BRN/2023-24
Open Tender
Civil Works - Buildings
Item Rate
90 days
Valudavour
Please refer tender document
3 documents required · 3 mandatory
₹525
₹97,125
21 Feb 2024
6 Jan 2024
19 Jan 2024
6 Jan 2024
18 Jan 2024
6 Jan 2024
Amount
Earthwork in excavation of foundation of structure as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remainging earth locally for road work - by mechanical means - depth upto 3m (Ordinary soil)
Supply of Quarry rubbish including stacking to department gauge for premeasurement and spreading required thickness
Cement concrete 1:4:8 mix with stone aggregate 40mm nominal size in foundation upto a depth of 1.5 metres below ground level and upto height of 1.5 above ground/bed level.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and sting courses, fillets, columns, pillars, piers, abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Centering and shuttering including strutting, propping etc and removal of form for - Walls (any thickness ) including attached pilasters, butteresses, plinth and string courses etc.
Steel reinforcement for R.C.C. Works including bending, binding and placing in position - Thermo Mechanical Treated Bars (ISI brand approved make) Fe - 415 or more
Providing and filling in foundation trenches and at the back of abutments, wing walls etc. and below pipe bed in layers not exceeding 150mm thick including watering and compacting including all lead and lifts. - Filter media behind abutment wing and return wall.
Providing and fixing prmoulded bitumen joint filler, for expansion joints including the cost of sealing compound and priming coat - 25 mm wide.
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces.
Providing and fixing 110 mm dia PVC pipes (4kg / cm2) in weep holes including cement concrete 1:5:10 (one cement : 5 sand : 10 graded stone aggregate ) and filling of pebbles etc.,
Supplying and placing in position HDPE cement bags filled with sand for breach closing / diversion arrangement. The cost includes the cost of empty HDPE bags, labour charges for filling the bags and placing in position , removing the bags from site after completing the work etc., complete
Supplying and filling with gravel (excluding rock) in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or steel rammers, including all leads and lift etc., complete for making play fields, running trees and court yards
Close timbering over areas including strutting, shoring and packing cavities (whwerever required ) etc. Complete (measurements to be taken of the face area timbered) . Depth exceeding 3m but not exceeding 4.5m
R KESAVARAMAN
R SELVAKANNAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .