Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹16.1 L+₹6.1 L (61.3%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L2 | Rejected-Finance Other than lowest bid | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Jan 2020, 6:00 pmClosed
Garrison Engineer (West) Jalandhar Cantt
Garrison Engineer (West) Jalandhar Cantt
As described in Bill of quantities
2019_MES_308343_1
GE/JAL(W)-66/2019-20
Open Tender
Civil Works
Item Rate
334 days
Jalandhar Cantt
As per Tender Documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (West) Jalandhar Cantt
₹30,000
Yes
19 Feb 2020
21 Dec 2019
18 Jan 2020
21 Dec 2019
16 Jan 2020
4 Jan 2020
Amount
Outsourcing of services for operation, maintenance documentation, and control including periodical maintenance of package type air conditioning plant 17.50 TR (2x8.75 TR), 01 No x 8.75 TR as standby and including maintenance, operation, documentation and control including periodical and preventive maintenance of DG set three phase 415 volts of capacity 1x160 KVA (AMF) installed at 11 CSR Signal Centre for three shifts of 8 hrs each shift per day by providing operator (ITI Electrical/Fitter/Diesel Mech) with minimum two years experience resposnsible for plant operation (One operator in each shift of 8 hrs) (A) AC Plant (i) Package type air conditioning unit Make Voltas capacity 8.75 TR-03 Nos (ii) Outdoor condensing units Make Voltas- 03 Nos (iii) Electric panel for AC Plants- 01 No (iv) Wiring and inter locking wiring for AC plant - 01 Set (v) Control system complete - 01 Set (vi) Winter heating system complete-01 Set (vii) Water circulating system with GI pipe and Gun metal gate valve - 01 Set (B) DG Set (i) DG set alongwith panel AMF mode of 160 KVA- 01 No (ii) LT panel incoming and outgoing - 02 Nos (iii) Voltage stabilizer servo controlled 415 volts of capacity 75 KVA- 01 No (iv) Voltage stabilizer servo controlled 415 volts of capacity 160 KVA- 01 No (v) Battery 12 volts 180 AH- 04 Nos (vi) Battery charger 12 Volt- 01 No (vii) Manual operated rotary pump for diesel - 01 No
Outsourcing of services for operation, maintenance documentation, and control including periodical maintenance of package type air conditioning plant 8.75 TR (1x8.75 TR), 01 No x 8.75 TR as standby and including Maintenance, Operation, Documentation and control including periodical and preventive maintenance of DG set three phase 415 volts of capacity 1x40 KVA AMF installed at AD Regt for three shifts of 8hrs each shift per day by providing operator (ITI Electrical/Fitter/Diesel Mech) with minimum two years experience resposnsible for plant operation (One operator in each shift of 8 hrs) (A) AC Plant (i) Package type air conditioning unit Make Voltas capacity 8.75 TR-02 Nos (ii) Outdoor condensing units Make Voltas - 02 Nos (iii) Electric panel for AC Plants - 01 No (iv) Wiring and interlocking wiring for AC plant - 01 Set (v) Control system complete- 01 Set (vi) Winter heating system complete-01 Set (vii) Water circulating system with GI pipe and Gun metal gate valve- 01 Set (B) DG Set . (i) DG Set along with AMF panel manually operated of 1x40 KVA - 01 No (ii) LT panel incoming and outgoing - 01 No (iii) Battery 12 volts 180 AH - 01 No (iv) Battery charger 12 Volts - 01 No (v) Manual operated rotary pump for diesel -01 No
Outsourcing of services for operation, maintenance documentation, and control including periodical maintenance of central air conditioning plant DX type of capacity 16 TR (1x16 TR) -01 No. 16 TR as standby installed at 987 AD Regt workshop for one shift of 8hrs per day by providing operator (ITI Electrical/Fitter/Diesel Mech) with minimum two years experience resposnsible for plant operation (One operator in each shift of 8 hrs) (a) Compressor of Make Accel model SMC -6-65 capacity 16 TR - 02 Nos (b) Shell and tube type condenser 16 TR-02 Nos (c) Electric driven motor 25 HP for compressor - 02 Nos (d) Mono block pump set 5 HP for condenser - 02 Nos (e) AHU with electric driven motor 7.5 HP- 1 No (f) Cooling tower FRP with Axial fan - 01 No (g) Water softening plant- 01 No (h) Make up water tank 4000 Ltrs capacity - 01 No (i) Electrical panel for AC plant - 01. No (j) Wiring and interlocking wiring for AC plant - 01 Set (k) Control system complete - 01 Set (I) Suction and Liquid line - 01 Set (m) Winter heating system complete - 01 Set (n ) Water circulating system with GI pipe and GM gate valve - 01 Set
Outsourcing of services for Operation, maintenance documentation, and control including periodical maintenance of Central Air Conditioning plant DX type of capacity 26 TR (3x13 TR) installed at 661 R&O Sqdn for one shift of 8hrs per day by providing operator (ITI Electrical/Fitter/Diesel Mech) with minimum two years experience resposnsible for plant operation (One operator in each shift of 8 hrs) (a) Compressor Of Make Accel model SMC -4-65 capacity 13 TR - 03 Nos (b) Shell and tube type condenser 13 TR-02 Nos (c) Electric driven motor 20 HP for compressor - 02 Nos (d) Mono block pump set 3 HP for condenser - 02 Nos (e) AHU with electric driven motor 7.5 HP- 1 No (f) Cooling tower FRP with Axial fan - 01 No (g) Water softening plant- 01 No (h) Make up water tank 4000 Ltrs capacity - 01 No (i) Electrical panel for AC plant - 01 No (j) Wiring and inter locking wiring for AC plant - 01 Set (k) Control system complete - 01 Set (I) Winter heating system complete- 01 Set
Outsourcing of services for operation, maintenance documentation.and control including periodical maintenance of package type Air Conditioning plant 11 TR x 1 (11 TR x 1 as standby) and including maintenance operation, documenation and control including periodical maintenance of DG set three phase 415 volts of capacity 1x62.5 KVA (AMF) installed at RT road WEU for three shifts of 8hrs each shift per day by providing operator (ITI Electrical/ Fitter/ Diesel Mech) with minimum two years experience resposnsible for plant operation (One operator in each shift of 8 hrs) (A) AC Plant (i) Package type air conditioning unit Make Voltas capacity 11 TR-02 Nos (ii) Outdoor condensing units Make Voltas — 02 Nos (iii) Electric panel for AC Plants — 01 No (iv) Wiring and inter locking wiring for AC plant - 01 Set (v) Control system complete - 01 Set (vi) Winter heating system complete-01 Set (vii) Water circulating system with GI pipe and Gun metal gate valve - 01 Set (B) DG Set (i) DG Set along with panel manually operated of 62.5 KVA — 01 No (ii). LT panel incoming and outgoing - 01 No (iii) Battery 12 volts 180 AH - 02 Nos (iv) Battery charger 12 Volts -01 No (v) Manual operated rotary pump for diesel -01 No
CHOUDHARY AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .