Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹25.8 L+₹54,374 (2.15%)Rejected-Finance 60 4 MOTILAL GUPTA ROAD GROUND FLOOR KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹42.3 L+₹17.0 L (67.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
25 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF EXTERNAL ELECTRIC SUPPLY AT OTM AND MD ACCN INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2024_MES_644317_1
8226/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹79,000
31 Mar 2024
27 Feb 2024
26 Mar 2024
27 Feb 2024
25 Mar 2024
11 Mar 2024
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation or for shafts, wells cesspits, manholes etc., not exceeding 10 sqm on plan and getting out in soft/loose soils, complete all as specified and directed.
Excavation /Cutting Road/Hardstanding in trenches not exceeding 1.5 metre in depth & not exceeding 10 sqm on plan complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 metre and deposited where directed at a level not exceeding 1.5 metre above the starting point in soil complete all as specified and directed.
M&L for sand cushioning as per para 19.75 of SSR Part-I(2009) in trenches for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and directed by engineer-in-charge. NOTE: Punned thickness only shall be measured for payment.
M&L for Brick protection with subclass ‘B’ bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified.
Laying Only Serviceable Bricks after cleaning by wire brush obtained from taking out unserviceable LT cable in connected items here-in-after.
Taking out of interlocking paver block, any shape or size and Re-laying the same after removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed. (NOTE: Sand, if required for correction of cushioning level will be measured and paid seperately. Replacement of broken paver block shall be paid seperately as "Supply only")
Material and labour for machine pressed precast concrete interlocking paver block with grey cement and pigmnent of any shape and size as approved by GE conforming to IS 15658-2006 of 60 mm thickness, M-35 grade complete all as specified and directed.
Taking down unserviceable LT cable of size 10 -16 Sqmm of any Core, for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge (Note :- Necessary earth work to be measured and paid separately.)
All as per Srl Item No 10 here-in-before but size of cable 25-50 Sqmm
All as per Srl Item No 10 here-in-before but size of cable 70-150 Sqmm
All as per Srl Item No 10 here-in-before but size of cable 185-240 Sqmm
All as per Srl Item No 10 here-in-before but size of cable 300-400 Sqmm
Supply laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core laid in trenches or fixed to wall with saddles/flat iron clamps as per site requirements/passing through pipes/poles complete all as specified and directed by Engineer-in-charge. Note: Necessary earth work to be measured and paid separately.
All as per Srl Item No 15 here-in-before but size of cable 35 Sqmm, 3.5 Core.
All as per Srl Item No 15 here-in-before but size of cable 50 Sqmm, 3.5 Core.
All as per Srl Item No 15 here-in-before but size of cable 95 Sqmm, 3.5 Core.
All as per Srl Item No 15 here-in-before but size of cable 150 Sqmm, 3.5 Core.
All as per Srl Item No 15 here-in-before but size of cable 185 Sqmm, 3.5 Core.
Re-laying of serviceable XLPE insulated, armoured heavy duty electric cable (obtained from above connected items) 1100 volts grade, cross-sectional area 10 to 16 Sqmm, 2/3.5/4 core laid in trenches or fixed to wall with saddles/flat iron clamps as per site requirements/passing through pipes/poles complete all as specified and directed by Engineer-in-charge. Note: (a) Necessary earth work to be measured and paid separately. (b) Serviceable cable use only after decision of board of officer conveyed by Accepting Officer.
All as per Srl Item No 21 here-in-before but size of cable 25-50 Sqmm, 3.5/4 Core.
All as per Srl Item No 21 here-in-before but size of cable 70-150 Sqmm, 3.5 Core.
All as per Srl Item No 21 here-in-before but size of cable 185-240 Sqmm, 3.5 Core.
All as per Srl Item No 21 here-in-before but size of cable 300-400 Sqmm, 3.5 Core.
M&L for MCCB 4 Pole, 415 V, with Microprocessor release 630 Amps with breaking capacity 50 KA complete all as specified and directed by Engineer-in-charge.
M&L for MCCB 4 Pole, 415 V, with Microprocessor release 400 Amps with breaking capacity 50 KA complete all as specified and directed by Engineer-in-charge.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 320 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-charge.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-charge.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-charge.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-charge.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 25 KA complete all as specified and directed by Engineer-in-charge.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 KA complete all as specified and directed by Engineer-in-charge.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 18 KA complete all as specified and directed by Engineer-in-charge. Note for item No. 13 to 21 :- (i) MCCB Should be calibrated at 50°C for accurate performance in higher ambient. (ii) Over load Protection of MCCB should be adjustable 63-100% of nominal Current. (iii) Short Circuit Protection of MCCB shall be adjustable 6 to 10 times in nominal current. (iv) Neutral Protection of MCCB Shall be adjustable to OFF/50% & 100%
Supply and fixing 80 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor incl taking down of old unserviceable GI pipe complete all as specified and as directed by the Engineer-in-charge.
All as per Srl Item No 35 here-in-before but size 100 mm bore.
S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the 10 Sqmm to 16 Sqmm, 4 core size of cables :-
All as per Srl Item No 37 here-in-before but size 25 Sqmm to 50 sqmm 3.5/4 core
All as per Srl Item No 37 here-in-before but size 70 sqmm to 150 sqmm, 3.5 core
All as per Srl Item No 37 here-in-before but size 185 sqmm to 240 sqmm, 3.5 core
All as per Srl Item No 37 here-in-before but size 300 sqmm to 400 sqmm, 3.5 core
S&F Cable Route Indicator made out of Cast Iron plate 80 mm dia fixed with MS angle iron 40x40x6mm having 60 Cm long showing MES LT Cable Size with voltage with two coats of synthetic enamel paint in blue colour over one coat of primer necessary Earth Work and Cement Concrete 1:2:4 (20mm graded crushed stone aggregates) Block of size 20x20x20 Cm including Taking out Unserviceable Cable Route Indicator, complete all as specified and as directed.
Material & Labour for PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
Dismantling/ Disconnecting electric connection of underground LT, XLPE Cable, 1100 volts upto 35 to 400 Sqmm from both sides and locating the fault in LT cable with fault locating machine in the entire length complete testing after reconnecting and commissioning of cable complete all as specified and as directed. Note : The work will be executed after obtaining proper shutdown from main power house liase with concern JE E/M.
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1400mm x 1400mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 500 Amps of adequuate size for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 600mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories:- Make : Star Electric & Engg Co/ CPRI approved. (a) Manual change over switch 315 Amps, 4 pole, 415 volts,opern execution type - 01 Nos. (b) MCCB adjustable type with thermal-magnetic releases of capacity 320 A, 4P, 36 KA with spreader terminals - 02 Nos(I/C) (c) MCCB adjustable type with thermal-magnetic releases of capacity 200A, 4P, 25 KA with spreader terminals - 02 Nos(O/G) (d) MCCB adjustable type with thermal-magnetic releases of capacity 100A, 4P, 25 KA with spreader terminals - 03 Nos(O/G) (e) MCCB adjustable type with thermal-magnetic releases of capacity 63A, TPN, 10 KA with spreader terminals - 02 Nos(O/G)
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1500mm x 1500mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 600 Amps of adequuate size for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 600mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories:- Make : Star Electric & Engg Co/ CPRI approved. (a) Manual change over switch 400 Amps, 4 pole, 415 volts,opern execution type - 01 Nos. (b) MCCB adjustable type with thermal-magnetic releases of capacity 400A, 4P, 36 KA with spreader terminals - 02 Nos(I/C) (c) MCCB adjustable type with thermal-magnetic releases of capacity 200A, 4P, 36 KA with spreader terminals - 01 Nos(O/G) (d) MCCB adjustable type with thermal-magnetic releases of capacity 160A, 4P, 25 KA with spreader terminals - 01 Nos(O/G) (e) MCCB adjustable type with thermal-magnetic releases of capacity 100A, 4P, 25 KA with spreader terminals - 02 Nos(O/G) (f) MCCB adjustable type with thermal-magnetic releases of capacity 80A, 4P, 25 KA with spreader terminals - 03 Nos(O/G)
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1400mm x 1300mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 500 Amps of adequuate size for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 600mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories:- Make : Star Electric & Engg Co/ CPRI approved. (a) Manual change over switch 315 Amps, 4 pole, 415 volts,opern execution type - 01 Nos. (b) MCCB adjustable type with thermal-magnetic releases of capacity 320 A, 4P, 36 KA with spreader terminals - 02 Nos(I/C) (c) MCCB adjustable type with thermal-magnetic releases of capacity 200A, 4P, 36 KA with spreader terminals - 01 Nos(O/G) (d) MCCB adjustable type with thermal-magnetic releases of capacity 160A, 4P, 25 KA with spreader terminals - 01 Nos(O/G) (e) MCCB adjustable type with thermal-magnetic releases of capacity 63A, 4P, 25 KA with spreader terminals - 04 Nos(O/G) (f) Surge Protection Device 3P+N, 50 KA, 415 Volts, 50 Hz - 02 Nos.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6.0mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge not less than 1.5 m below ground level,connected to galvanised Iron strip 25 x 4 mm by means of bolts, nuts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 5 of SSR part I, connected to earth test point all as specified or indicated complete with Excavation, earth work, PCC 1:3:6 pit with RCC M25 (design mix) cover 54cm x 54cm x 50 mm thick reinforced with hard drawn steel wire fabric weighing exceeding 4 Kg/Sqm with suitable handle made of 10mm dia MS bar, 20 mm bore GI tubing medium grade for watering pipe, 15 mm bore upto 7.5 mtrs medium grade GI pipe for protection of earth lead, test point, GI funnel with 4 mm wire mesh all as directed and specified and testing on completion.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S BISWANATH BHATTACHARJEE
Commercial Electric Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .