Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.9 L+₹1,302 (0.08%)Rejected-Finance BYE PASS DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹17.2 L+₹1.3 L (8.06%)Rejected-Finance 73 5 NANAK NAGAR JAMMU 180004 J K | JAMMU | JAMMU | J K | 180004 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹17.8 L+₹1.9 L (11.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹17.9 L+₹2.0 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Hi Tech Engineers L1 | Allied Technologies L3 | ASHOKKUMAR SURI L5 | M/S GULATI ENGINEERING WORKS L2 | M/S VIDYA ENTERPRISES L4 | ARORA ENTERPRISES L6 | Warne Builders L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Note :- 1. The work is meant for day to day maintenance based on complaints . The complaints are required to be attended / cleared on the same day of the reporting. However in exceptional case, if any complaint could not be attended on the same day,the same will be cleared within 48 hours of the reporting. If contractor fails to attend / clear the complaint within 48 hours, a penalty of Rs. 950/- per complaint per day will be imposed till the completion of complaint and recovery amount will be deducted from the RAR submitted by contractor.The T&P required shall be arranged by the contractor. 2. The contractor shall be provided with space for setting up maintenance cell at the specified location as per the directions of Engineer-in-Charge.The maintenance cell shall be manned by the contractor's supervisor responsible for collecting complaints from the concerned JE/AGE. A proper record of complaints will be maintained by the concerned JE duly signed by contractor. 3. The contractor shall employee minimum one skilled labour having experience of the trade with helper daily to attend the complaint. | ||||||||||
| 2.00 | M&L for servicing/cleaning of indoor and out door unit of split Type air conditioner / window type AC of capacity 2.0 TR by adding cleaning solution with water. The cleaning of the condensor and chiller tubes is to be done using nylon brushes untill the scaling is fully removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition complete all as specified and directed .
Note :- Replacement of spare parts will be measured and paid separately under relevant item of BoQ'. | 15 | Each Job | 500 ₹7,500 | 50 ₹750 Lowest | 300 ₹4,500 | 444 ₹6,660 | 200 ₹3,000 | 150 ₹2,250 | 250 ₹3,750 |
| 3.00 | All as per Ser item No 02 here-in-before but split type AC of capacity 1.5 TR | 70 | Each Job | 500 ₹35,000 | 50 ₹3,500 Lowest | 230 ₹16,100 | 444 ₹31,080 | 130 ₹9,100 | 150 ₹10,500 | 200 ₹14,000 |
| 4.00 | All as per Ser item No 02 here-in-before but window type AC of capacity 2 TR | 30 | Each Job | 500 ₹15,000 | 10 ₹300 Lowest | 200 ₹6,000 | 444 ₹13,320 | 100 ₹3,000 | 150 ₹4,500 | 200 ₹6,000 |
| 5.00 | M&L for servicing / cleaning of water cooler of any size and capacity by cleaning the outer unit by adding cleaning solution with water. The cleaning of condensor and chiller tubes is to be done using nylon brushes untill the scaling is fully removed from water cooler .The inner tank should be cleaned using bleaching powder and keeping the inner tank clean from bacterial , descaling and ensuring its serviceability complete all as specified and directed .
Note :- Replacement of spare parts will be measured and paid separately under relevant item of BoQ'. | 30 | Each Job | 250 ₹7,500 | 20 ₹600 Lowest | 50 ₹1,500 | 444 ₹13,320 | 50 ₹1,500 | 50 ₹1,500 | 200 ₹6,000 |
| 6.00 | M&L for servicing / cleaning of refrigerator of any size and capacity by cleaning the outer unit by adding cleaning solution with water. The cleaning of condensor and chiller tubes is to be done using nylon brushes untill the scaling is fully removed .The inner surfaces should be cleaned using bleaching powder and keeping the inner tank clean from bacterial , descaling and ensuring its serviceability complete all as specified and directed .
Note :- Replacement of spare parts will be measured and paid separately under relevant item of BoQ'. | 30 | Each Job | 250 ₹7,500 | 20 ₹600 Lowest | 50 ₹1,500 | 444 ₹13,320 | 50 ₹1,500 | 45 ₹1,350 | 200 ₹6,000 |
| 7.00 | M&L for servicing / cleaning of deep freezer of any size and capacity by cleaning the outer unit by adding cleaning solution with water. The cleaning of condensor and chiller tubes is to be done using nylon brushes untill the scaling is fully removed from deep freezer.The inner tank should be cleaned using bleaching powder and keeping the inner tank clean from bacterial , descaling and ensuring its serviceability complete all as specified and directed .
Note :- Replacement of spare parts will be measured and paid separately under relevant item of BoQ'. | 5 | Each Job | 300 ₹1,500 | 20 ₹100 Lowest | 50 ₹250 | 444 ₹2,220 | 50 ₹250 | 45 ₹225 | 200 ₹1,000 |
| 8.00 | Taking out unserviceable Receprocating type compressor of window type AC, 1.5/2.0 Ton capacity and S&F new Receprocating type compressor sealed unit of existing make in position, charging of refrigerant gas R-22 /R-32/R410a of required quantity, bracing of discharge & suction line and leak testing complete all as specified and directed . | 5 | Each Job | 6,000 ₹30,000 | 6,000 ₹30,000 | 9,000 ₹45,000 | 7,000 ₹35,000 | 5,000 ₹25,000 Lowest | 6,400 ₹32,000 | 8,000 ₹40,000 |
| 9.00 | All as per Ser item No 8 here-in-before but of split type AC of capacity 1.5 Ton | 20 | Each Job | 6,000 ₹1,20,000 | 6,000 ₹1,20,000 | 6,500 ₹1,30,000 | 7,000 ₹1,40,000 | 4,500 ₹90,000 Lowest | 6,400 ₹1,28,000 | 6,500 ₹1,30,000 |
| 10.00 | All as per Ser item No 8 here-in-before but of split type AC of capacity 2.0 Ton | 5 | Each Job | 7,500 ₹37,500 | 6,000 ₹30,000 | 8,500 ₹42,500 | 7,000 ₹35,000 | 5,000 ₹25,000 Lowest | 7,400 ₹37,000 | 8,000 ₹40,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SATWARI
GE SATWARI
REPAIR/MAINT OF SUMMER COOLING AND HEATING APPLIANCES AT MH AND RAIPUR SATWARI UNDER AGE E/M OF GE SATWARI
2025_MES_723980_1
GEJM-41/2025-26
Open Tender
Electrical and Maintenance Works
Works
270 days
GE SATWARI
Class D cat b(i)
9 documents required · 9 mandatory
₹500
GE SATWARI
₹60,000
Yes
30 Sept 2025
1 Aug 2025
25 Aug 2025
1 Aug 2025
23 Aug 2025
16 Aug 2025
Amount
Note :- 1. The work is meant for day to day maintenance based on complaints . The complaints are required to be attended / cleared on the same day of the reporting. However in exceptional case, if any complaint could not be attended on the same day,the same will be cleared within 48 hours of the reporting. If contractor fails to attend / clear the complaint within 48 hours, a penalty of Rs. 950/- per complaint per day will be imposed till the completion of complaint and recovery amount will be deducted from the RAR submitted by contractor.The T&P required shall be arranged by the contractor. 2. The contractor shall be provided with space for setting up maintenance cell at the specified location as per the directions of Engineer-in-Charge.The maintenance cell shall be manned by the contractor's supervisor responsible for collecting complaints from the concerned JE/AGE. A proper record of complaints will be maintained by the concerned JE duly signed by contractor. 3. The contractor shall employee minimum one skilled labour having experience of the trade with helper daily to attend the complaint.
M&L for servicing/cleaning of indoor and out door unit of split Type air conditioner / window type AC of capacity 2.0 TR by adding cleaning solution with water. The cleaning of the condensor and chiller tubes is to be done using nylon brushes untill the scaling is fully removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition complete all as specified and directed . Note :- Replacement of spare parts will be measured and paid separately under relevant item of BoQ'.
All as per Ser item No 02 here-in-before but split type AC of capacity 1.5 TR
All as per Ser item No 02 here-in-before but window type AC of capacity 2 TR
M&L for servicing / cleaning of water cooler of any size and capacity by cleaning the outer unit by adding cleaning solution with water. The cleaning of condensor and chiller tubes is to be done using nylon brushes untill the scaling is fully removed from water cooler .The inner tank should be cleaned using bleaching powder and keeping the inner tank clean from bacterial , descaling and ensuring its serviceability complete all as specified and directed . Note :- Replacement of spare parts will be measured and paid separately under relevant item of BoQ'.
M&L for servicing / cleaning of refrigerator of any size and capacity by cleaning the outer unit by adding cleaning solution with water. The cleaning of condensor and chiller tubes is to be done using nylon brushes untill the scaling is fully removed .The inner surfaces should be cleaned using bleaching powder and keeping the inner tank clean from bacterial , descaling and ensuring its serviceability complete all as specified and directed . Note :- Replacement of spare parts will be measured and paid separately under relevant item of BoQ'.
M&L for servicing / cleaning of deep freezer of any size and capacity by cleaning the outer unit by adding cleaning solution with water. The cleaning of condensor and chiller tubes is to be done using nylon brushes untill the scaling is fully removed from deep freezer.The inner tank should be cleaned using bleaching powder and keeping the inner tank clean from bacterial , descaling and ensuring its serviceability complete all as specified and directed . Note :- Replacement of spare parts will be measured and paid separately under relevant item of BoQ'.
Taking out unserviceable Receprocating type compressor of window type AC, 1.5/2.0 Ton capacity and S&F new Receprocating type compressor sealed unit of existing make in position, charging of refrigerant gas R-22 /R-32/R410a of required quantity, bracing of discharge & suction line and leak testing complete all as specified and directed .
All as per Ser item No 8 here-in-before but of split type AC of capacity 1.5 Ton
All as per Ser item No 8 here-in-before but of split type AC of capacity 2.0 Ton
Taking out unserviceable Rotary type compressor of window type AC, 1.5 /2.0 Ton capacity and S&F new Rotary type compressor sealed unit in position, charging of refrigerant gas R-22 of required quantity, bracing of discharge & suction line and leak testing complete all as specified and directed .
All as per Ser item No 11 here-in-before but of split type AC of capacity 1.5 Ton
All as per Ser item No 11 here-in-before but of split type AC of capacity 2.0 Ton
Pressue testing/ leak arresting, vaccumising with dry nitrogen gas/ oil charging, including replacing the unserviceable strainers and capillary tubes (as required ) and testing complete for air condtioner (any type) of capacity 1.5/ 2TR complete all as specified and directed . Note :-(i) Charging of gas of any type shall be measured and paid separately under relevant item of BoQ. (ii) The quoted rates shall be deemed to be included the transportation charges to & from workshop, if required
All as per Ser item No 14 here-in-before but for water cooler of any make and capacity
All as per Ser item No 14 here-in-before but for refrigerator of any make and capacity
All as per Ser item No 14 here-in-before but for deep freezer of any make and capacity.
M&L for gas charging with R-134a/410/22A in refrigerator and water coolers in position including leak testing to achieve desired suction pressure and temperature complete all as specified and directed.
M&L for gas charging with R-32 in split / windows type AC in position including leak testing to achieve desired suction pressure and temperature complete all as specified and directed.
S&F in replacement of condenser blower motor as per existing of outdoor unit of split AC /Window type AC 1.5/2 TR capacity complete all as specified and directed.
S&F in replacement of condenser blower motor as per existing of water cooler / deep freezer/ refgrigerator of any capacity, make and model complete all as specified and directed.
S&F in replacement of blower motor as per existing of indoor unit of split AC 1.5/ 2TR complete all as specified and directed.
S&F in replacement of fan blade as per existing of split / window type Air conditioner of capacity 1.5 / 2 Ton complete all as specified and directed .
S&F in replacement of fan blade as per existing of water cooler of any capacity / make complete all as specified and directed .
S&F in replacement of thermostat of water cooler / refrigerator / deep freezer / window type AC of any capacity & make complete all as specified and directed.
S&F in replacement of relay as per existing of AC / water cooler /refrigerator/deep freezer of any capacity & make complete all as specified and directed.
S&F in replacement of overload protector as per existing of AC/water cooler / refrigerator/ deep freezer of any capacity & make complete all as specified and directed .
S&F in replacement of PCB as per existing suitable for split type AC., 2.0/1.5 TR of any make complete all as specified and directed .
S&F in replacement of PCB card of inverter technology split AC, 1.5/2.0 TR of any make complete all as specified and directed.
M&L for repairing defective PCB card of inverter technology split AC, 1.5/2.0 TR of any make complete all as specified and directed .
M&L for repairing defective PCB of window/split type AC, 1.5/2.0 Ton, any make complete all as specified and directed
S&F in replacement of wiring kit as per existing for split type AC, 2.0/1.5 TR of any make complete all as specified and directed.
S&F in replacement of wiring kit as per existing for water cooler/ refrigerator / deep freezer /window type AC of any capacity & make complete all as specified and directed.
S&F in replacement of starting capacitor, 80/100 mfd for AC, any capacity & make complete all as specified and directed.
S&F in replacement of starting capacitor, 120 mfd for AC, any capacity & make complete all as specified and directed.
S&F in replacement of running capacitor, 45 mfd for AC,1.5 TR complete all as specified and directed.
S&F in replacement of running capacitor, 60 mfd for AC, 2.0 TR complete all as specified and directed.
S&F in replacement of running capacitor, 36 mfd for AC & water cooler of any capacity & make complete all as specified and directed.
S&F in replacement of auto swing motor as per existing for inside unit of split AC of capacity 2.0/1.5 TR of any make complete all as specified and directed.
S&F in replacement of PCB suitable for remote control system of split / window type AC of capacity 2.0/1.5TR complete all as specified and directed.
S&F in replacement of PVC air filter as per existing for split /window type AC of any capacity & make complete all as specified and directed.
S&F in replacement of contactor as per existing for AC of capacity 2.0/1.5 TR of any make complete all as specified and directed.
S&F in replacement of front grill as per existing for 1.5/2.0 TR window type AC of any make/model complete all as specified and directed.
S&F in replacement of display unit as per existing of AC, any type , make & model complete all as specified and directed.
S&F in replacement of reversible valve in window/split AC, 1.5/2.0 TR including making bypass system with copper tubes/brazing works etc complete all as specified and directed.
S&F in replacement of outdoor unit of split Air conditioner of cap 1.5 TR ,Hot & Cold type with all accessories as per existing make and model complete all as specified and directed.
S&F in replacement of motor,three speed, single phase , double shaft of existing rating/make & type suitable for window type AC, 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of motor,single speed, single phase of existing rating/make & type suitable for condensing unit (outer unit ) of split type AC, 1.5/2.0 Ton complete all as specified and directed.
S&F in replacement of motor,three speed, single phase of existing rating/make & type suitable for cooling unit (inner unit) of split type AC, 1.5/2.0 Ton complete all as specified and directed.
S&F in replacement of brass angle valve, 5/8 inch as per existing for split AC 1.5/2.0 TR capacity complete all as specified and directed.
S&F in replacement of brass angle valve, 3/8 inch as per existing for split AC 1.5/2.0 TR capacity complete all as specified and directed.
S&F in replacement of copper tubing 5/8" dia for extending refrigerant piping including brazing/adopter and accessories complete all as specified and directed.
S&F in replacement of copper tubing 3/8" dia for extending refrigerant piping including brazing/adopter and accessories complete all as specified and directed.
S&F in replacement of Puff insulation to suction pipe of split AC complete all as specified and directed
S&F in replacement of door lock as per existing for refrigerator /deep freezers of any capacity & make complete all as specified and directed.
S&F in replacement of baffle tray as per existing for refrigerator of any type/model complete all as specified and directed.
S&F in replacement of crisper tray as per existing for refrigerator of any type/model complete all as specified and directed.
S&F in replacement of Bi-metal as per existing for refrigerator of any type/model complete all as specified and directed.
S&F in replacement of de-frost timer as per existing for refrigerator of any type/model complete all as specified and directed.
S&F in replacement of PVC ball valve/ PVC float valve as per existing for water cooler of any capacity & make complete all as specified and directed.
S&F in replacement of brass chromimum plated push button tap of size 15 mm for water cooler of any capacity & make complete all as specified and directed.
S&F in replacement of drain pipe as per existing size for water cooler complete all as specified and directed.
S&F in replacement of PCB suitable for voltage stabilizer of capacity upto 5 KVA complete all as specified and directed.
S&F in replacement of transformer suitable for voltage stabilizer of capacity 4 KVA to 5 KVA complete all as specified and directed.
M&L for plug top,3 pin 15 Amp complete all as specified and directed
M&L for plug top,3 pin 5 Amp complete all as specified and directed
S&F in replacement of indoor type unit as per existing of split Air conditioner of cap 1.5 TR , Hot & Cold type with all accessories complete all as specified and directed
S&F in replacement of sheet metal enclosure with socket plug top and MCBs SPN 20 Amp, 240 V, AC Supply, single pole enclosure with a two pin and earth plug with socket complete all as specified and directed
S&F mild steel clamps, bracket, supports, bolts, nuts & washers for stand/supporting window/split AC & desert cooler including necessary fixing on wall and making good to match with surrounding as per existing complete all as specified and directed.
Taking down existing window / split type AC of any make / capacity after disconnecting all connects and Refixing in same / another location including fixing arrangement, after carrying out necessary maintenance / servicing including testing on load at site complete all as specified and directed .
S&F in replacement of fan motor with blade for desert cooler,180 watt, heavy duty, 220/240Volts, 50 Hz, single phase and testing complete all as specified and directed..
S&F in replacement of submersible pump 50 watts for desert cooler, operational on 230 volts AC, 50 Hz complete all as specified and directed.
S&F in replacement of capacitor 3.15 to 4 MFD complete all as specified and directed.
S&F in replacement of indication lamp 230 volts, 50 Hz for desert cooler complete all as specified and directed.
S&F in replacement of PVC water connection pipe including PVC elbow & stop cock as per existing size complete all as specified and directed..
S&F in repair float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of bore 20mm including necessary fittings (Min weight 210gm) complete all as specified and directed.
S&F in replacement of Wood wool pad set,superior quality for desert cooler of any type complete all as specified and directed.
S&F in replacement of PVC water distribution pipe including PVC elbow /Tee for distributor as per existing suitable for desert cooler complete all as specified and directed .
M&L for servicing/cleaning of indoor and outdoor unit of walk in cooler (cold store) by adding cleaning solution with water and ensuring its serviceability by rectification/ replacement of unserviceable parts like Gas charging, fans and keeping cold store in good working condition complete all as specified and directed .
Taking down of Geyser of capacity 25 / 50 Ltr, any type, make and re-fixing the same in same location / other location by mounting on wall including provision of 4 no of anchor bolts of suitable size, PVC connection for inlet connection and cromium plated copper connection for outlet (hot water), making electric connections & testing complete all as specified and directed .
M&L for servicing , cleaning with caustic soda solution including trouble shooting / rectifying leakage by braising assembly of geyser 25 Ltrs to 50Ltrs capacity, checking the serviceability of individual parts such as thermostat, heating element, pressure release valve, inlet/outlet connections etc, replacing worn-out nuts bolts, washers, fasteners and defective components and testing including taking down the geysers and refixing the same after repairs complete all as specified and directed. Note : Replacement of spare parts will be measured and paid separately under relevant item of BoQ'.
S&F in replacement of copper heating coil 1.5 KW of any type (Circular, spring single/double rounded, tringle single/double) of geyser complete all as specified and directed .
S&F in replacement of copper heating coil 2.0 KW of any type (Circular, spring single/double rounded, tringle single/double) of geyser complete all as specified and directed .
S&F in replacement of copper heating coil in built of thermostate 1.5 /2.0 KW of any type i.e Circular, spring single/double rounded, tringle single/double of geyser complete all as specified and directed .
S&F in replacement of thermostat for geyser of any capacity complete all as specified and directed . .
S&F in replacement of copper assembly of size not less than 15mm bore (water inlet & outlet) of any type /make of geyser of cap 50 Ltrs complete all as specified and directed.
All as per ser item No 88 here-in-before but geyser of cap 25 Ltrs
S&F in replacement of glass lined double ceramic element 2 KW with two years guarantee all as per existing make / model / size complete all as specified and directed .
S&F in replacement of drain plug including rubber washer etc suitable for storage type water heater of capacity 25/50 litres complete all as specified and directed . .
S&F in replacement of pressure release valve 15mm dia for geyser of any type / make/capacity complete all as specified and directed .
S&F in replacement of heavy duty PVC flexible steel wire laminated connection pipe 15mm dia, 450mm long with check nuts suitable for cold/hot water connection of geysers complete all as specified and directed . .
S&F in replacement of heavy duty PVC flexible steel wire laminated connection pipe 15mm dia, 600mm long with check nuts suitable for cold/hot water connection of geysers complete all as specified and directed . .
S&F in replacement of PVC insulated copper flexible cable of size 4 sq mm, 3 core complete all as specified and directed . .
S&F in replacement of metal plug top 15 Amps, industrial type complete all as specified and directed .
S&F in replacement of anchor bolt/fastner of size 4" for fixing of geyser of any type complete all as specified and directed.
M&L in repair steel water tubing of 15 mm bore, medium grade, galvanised, with all fittings, laid in trenches/ fixed to wall etc complete all as specified and directed .
S&F in repair Stop valve, cast copper alloy, screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed.
S&F in replacement cast copper alloy non return valve, 20 mm dia suitable for geyser of any make/capacity complete all as specified and directed.
Taking down the copper or steel container carefully from the geyser, descaling, rectifying leakage by braising, resetting the insulation (glass wool), testing for the required pressure, replacing rubber gaskets, worn-out fasteners etc, with new ones complete all as specified and directed
S&F in replacement of MCB 6 to 32 Amps ,single pole, 240 volts, 10 KA rupturing capacity complete all as specified and directed.
S&F in replacement of base plate of geyser of 25 / 50 Ltrs capacity complete all as specified and directed.
S&F in replacement of Indicator Lamp (Red / Green) suitable for geyser complete all as specified and directed
S&F in replacement of stainless steel body of water storage inner tank , porcelain enameled, glass lined ( with five years guarantee), pressure minimum 8 bar of capacity 25 Ltrs including 15mm dia galvanised air release valve complete all as specified and directed
S&F in replacement of stainless steel body of water storage inner tank , porcelain enameled, glass lined (with five years guarantee), pressure minimum 8 bar of capacity 50 Ltrs including 15mm dia galvanised air release valve complete all as specified and directed.
S&F in replacement of stainless steel body of water storage inner tank of capacity 25 Ltrs including 15mm dia galvanised air release valve complete all as specified and directed
S&F in replacement of stainless steel body of water storage inner tank of capacity 50 Ltrs including 15mm dia galvanised air release valve complete all as specified and directed
S&F in replacement of thermal cut out (Bi-metallic disc type) with snap action switch, with operator below the boiling point i.e 90º+ 6ºC with manual reset-knob for geyser. complete all as specified and directed
S&F in replacement of glass wool suitable for geyser of any capacity complete all as specified and directed
S&F in replacement submain wiring with two runs of single core PVC FRLSH unsheathed, insulated, copper cable of 04 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLSH copper wire 04 Sqmm for continous earth wire drawn into and including concealed PVC rigid conduit of suitable size including cutting chases in wall and making good all disturbed surfaces matching with existing surfaces complete all as specified and directed. Note :-Two runs of 04 Sqmm copper cable and one run of 04 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F in replacement of heating element 2.0 KW in built in assembly as per existing make and model including connection complete all as specified and directed
S&F in replacement of heating element 1.5 KW in built in assembly as per existing make and model including connection complete all as specified and directed
S&F in replacement of sheet metal enclosure with socket plug top and MCBs SP 20 Amp, 240 V, AC Supply, single pole enclosure with a two pin and earth plug with socket complete all as specified and directed
M/S GULATI ENGINEERING WORKS (BID ID -3403995)
Allied Technologies (BID ID -3404067)
M/S VIDYA ENTERPRISES (BID ID -3403650)
ASHOKKUMAR SURI (BID ID -3404229)
ARORA ENTERPRISES (BID ID -3404312)
Warne Builders (BID ID -3403545)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .