Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹19.1 L+₹13,754 (0.73%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Sept 2021, 6:00 pmClosed
GE Kamptee
Garrison Engineer Kamptee Cantt Area 441001
REPAIRS/ REPLACEMENT TO UNDERGROUND CABLE, MAINT AND REPLACEMENT OF LT PANEL/CAPACITOR BANK AND CONNECTED ITEMS OF DISTRIBUTION SYSTEMS IN GRC, NCC, APS AND MH AREA UNDER GE KAMPTEE.
2021_MES_470611_1
8313/E8
Open Tender
Civil Works
Works
180 days
Kamptee
Class E, Cat b (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹40,000
Yes
18 Oct 2021
25 Aug 2021
22 Sept 2021
25 Aug 2021
20 Sept 2021
8 Sept 2021
Amount
Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables,poles, stay and getting out of excavated material complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed .
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed Make:- Dura. Line/Tijaria/REX/Ketron
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 63 mm outer diameter and 51 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed Make:- Dura. Line/Tijaria/REX/Ketron
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 90 mm outer diameter and 76 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed Make:- Dura. Line/Tijaria/REX/Ketron.
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed . Note :- laying of cable route indicator is same as old cable route .
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 120 sq mm, 3.5 core including testing after laid and jointed all as specified and as directed Make :- Gloster/ Polycab/Havells Note:- Excavation and earth work,cable protection shall be measured and paid separetely.
All as per item No. 8 but cable size 95 sq mm 3.5 core all as specified and as directed.
All as per item No. 8 but cable size 35 sq mm 3.5 core all as specified and as directed.
All as per item No. 8 but cable size 16 sq mm 4 core all as specified and as directed.
All as per item No. 8 but cable size 10 sq mm 4 core all as specified and as directed.
Supply and fix LED street light luminaires of capcity 60 watts with pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection complete with driver, 1.2 mtrs suitable size GI bracket,1.5 sqmm 3 core multistranded copper wire for connection from street light fitting to junction box,fixing with 30x5 mm Flat Iron clamps nuts, bolts, washers and fixing accessories including taking down old unserviceable fitting all as specified and as directed
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 30 x 5 mm by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40mm bore, light grade 7.5m long as applicable and as per plate No. 5 of SSR 2009 and all as specified. (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode (c) PCC pit in cement concrete (1:2:4) type B-1 (d) 40 mm thick Pre-cast RCC cover with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore ,medium grade & copper lug etc. (f) 40mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion.
Supply and fix Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 Sq mm. Note :- Any Excavation and earth work ,Returning and filling, Removing involved shall be measured and paid seperatelay
All as per item No. 15 but cable size 70 - 120 sq mm cable size complete all as specified and as directed.
All as per item No. 15 but cable size25 - 50 sq mm cable size complete all as specified and as directed.
Supply, erecting & fixing steel tubular swaged pole complete with base plate, pole cap, nut bolt washer etc 8.5 meters long type 410 SP-22 swaged poles conforming to IS 2713 (Part-I to III) 1980 all as specified including two coats of black bitumen paint through out internally and externally upto planting depth and applying two coats of aluminum paint over one coat of red oxide primer (externally) and Numbering of poles as directed including excavation /earth work, PCC (1:4:8) type D-2 using 40mm aggregate for pole foundations of size 600x600x1500mm height upto ground level and using PCC (1:2:4) B-1 for coping with size 450x450x300mm including necessary formwork complete with taking down old unserviceable pole all as specified and directed.
Supply and fixing thermoplastic cable junction boxes IP 55/IP65 with metric knockout for Cable entry fixing on pole with mm MS clamps, nut bolts, washers, terminal block and glands suitable for 16/25 Sq mm core cable CAT No. Hensel K 9255 equiv in Neptune/Cape including 6 amps MCB SP and all as specified and directed
Supply and fixing thermoplastic cable junction boxes IP 55/IP65 with metric knockout for Cable entry fixing on pole with mm MS clamps, nut bolts, washers, terminal block and glands suitable for 16/25 Sq mm core cable CAT No. Hensel K 9502 or equiv in Neptune/Cape complete all as specified and directed
S&F LED driver for 60W LED street light fittings complete all as specified and as directed.
S&F LED driver for 45W LED street light fittings complete all as specified and as directed.
S&F LED driver for 25/30W LED street light fittings complete all as specified and as directed.
S&F LED Surge protector for LED street light fittings complete all as specified and as directed.
M&L for plain cement concreate (1:3:6) type C-1 using 20 mm graded stone aggregate as in copping of pole including necessary form work weathering slightly rounded or clamfered angles & throating exposed surfaces finished fair and even complete all as specified & directed.
Taking down the unserviceable LT Panel of any size complete with all accessories all as specified and as directed.
Supply, install, test and commissioning of LT panel board / feeder pillar box, outdoor cubicle type, vermin proof, dust proof (of CPRI approved manufacturer), fixed on 50x50x5mm MS angle iron frame fixed 300mm above groung level and 450mm below the ground level grouted in and including PCC (1:3:6) type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm hick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN suitable for 300 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, suitable size to accommodate and consisting of the following items, all as specified and as directed (a) Busbar chamebr for 3 phase & nuetral of capacity 300 Amps (30mm x 10mm) alumunium bus bar duly insulated, (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos (c) one set of pilot lamp. (d) Incoming MCCB 160 amps 4 Pole 415 volts 25 KA thermal magnetic setting type- 1 Nos (e) Outgoing MCCB 63 amps 3 pole 415 volts 10 KA thermal magnetic setting - 5 Nos (f) Outgoing Type MCB 63 amps 3 Pole 415 volts 10 KA - 2 Nos
Supply, install, test and commissioning of LT panel board / feeder pillar box, outdoor cubicle type, vermin proof, dust proof (of CPRI approved manufacturer), fixed on 50x50x5mm MS angle iron frame fixed 300mm above groung level and 450mm below the ground level grouted in and including PCC (1:3:6) type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm hick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN suitable for 400 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, suitable size to accommodate and consisting of the following items, all as specified and as directed. (a) Busbar chamebr for 3 phase & nuetral of capacity 400 Amps alumunium bus bar duly insulated, (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos (c) one set of pilot lamp. (d) Incoming MCCB 320 amps 4 Pole 415 volts 25 KA thermal magnetic setting type- 1 Nos (e) Outgoing MCCB 200 amps 3 pole 415 volts 25 KA thermal magnetic setting - 4Nos (f) Outgoing MCCB 100 amps 3 pole 415 volts 25 KA thermal magnetic setting - 2 Nos
Supply, install, test and commissioning of wall mounted LT panel board outdoor type, vermin proof, dust proof (of CPRI approved manufacturer),made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm hick for inner shell front side openable frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing on wall with i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN suitable for 300 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, suitable size to accommodate and consisting of the following items, all as specified and as directed (a) Busbar chamebr for 3 phase & nuetral of capacity 300 Amps alumunium bus bar duly insulated, (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos (c) one set of pilot lamp. (d) Incoming MCCB 200 amps 4 Pole 415 volts 25 KA thermal magnetic setting type- 1 Nos (e) Outgoing MCCB 125 amps 3 pole 415 volts 25 KA thermal magnetic setting - 1 Nos (f) Outgoing MCCB 100 amps 3 pole 415 volts 25 KA thermal magnetic setting - 2 Nos (g) Outgoing MCCB 63 amps 3 pole 415 volts 10 KA thermal magnetic setting - 1 Nos
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.53,955.00]
Paragon Electrotechnics
Bidder Name
Paragon Electrotechnics
Vaidehi E Link
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .