Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC CHAWK BAZAR MOGOL PURA LANE PO DIST HOOGHLY | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | ₹27.5 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹27.5 LRejected-Finance MOGALPURA LANE CHAWKBAZAR HOOGHLY PIN 712103 | HOOGHLY | WEST BENGAL | 712103 | ₹27.5 L | L2 | Rejected-Finance Higher rate received. |
| 3 | L2₹27.5 LRejected-Finance NA | NA | NA | 121004 | ₹27.5 L | L2 | Rejected-Finance Higher rate received |
Tender Value
₹26.7 L
EMD Value
₹53,381
Closing Date
27 Jan 2026, 4:00 pmClosed
Executive Engineer, Hooghly Highway Division No. I
Executive Engineer, Hooghly Highway Division No. I, P.W. (Roads) Directorate, Vivekananda Road, Pipulpati, Hooghly
Construction RCC drain with cover slab for Improvement of rain water drainage of Kapastikuri Meria Road (ODR) chainage from 2.70 km to 2.90 km during the year 2025-26. (Under SDMF) (2nd Call)
2026_WBPWD_983619_1
WBPWD/EE/HHD-I/NIT-11/2025-26
Open Tender
CIVIL WORKS
60 days
Hooghly
Please refer Tender documents.
5 documents required · 5 mandatory
₹53,381
Yes
2 Mar 2026
5 Jan 2026
29 Jan 2026
9 Jan 2026
27 Jan 2026
10 Jan 2026
RCC Drain
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 for Rural Roads of MORD including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Sand filling in foundation trenches and at the back of abutments, wing-walls etc. with good local sand free from earth in layers not exceeding 15 cm. including inundating each layer by profuse water and poking and ramming layer by layer complete including supply of sand. Quality of sand is to be approved by the Engineer-in-charge.
Providing and laying Design Mix concrete concrete work in any part of bridge with coarse Pakur aggregates of appropriate nominal size and grading, fine aggregate (Coarse sand) conforming to proper grading zone, both of approved quality and cement, as necessary, including labour, cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge and cost for quality control, sampling, testing etc. PCC M-15 Grade Using concrete mixer.
Plain / Reinforced Cement Concrete in Open foundation with or without reinforcements, in any part of foundation of bridges / culverts with graded stone chips of appropriate nominal sizes, including screening and cleaning of coarse aggregates, fine aggregate (sand) conforming to proper grading zone, both of approved quality and cement, as necessary, cost of curing with water, including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control, sampling, testing etc. including cost of formwork but excluding reinforcement complete as per drawing and technical specifications. Using 43 grade Cement @ 400 Kg/m3 D RCC Grade M25 Height upto 5 m. I) Using concrete mixer
Supplying, fitting and placing un-coated HYSD bar (SAIL/TATA/RINL) reinforcement in Bridge Foundation including initial straightening, straightening of coils bars, removal of loose rust (if any), cutting to requisite length bending, binding with annealed wire not less than 1 mm in size and conforming to IS 280 at every intersection hooked and bent to correct shape and placed on forms etc. including cost of black annealed wire and cost of loading, unloading, carriage of all steel materials complete as per drawing and technical specifications and direction of Engineer-in-charge. TATA/SAIL/RINL
Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
Supplying & fixing of Raised Pavement Markers / Road Studs / Cats Eye made of polycarbonate moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face which shall support a load of 13635 kg tested in accordance to ASTM D 4280 Type H and complying to clause no 804 of MoRT&H's specification for Road &Bridge Works (Fifth Rev.). Marker height shall not be less than 10 mm and shall not exceed 20 mm, width shall not exceed 130mm and with minimum reflective area of 13 sq.cm. on each side and slope to the base shall be 35 ± 5 degree. Fixing will be without nails but by using epoxy resin based adhesive as per manufacturer's recommendation including site clearance etc. and complete as directed by the Engineer in Charge .The contractor will have to provide a test certificate from a reputable national/international laboratory conforming the above specifications.
Add GST @ 18%
Add Labour Welfare Cess @ 1%
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.70 MB
Government_Orders_merged.pdf
Tender Documents • 4.37 MB
BOQ_2400010.xls
BOQ • 0.30 MB
2911_Form.pdf
Tender Documents • 0.54 MB
Download all tender documents and submit your bid