Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-Finance RZ 14D 2ND FLOOR GALI NO 5 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹2.7 L+₹2,390 (0.89%)Rejected-Finance WZ 109 PLOT NO 327 CHAND NAGAR NEW DELHI | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹2.8 L+₹5,500 (2.04%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹2.8 L+₹10,900 (4.04%)Rejected-Finance WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than Lowest bidder |
Tender Value
Refer Docs
Closing Date
12 May 2025, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
PROVISION OF 02 INDUSTRIAL DESERT COOLERS FOR 202 CEDU UNDER GE U P M DELHI CANTT
2025_MES_706622_1
GE(U)/PM/3011/B/JO/19/E3
Limited
Miscellaneous Works
Piece-work
30 days
Delhi Cantt
PLEASE REFER NOTICE INVITING QUOTATION
1 document required · 1 mandatory
₹0
Exempted
16 May 2025
3 May 2025
14 May 2025
3 May 2025
12 May 2025
3 May 2025
Amount
M&L for Supply, Fabrication, Installation, Balancing and Commissioning of Site fabricated GSS sheet metal rectangular ducting with supports as per IS 655-2010 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers supports & mounting ,connecting unit to duct ,controller fixation ,joint gasket , nut bolts ,flanges ,cleats etc. of 24 gauges complete all as specified and directed by engineer in charge. - 85 Supply & Fixing of Air grills of size 100mm X600mm (imported Air Grills) with auto swing & rust free for life, specially engineered grill for longer airflow & wider angle coverage and upto 50% less sound icluding nuts, bolts, screws ,rubber gasket etc. to make the system complete all as specified and directed by engineer in charge- 10 SQM. Supply, fixing and Commissioning of canvas connector for connection of cooler with ducts complete all as specified and directed by engineer in charge - 02 Each Pc M&L for Iron frame stand for mounting of machine & fixing on location all as per the site requirement made out of angle iron of size as per recommended by manufacturer including foundation where necessary, soldering and required found ation ground support all as directed at site the entire satisfaction of department complete all as specified and directed by engineer in charge. - 250 Kg. M&L for control wiring with 5 core X 4 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed. Make : Finloex/Havells/Polycab - 40 RM. Supply & fix Industrial wall mounted plug socket three phase 16 Amp rating 3P+N+ E suitable for IP 67 degree of protection all as specified and directed by engineer in charge.Make- L&T/C&S/ABB/HAVELLS - 02 Each Material & labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts nuts check nuts and washers of galvanised iron strip of size 25 x 4mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necess ary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including tes ting on completion all as specified and as directed. (Note:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.)-01 Each
Suman Uni Controllers (BID ID -3293144)
R.K.TRADING CO. (BID ID -3293609)
Tushar engineers (BID ID -3294194)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_791493.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .