GE NORTH AKHNOOR
GE NORTH AKHNOOR C/O 56 APO
SPECIAL REPAIR TO BLDG NO 106 OR MD ACCN AT RLT VIHAR AT AKHNOOR UNDER GE NORTH AKHNOOR
2022_MES_511678_1
GE(N)/AKH-74/2021-22
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
Class D a i b i
8 documents required · 8 mandatory
₹500
Yes
GE NORTH AKHNOOR
₹80,420
Yes
24 May 2022
3 Mar 2022
30 Mar 2022
3 Mar 2022
28 Mar 2022
15 Mar 2022
Amount
Taking down old treatment incl paddding, removing existing bitumen felt treatment incl brushing,cleaning top surfaces of roof slab, broming etc complete all as specified.
M&L for rendering 10mm thick cement plaster with cement mortar(1:4) on fair finishes of brick work or concrete surface of roof slab all as specified.
Roof treatment :- (a) Apply a coat of biruminous primer conforming to IS - 3384 @ 0.40 Kg/Sqm on prepardd surfaces. (b) After drying of primer apply a coat of hot blown 85/25 penetration grade blown bitumen conforming to (IS-702 @ 1.20 Kg/Sqm of surfaces. (c) Provide APP modified polymeric five layed membrane with central core of 100 micron high molecular high density film. Minium width of APP modified water proofing membrane shall be 3 Kg per Sqm. Product Name Multi p[lus manufactured by M/S STP texa Ltd Gurgoan/Hyper Plus Standard Manufactured by IWL India ltd Chennai, Bengal Acquaflux manufactured by Bengal bitumen New Delhi/Superior plus 310 by STP Lfd and any other product as appproved by E-in-C Br will be used. APP membranne will be laid across the slop from lowest line of slopping roof toward ridge with minimum end lap of 150mm and side lap of 75mm bonded with hot blown. (d) Over the APP membrane apply semi hot blown 85/25 grade bitumen penetration of bitumen when tested as perIS 1203 will not be more than 40/Confiming to IS 702 @ 1.20 Kg/Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bvitumen coat. (e) Coved fillet in PCC (1:2:4) type BO radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall around opening and treatment mentioned above (except fine sand) shall be applied followed by a cement plaster 20mm thick in CM 1:6.
Sunken Floor treatment :- Providing and laying of water proofing treatment to sunken portion by applying cement slurry mixed with acralic based polymer modified cementitious composite compound of make as approved including demolition and filling of sunken floor. (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours. (b) Second layer of slurry of cement Q 0.242 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/ Sqm his layer allowed to air cure for 4 Hours. Note :-Concrete for sunken slabs shall be mixed with WP comounds as manufacturer's instructions before carrying out water proofing treatment the sunken slab slab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested (Note: Water proof compound shall be measured and paid separetaly)
Fixing 10mm dia PVC nozzles and injection grouting using Dr Fix IT URP 301 of M/s Pidilite Industries or equivlent as in sunken floor/ceiling all as per manufacturer's instrutions. Note : Nos and location shall be as directed by Engr-in-charge.
M & L for cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors including screed bed 10mm thick in CM 1:4 all as specified and directed by Engineer-in Charge.
Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc.
M&L for rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement .
M&L for rendering 10 mm thick cement plaster with cement mortar(1:6)on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement.
M & L for provinding 1mm thick wall care putty on walls.
M&L for rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement.
M&L for preparation complete removal of exising treatment of old surfaces complete all as specified.
Supply only liquid water proofing compound
M & L for preparation of newly/Old plastered surfaces of walls and applying two coat of oil bound distemper over one coat of primer all as speicfied and directed.
M&L for preparation of new/old surfaces and apply two coats of cement base paint to walls.including one coat of cement primer.
M& L for preparation of new treated surface and apply two coat white wash on ceiling.
Repairs to balcony/Facia and soffit of chajjas etc by taking down old rendering 20 to 25 mm thick to match with the existing thickness in CM 1:3 and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30Sqm in width or girth incl preparatoin of suface and two coat of cement base paint /apex as reqd over one coat of primer/scaffolding work upto height of 7.0m complete all as specified.
M& L reinforcement cement concrete (nominal mix) type B1 1:2:4 (20mm graded stone aggregatge) for Chajjas/Balcony/Landing work if any including demolition of existing reinforced cement concrete (reinforcement cut as required to facilitate demoltion complete all as specified. all as per specified.
S & F mild steel bars 10mm dia Fe 410W Gde E-250 and over cut to length bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with and includig mild steel wire not less than 0.9mm dia or securing with clips complete fixed in repairs all as specified and directed.
M & L Formwork to sides and soffits/faccia of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, chajja, cantilevers, shelves including sup- ports, overhangs, etc. complete all as specified.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store andd rubbish off the premises
M & L Green Marble work 18mm to 20mm thick (tabel rubbed and polished) in steps of staircase/kitchen platform and like in cement mortar (1:4) inclduing pointing in white cment (1:2) using marble dust with admixture of opigment ot match with marble shade of Green marble including 15mm thick screed bed/base in CM 1:4, roughening/cleaning to existing surface of old concrete floor by picking, sweeping clean and washing down with water to remove dirt/dust and brushing neat cement slurry with 3.0 kg of cement persqm all as specified and as approved by the GE/Engr-in-Charge.
M&L Non skid ceramic coloured tiles600x600x 7 to 8 mm thick (square/ rectangular) in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors/Skirting etc. Set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed.
M&L Glazed ceramic tile 350 x 250 x 06-7mm thick (coloured) on vertical surfaces such as dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering in cement and sand mortar 1:4, complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20mm thick as in riser of steps ,skirting, dado and pillar , over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade or the slab including rubbing and polishing complete including 20 mm thick in CM 1:3 screed for laying kota Stone complete all as specified
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) nexc 1.50 sqm complete all as specified and directed.
M & L Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia thresh old bar and filling hollow of frame of size 125X60mm.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia thresh old bar and filling hollow of frame of size 105x60mm.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.
Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.
PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregate as in filling of pressed steel frame.and including 50 mm parapet coping all as specified etc.
PCC 1:3:6 type C-1 using 20mm graded stone aggregate for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and as directed by Engineer-in-Charge.
S & F 35mm thick Flush shutters, solid core with particle board exterior grade as per IS-2202 of 199 (Part-I). Flush door shutter shall be internally lipped as per clause 8.52.2 of SSR-2009 Part-I complete all as specified and directed by Engr-in-Charge.
S&F Glazed and skelton shutters 30 mm thick second class hard wood, opened rebated and prepared to receive wire mesh etc, edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for sucuring witre mesh etc. Size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.24(a).
Mild steel springs for doors, 150 mm, ordinary rat tail rod pattern springs including roller and roller plate complete.
S&F 100 mm butt hinges, medium weight cold rolled mild steel.
S&F Aluminium handles cast type anodised of size 150mm long ISI marked complete.
S&F Aluminium anodised barrel tower bolt 150 mm, extruded section.
S& F Hasp and stapple safety type of aluminium anodised 100 mm long as a cupboard locker.
S& F aluminium anodised sliding door bolts round nuckle with hasp and stapple extruded section or cast aluminium alloy 300 mm long complete all as specified.
S & F Steel window/ventilator (Box type) factory made with double shutter (wire gauged shutter and glass/glazzed shutter, wire cloth and glass paned shall be measured and paid separately of size 79mm x 39 mm, 16 guage rectangular tubular frame with side hung. fixed in repairs complete all as specified and directed.EUZ/TD/1269/2008 Sheet 1/1 to 1/3.
All as per item No 43 here-in-before but without glazing bars.
S&F Galvanised steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed in repairs.
S&F Glazing with sheet, 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane.
S&F figured glass sheet, 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane.
S&F Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue,nodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed.
M&L pre laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter, 19 mm thick.
M&L pre laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter, 12 mm thick. (Kitchen cup board/covered bottom shelf of cooking platform).
M & L extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails all as specified and directed.
S&F curtain rail, 20 mm dia Stainless steel ,cromium plated fixed with braket, incl taking down of old curtain rods, all as directed.
M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide premier.
M&L for preparation of new untreated wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of pink primer.
Demolition of concrete in ground floor and paving n.exc 15cm thickness (below or above ground level complete all as specified and directed.
Providing cement concrete type C-1, 1:3:6 ( using 20mm graded stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight).
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete.
Taking up or down steel water tubing and connections of 20mm dia bore.
Taking up or down steel water tubing and connections of 15 mm dia bore
Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of 20 mm dia bore
Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of 15 mm dia bore .
S&F stop valves cast copper alloy serwed down high pressure , 15 dia bore fixed in repairs.
S&F stop valves cast copper alloy serwed down high pressure with crutch or butterfly handle 20mm dia bore fixed in repairs.
S&F ball valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball 20mm dia bore.
S&F PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs.
S&F vitreous china squtting pan "Orissa Pattern" size 580 x 440 mm in any coloured with integral foot rest incl lime motor, 'S' trap and complete all as specified, fixed in repairs complete all as specified.
S&F PVC connection 15 mm size with PTMT nuts 450 mm long.
S&F Aluminium anodised towel rail 20mm dia 'D' type 60 cm long between flanges .
S & F stainless steel cockraoch traps Single piece in a box size 101 x 101mm with waste hole complete all as specified fixed in repairs.
S&F Swivel shower of PTMT any colour for fixing with 15 mm pipe ,with shower arm of size 195 mm long with bend of 54 digree with flange of any colour (minimum weight 40 gm), supplied and fixed in repairs complete.
Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern), includding all fittings, heads , shoes bends , swan-necks etc complete all as specified.
S & F 110mm bore PVC SWR Type-B pipes single socket in any length with rubber joints fixed in floors etc all as specified and directed.
S & F in repairs PVC SWR bends any radius 110 mm bore all as specified.
S & F sand PVC waste pipes 110mm dia in any length fixed to walls with PVC//MS holder but clamps and conforming to IS-1729 complete all as specified and directed.
All as description of Srl No 74 above but 75mm bore.
S&F PVC Bends (any radius) diminishing pieces or tapers (larger bore measured) for pvc pipes fixed in repairs, 110 mm bore complete all as specified and directed.
S & F PVC branch pipes 110mm single equal or unequal ordinary or inverted (spigot or socket type) fixed in repair with paralled branches all as specified and directed.
S & F PVC branch pipes 110mm double equal or unequal ordinary or inverted (spigot or socket type) fixed in repair with paralled branches all as specified and directed.
S & F PVC junction, single, equal or unequal, ordinary or inverted with spigot or socket branch of 75mm bore complete all as specified and directed.
Add to Srl item 78 here -in- above if provided 110mm bore with access door PVC cover complete all as specified.
S & F PVC cowls 110mm fixed in repairs all as specified directed.
S & F PVC 75mm vent horn fixed in repairs complete all as specified.
S & F PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified.
S & F Plate rack made of stainless steel 0.8mm thick overall size 786mm x 610mm x 254mm complete all as specified and directed.
S & F kitchen sink with solo regular single bowl gloss finishing stainless steel 1.00 mm thick sheet for kitchen with plugs, washers and wastes including fixing in reinforcement cement concrete slab and connecting union to pipe overall 510 x 430 x203 supplied and fixed in repairs with complete fittings all as specified and as directed by Engineer-in-Charge.
S & F CP angle valve/concealed stop cock of cast copper alloy (ISI Marked) chromium plated fancy type scrwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore incl add if fixed in repairs complete all as specified and directed.
S & F Bib taps (Long body) , fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified.
S & F CP Brass wall mixture with Telephonic shower arrangement for mixing hot cold water supply screwed down incl connecting legs & wall flanges for iron pipe 15mm dia bore fancy type in repair complete all as specified and directed.
M&L Brick work with sub class 'B' bricks , straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 including demolition of existing brick work built in cement mortar including all quions, arches , pillars etc.
M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed.
M & L Sand filling under floors or in foundation similar works complete all as specified and directed.
M&L grubbing up bucks, tree trunk in portion exc. 30 cm and not exc 100cm girth of tree including cutting of trees/bushes grown on over wall and roots digging out roofs and marks good distance of wall/ roof with PCC 1:3:6 type and using 20mm graded stone aggregate, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc 50m and clearing site complete all as specified and directed.
S&F mild steel hand rails, half round or other steel section or core wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or reveting etc, and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling of wrought iron or wild steel work of any description not otherwise provided for complete all as specified and directed.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
M&L for Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch, complete all as specified & directed.
All as per Srl item No. 96 here-in-above but for one 5 pin 6 Amps socket outlet on independent board.
All as per Srl item No. 96 here-in-above but for one 5 pin 6 Amps socket outlet on same board with other switches.
M&L for point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volt grade, single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling/false ceiling including cutting chases as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 16 Amps controlled by one switch on independent board, complete all as specified & directed. Notes for Srl Item No. 96 to 99 (i) Unit rate includes for cutting chases whereever required and sinking for boxes, making good to walls / floors etc., complete, including white wash / colour wash as directed. (ii) Uniform coding of wiring i.e red / yellow / blue for phase black for neutral and green for earth is to be maintained.
Supply & fixing modular type switch 6 Amps, single pole, 1way,1 module,240V, ISI Marked complete all as specified and directed. Make Indoasian Glint,Crabtree, Havells REO
Supply & fixing modular type switch 16 Amps, single pole, 1way,1 module,240V, ISI Marked complete all as specified and directed. Make Indoasian Glint,Crabtree, Havells REO
Supply & fixing modular type socket 6 Amps -2/3 Pin combined shuttered socket 2 module 240V AC ISI Marked Complete all as specified and directed .Make Indoasian Glint,Crabtree, Havells REO
Supply & fixing modular type socket 6 A/16 Amps -2/3 Pin combined shuttered socket 2 module 240V AC ISI Marked Complete all as specified and directed .Make Indoasian Glint,Crabtree, Havells REO
Supply & fix fan regulator modular type electronic, stepped type 100 Watts, 2 module 240Volts,AC ISI marked complete all as specified and directed. Make Indoasian Glint,Crabtree, Havells REO
S&F ceiling rose 5 amp, 3 plates polycarbonate body complete all as specified & directed.
Supply and fixing buzzer, ding dong AC, 230 volts single pole complete all as specified and directed. Make ANCHOR (ROMA), HAVELLS (CRABTREE), LEGRAND
S & F modular bell push 6A , 1 module, 240V, ISI Marked Complete all as specified and directed. Make ANCHOR (ROMA), HAVELLS (CRABTREE), LEGRAND
Supply and fixing sheet metal enclosure double door type for DBs single pole and neutral 12 way 240 V with 200 Amp bus bar including blanking plates where required including fixed flush in wall chases wall for fixing DB and making good surfaces to match with existing surface all as specified and directed. Make : Indoasian, Legrand, Schiender, Havells etc.
S&F in replacement MCB, single pole, (SP) 6 to 32 Amp, AC, 10 KA repturing capacity, ISI marked, 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed by Engineer-in-Charge.
Supply & fix MCB SPN 32 to 40 Amps 10 KA,"C" series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed Make : Legrand, Schiender, Havells etc.
M&L for Sub main wiring with two runs of 10.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through in and including PVC surface conduit or casing caping of 20/30mm, 2.0 mm wall thickness (ISI marked) with all fittings and fixing accessories, surface type on walls, roofs etc including one run of 6.0 Sqmm FRLS PVC insulated copper conductor for earth continuity wire in green color including taking down carefully existing copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete all as specified & directed by Engineer-in-Charge. Note:- Two runs of copper conductor 10.0 sqmm and one run of 6.00 Sqmm copper earth wire including PVC casing caping will be measured and paid as one unit only.
S&F Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 metre below normal ground level, surrounded on all sides by 150mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to and including earth lead wire 4.0mm (8SWG) by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) including taking down old existing earthing complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of size shown in electrical plate No.3, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if the earth resistance equal or less 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
Taking down UNSV flourescent fitting and M & L for LED batten Regal suitable for T8 LED tube incl T8 LED tube crystal glass with very high efficacy suitable for installation in existing T8 fitting with G13 lamp 20 watt 4 ft long all as specified and directed. Make : Havells Part No for batten- REGALBATTENT8UPTO1X22W DSBSWH, Cat Part No- LED Tube T8 : CRYSTAL1213T8DSTL18WLED865SGLASS or equivalent in CG, Philips, Bajaj . Note :- Rate quoted include the cost of both batten and Tube rod T8 and shall match with the batten
Supply and fixing ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) incl taking down existing old unserviceable ceiling fan of any type from existing location and deposit with MES store yard complete all as specified and directed.
Material & Labour for surface & wall mounted LED tube light fitting 10W, 2 feet long extruded PVC housing provided for efficient heat dissipation to polycarbonate diffuser & integrated electronic driver with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make- Havells catpart No ENDURALINEARNEOBS10W LED865SPCWH OR equivalent in Philips/ Crompton/ Bajaj/ Wipro
Taking down old unserviceable Exhaust fan of any type/size from existing location and deposit in MES store yard and Supply and fix exhaust fan single phase metal body, AC 230 Volt, 50 Hz of size 300mm sweep with louvers shouter complete with all accessories including connecting up from ceiling rose to motor all as specified and directed. Make : Havells, Bajaj, Cromption etc.
S & F in replacement of 20 Watt LED energy saving light fitting environment friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 with GI bracket made of light grade GI pipe 40 mm dia of 1.2 mtr long bend to shape with 02 Nos of FI clamp 32 x 4mm with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed . (Make- Havells, cat part No ENDURACITYLITEPLATSL20WLED757SASYBOPC or Bajaj/Philips/Crompton Greaves or its equivalent).
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 50 Sqmm 3.5 core laid in trenches or passing through pipes complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately) Make: Polycab, Gloster, Grandlay
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 mtr deep and getting out complete in any type of soil complete all as specified and directed
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed by Engineer-in-Charge.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
PACHNANDA BUILDERS
JR CONSTRSTRUCTION CO.
M/s Sekinder Paul Sharma
M/s Rajesh Kumar Contractor
M/s Joginder Lal Malhotra
M/S Mahajan Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .