Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | single₹75.0 LAccepted-AOC 10 NIGAHI MODE P O NIGAHI DISTT SINGRAULI M P | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486884 | single | Accepted-AOC Awarded as per NIT | |
| 2 | Rejected-Technical 17 A SHYAMA JI PURAM I I T SOCIETY IIT KALYANPUR KANPUR UTTAR PRADESH 208016 | KANPUR NAGAR | UTTAR PRADESH | 208016 | - | Rejected-Technical As per NIT |
Tender Value
₹96.2 L
EMD Value
₹1.2 L
Closing Date
20 Mar 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (EM)
Office of the General Manager Khadia Area Sonbhadra 231222 (UP)
Day to day LT overhead line work as and when required basis for a period of two years in Khadia Project
2024_NCL_303095_1
KHD/EM/E-Tender/23-24/547 DT 28.02.2024
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
Khadia Project
Please refer NIT
4 documents required · 4 mandatory
₹1.2 L
30 Sept 2024
29 Feb 2024
22 Mar 2024
29 Feb 2024
20 Mar 2024
1 Mar 2024
29 Feb 2024 - 10 Mar 2024
Amount
DISMANTLING AND STACKING OF
ACSR rabbit/equivalent conductor with opening of jumper
Pin/Shackle insulator with hardware
GI Earth wire 7/14 SWG
Steel material such as : MS channel bracket, angle, clamp, support, plate, pipe nut & bolt etc.
Danger board with clamp, bracket, nut and bolts
11M To 16M Tubular/Rail poles
Stay set with stay wire, stay clamp and stay insulator
Main switch/MCB/MCCB/RCCB box 20 to 200 Amp from pole,Tower etc.
PVC spacer from OHL
Dismantling of all type of old and new lights fitting on Pole/Tower/other location as per direction of EIC
ERECTION
Laying stringing, tensioning of ACSR rabbit / equivalent AAAC conductor with jumpering
Laying, stringing, tensioning of GI earth wire
Fabrication of Steel material such as : MS channel bracket, angle, clamp, support, plate etc.(Steel material, welding rod, Gas are departmentally provided and other things such as, Welding M/c, Cutting Set etc. are provided by contractor)
Erection of Steel material such as : MS channel bracket,angle,clamp, support, plate, pipe nut & bolt etc.
Installation of Main switch/MCB/MCCB/RCCB box 20 to 200 Amp on pole,Tower etc.
Installation/ fixing of anticlimbing device or barbed wire by wounding on required height on the poles
Erection of steel tubular pole/rail pole exceeding 11m but not exceeding 16m in brick blast/local hard stone, concreting with cement, local sand and mine gravels including excavation of the pit size 0.8 x 0.8 x 1.6m.
Excavation of stay pit size 0.6x0.6x1.2m & refilling in all kind of soil including soft rock
Concreting of stay pit with cement, mine gravels and local sand in the ratio 1:4:8
Excavation of earth & refilling it in any type of soil as & when required.
Concreting for old pole/stay including muffing with cement,mine gravels and local sand in the ratio 1:4:8
Erection of stay set complete including binding, tensioning with 7/10 SWG stay wire and stay insulator with back clamp on pole
Fixing/Erection of shackle/pin insulator with hardware complete
Installation,fitting , testing and commissioning of all type of old and new light fitting on pole as per direction of EIC
Opening the jumper and rejumpering (Three no in one Set)
Providing guarding on the line including fixing of brackets as per requirement.
Erection of danger boards with bracket and fasteners on required height of LT poles, switches and isolators
Laying loading unloading of 1.1 KV grade cable of different sizes; erection on pole mounting of 440 V OHL including jumpering work and dismentling from poles,switches and isolators
Shifting and erection or dismantling of 15/16.2 mtrs long light moving tower as required as per direction of EIC (Crane departmently provided)
Supply and fixing of 4/5 wire PVC phase separator of superior quality of 1.1 KV grade including labour charge for all phase including lighting
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as .required. All items supply by contractor.
Total impact of GST for the purpose of CTC
techsummary_313971.pdf
PDF • 0.19 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_313971.pdf
PDF • 0.19 MB
LOA.pdf
PDF • 14.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .