Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.2 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹42.5 L+₹3.5 L (9.04%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹45.5 L+₹6.5 L (16.6%)Rejected-Finance | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹45.8 L+₹6.9 L (17.6%)Rejected-Finance | 4 | Rejected-Finance Not being the lowest bidder | |
| 5 | 5₹46.7 L+₹7.8 L (20.0%)Rejected-Finance | 5 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Feb 2020, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
OUTSOURCING OF SERVICES FOR PERIODICAL MAINTENANCE AND REPAIRS TO SPLIT AC WINDOW AC WATER COOLERS AIR COOLERS CASETTE AND VERTICAL AC AT CPDC AND ELSEC UNDER GE I RND RCI HYDERABAD
2020_MES_314760_1
8538
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
335 days
GE I R AND D RCI
MES enlisted Class D category c i and d v Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
₹90,000
Yes
29 May 2020
14 Jan 2020
28 Feb 2020
14 Jan 2020
24 Feb 2020
28 Jan 2020
Amount
Outsourcing of services for periodical checking and day to day maintenance and attending complaints of all Water Coolers, Evaporative Desert Coolers and Window type ACs including cleaning of Water Coolers, Evaporative Desert Coolers and Window type ACs such as evaporator units, condensor coil refrigerant system and electrical controls etc., at RCI Technical Area including K-15, War Head, DSC area, ELSEC and CPDC area by providing Four Refrigeration Mechanics per shift of 8 hours for One shift in a day on all days except Sundays and Holidays complete all as specified and directed.
Outsourcing of services for periodical checking and day to day maintenance and attending complaints of all Split ACs of 1.5 Ton, 2/3(2 x 1.5) Ton capacity including cleaning such as filter units, evaporator units, condensor coil, refrigerant system and electrical control etc., at RCI Technical Area including K -15, War Head area, DSC area, ELSEC and CPDC area by providing Four Refrigeration Mechanics per shift of 8 hours for One shift in a day on all days except Sundays and Holidays complete all as specified and directed.
Outsourcing of services for periodical checking and day to day maintenance and attending complaints of all Split ACs of 1.5 Ton, 2/3 (2 x 1.5) Ton capacity, Cassette type ACs, Vertical type ACs including cleaning such as filter units, evaporator units, condensor coil, refrigerant system and electrical controls etc., in RCI Technical Area Community Hall, DSC area, GE Office, MI Room area by providing Two Refrigeration Mechanic per shift of 8 hours for One shift in a day on all days except Sundays and Holidays complete all as specified and directed.
Notes for the serial item No 01 to 03: All T&P for operating, repair and maintenance are deemed to be included in the unit rates quoted.
All stationary for Duty Roster, Attendance register, Wages register, Log sheet book, maintenance record etc., shall be arranged, maintained and submitted by the contractor to Engineer in charge in the first week of every month.
Any loss due to negligence, mis operation shall be made good by the contractor without any extra cost to the department.
Wage period shall not exceed one month. Wages for all workers employed shall be paid before 7th day of every month through bank account without fail irrespective of whether RAR is claimed or not.
Non compliance on the part of contractor for not making payment of wages to workers as stipulated above shall attract penalty at the rate of Rs 100.00 per shift per worker from RAR/Final Bill. No claim whatsoever on this account will be entertained.
Minimum wages, EPF, ESI, Bonus etc., to the workers shall be paid by the contractor as per Regional Labour/PF Commissioner Gazette Notification including DA all as authorised.
Labour elements for fixing of other spares/parts mentioned in this schedule as supply only shall be deemed to include in the unit rate quoted.
The complaints received from the users duly enclosed in the register with docket number and complaint slip has to be maintained with user signature after satisfactory attending the compliant as a token of completion indicating showing the spares replaced wherever applicable.
The workers employed by the contractor for outsourcing shall be entitled for one day weekly off and the contractor has to provide suitable substitute in the concerned shifts. The unit rate quoted shall be deemed to include for this provision.
Taking down window type air conditioner of any capacity by disconnecting all electric connections, cleaning the components i.e. condenser coil and evaporating coil with caustic soda and fixing back to its original position and reconnecting the AC with the electrical connections including testing complete all as specified and directed.
Taking down the old unserviceable compressors, supply and fix new hermetically sealed Rotary / Reciprocating compressors suitable for window type air conditioner of 2Ton capacity with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, pressure testing the complete system with nitrogen after carrying out repairs, flushing out the complete system, vaccumising and gas charging with R-22 refrigerant gas to obtain designed cooling, closing of suction and discharge valves complete all as specified and directed.
All as per item No 5 above but of 1.5Ton capacity for window type air conditioner. Make for item No 5 & 6: Kirloskar/Copeland/Tecumesh/ Bluestar
All as per item No 5 above but of 2Ton capacity for split type air conditioner.
All as per item No 5 above but of 1.5Ton capacity for split type air conditioner.
All as per item No 5 above but of capacity 4.5TR for cassette type / vertical type air conditioner. Make for item No 7, 8 & 9: Carrier/Bluestar/LG/Hitachi /Tecumech/Kirloskar Note for item No 4 to 9: Labour required for carrying out the job shall be from the outsourcing persons employed under Sl item No 1 to 3 above.
Supply only Relay assembly for the window type air conditioners of 2 Ton capacity complete all as specified.
Supply only Relay assembly for the window type air conditioners of 1.5 Ton capacity complete all as specified.
Supply only Thermostat switch including knob plate for the window type air conditioners of 1.5/2 Ton capacity complete all as specified.
Supply only Starting Capacitor 120/150 MFD for window / split type air conditioners of 2 Ton capacity complete all as specified.
Supply only Starting Capacitor 80/100 MFD for window / split type air conditioners of 1.5 Ton capacity and water coolers of any capacity complete all as specified.
Supply only Running Capacitor 45/50 MFD for window / split type air conditioners of 2 Ton capacity complete all as specified.
Supply only Running Capacitor of 50 + 2 & 60 MFD for the window / split type air conditioners of 2 Ton capacity complete all as specified and directed.
Supply only Running Capacitor 36 MFD for window / split type air conditioners and water coolers of any capacity complete all as specified.
Supply only 2.5/4 MFD capacitor for fan motor of window / split type air conditioners and water coolers of any capacity complete all as specified.
All as per item No 18 above but 6/10 MFD capacitor for vertical / cassette type ACs complete all as specified.
Leak testing of complete gas circulating system with dry nitrogen, flushing out complete system, vaccumising, supplying and charging the R-22 refrigerant gas including replacement of unserviceable of copper filter, capillary tube, ‘U’ foam etc., with new ones, cutting brazing, leak detection and rectification etc., for window type Air Conditioner of 1.5/2 Ton capacity complete all as directed. Note: Nitrogen to be arranged by the contractor
Taking out the unserviceable dual speed blower fan motor 0.2(1/5)HP of window AC by disconnecting all electrical connections, opening the same and rewinding the burnt out motor with super enamelled copper wire duly insulated including replacement of bushes, mounting rubbers etc., with new ones, reassembling, reconnecting and testing complete all as specified and directed.
Supply only FR PVC insulated, round sheathed 4core 2.5Sqmm, multistranded copper conductor industrial cable, 1100V grade, ISI marked complete all as specified.
Supply only balanced Centrifugal blower for the window type air conditioners of 1.5/2 Ton capacity complete all as specified.
Supply only MCB, SP, 32Amps, 10KA, 240volts, ISI marked complete all as specified. Make: Legrand CAT No 4085 95 or equivalent in Siemens / L&T / IndoAsian as approved by GE
Supply only 3 Pin Industrial plug top suitable for industrial metal clad socket single phase 230 Volts complete all as specified. Make: IndoAsian / L&T / Havells / Legrand
Supply only Industrial Socket (metal clad socket) single phase 230 Volts complete all as specified. Make: IndoAsian / L&T / Havells / Legrand
Taking down the water cooler of any capacity by disconnecting all electric connections, cleaning the components i.e., condenser coil, evaporating coil including inner tank with caustic soda and fixing back to its original position and connecting up with electrical connections complete all as specified and directed.
S&F in repairs hermetically sealed compressors for water cooler of 40/80litres capacity with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, flushing out the complete system, pressure testing the complete system with nitrogen after carrying out repairs, vaccumising and gas charging with refrigerant gas to obtain designed cooling closing of suction and discharge valves complete all as specified and directed
All as per item No 28 above but for water cooler of 60/120 and 60/150 litres capacity Make for item No 28 & 29: Kirloskar/Tecumesh/ Bluestar/Copeland
Supply only Relay assembly for water cooler of 40/80 capacity complete all as specified.
Supply only Relay assembly for water cooler of 60/120 and 60/150 litres capacity complete all as specified.
Supply only Over Load Protector suitable for water coolers of any capacities complete all as specified. Make: TECUMESH/ARAVIND/KIRLOSKAR
Supply only Fan Motor Blade for the water cooler of any capacity complete all as specified.
Supply only Fan Motor for the water cooler of any capacity complete all as specified. Make: AUE/GE MARATON/ASHU
Flushing out the complete refrigerant system, supply and charging R-22 refrigerant gas including replacement of capillary tube and ‘U’ foam with new ones, cutting, brazing, leak detection and rectification in the entire system and commissioning the water cooler of 40/80, 60/120, & 60/150 litres capacity complete all as specified and directed.
Supply only brass chromium plated Push/Lifting Cock 15mm bore for the water cooler complete all as specified. Make: Jayson/HMP/Viking
Supply only Thermostat switch including knob plate for water cooler of any capacity complete all as specified. Make: INDOFOSS/RANUTROL/ANNPURNA
Taking out the unserviceable fan motor of water coolers of any capacity by disconnecting all electrical connections, opening the same and rewinding the burnt out motor with super enamelled copper wire duly insulated including replacement of bushes, mounting rubbers etc., with new ones, reassembling, reconnecting and testing complete all as specified and directed.
Supply only 15mm bore Ball brass valves, high pressure, with polythene float and fly nut complete all as specified.
Supply only 15mm bore PVC connection heavy duty with brass nuts, 600mm length, for water coolers complete all as specified.
Taking down the water coolers of 40/80 litres capacity by disconnecting all connections, cleaning all the components, denting and painting the outer exposed surfaces of cooler unit with one coat of synthetic enamel paint with spray gun and connecting up the cooler complete all as specified and directed.
All as per item No 41 above but water cooler of 120/150 litres capacity.
Supply only Fan Motor 1/7 HP for the evaporative desert cooler of capacity of 3000~4000 Cum/Hour complete all as specified. Make: Khaitan / Crompton Greaves / Usha / Almonard
Supply only Water Pump, 230 Volts, 50Hz, 1/66 HP for the evaporative desert cooler of capacity 3000~4000 Cum/hour complete all as specified. Make: Khaitan / Crompton Greaves / Usha / Coolhome
Supply only Khus Khus pads for the evaporative desert cooler of any capacity complete all as specified.
Cutting and removal of the damaged/leaking water tank portion of the evaporative desert cooler of capacity 3000~4000 Cum/Hour, supply, fabricate water tanks of same capacity, size and gauge out of galvanized iron sheet including necessary welding etc., and painting the outer surfaces of the entire desert cooler body with one coat of synthetic enamel paint with spray gun and connecting up the cooler complete all as specified and directed.
Supply only front grill for the evaporative desert cooler of capacity 3000~4000 Cum/Hour to match with the existing complete all as specified.
Servicing of the outdoor unit of split AC of any capacity by disconnecting all electrical connections, cleaning components i.e. condenser coil and evaporating coil by air blower to remove the dust and dirt and cleaning with caustic soda, reconnecting and testing complete all as specified and directed.
Supply only Potential relay for the split type air conditioner of 2 Ton capacity complete all as specified.
Supply only Potential relay for the split type air conditioner of 1.5 Ton capacity complete all as specified. Make for item No 50 & 51: Kirloskar / Tecumesh or equivalent as approved by GE
Supply only metallic fan blade for condensor motor of split type air conditioners of 1.5/2 Ton capacity complete all as specified.
Supply only 2 pole contactor AC3 rating of 12Amps for split type AC complete all as specified. Make: L&T CAT No CS90234 or equivalent in Legrand / Siemens / ABB / Schneider
S&F in repairs, single pole and neutral enclosure with a two pin and earth plug & socket complete with and including one single pole MCB SP 32 Amps 10KA, 240 Volts complete all as specified. Make: L&T / Siemens / ABB / Legrand / Schneider/C&S
Disconnecting electrically burnt out condensor motor of split AC, dismounting from existing position, over hauling, re-winding with super enamelled copper wire duly insulated, varnishing, replacing the worn out bearings, greasing and fixing back in original position, connecting up and commissioning complete all as specified and directed. Note: Labour required for dismounting and refxing back for the job shall be done by outsourcing persons employed under Sl item No 1 to 3 above
Leak testing of complete gas circulating system with dry nitrogen, flushing out complete system, vaccumising, supplying and charging the R-22 refrigerant gas including replacement of unserviceable of copper filter, capillary tube, ‘U’ foam etc., with new ones, cutting brazing, leak detection and rectification etc. for the split type Air Conditioner of 1.5/2 Ton capacity complete all as directed. Note: Nitrogen shall be arranged by the contractor
Supply only Air Filter indigenous washable type suitable for split type air conditioners of 1.5/2Ton capacity complete all as specified. Make: Porolator/Airtech/Kirloskar/Airfiko
Supply only Balanced Centrifugal Blower for the split type air conditioners of 1.5/2 Ton capacity complete all as specified. Make: ACRO/Blue star/Accel/Ventura/ACCB
Supply only evaporating coil made out of 25guage copper tubing having 30/34 gauge Copper fin 4.5cm length for split type AC of 1.5/2 Ton capacity complete all as specified. Make: Coil Co India/Blue Star/Jaypee/Voltas
Supply only copper condenser coil for split type AC of 1.5/2Ton capacity complete all as specified . Make: Coil Co India/Blue Star/Jaypee/Voltas
S&F in repairs Indoor Unit with all accessories suitable for 1.5/2 ton capacity Split AC including cutting, brazing, leak testing, reconnecting and testing complete all as specified and directed. Make: Crompton Greaves/Voltas/Blue Star/Carrier
Disconnecting the electrical connections, pumping down complete system, and removing the split type AC of 1.5/2 ton capacity including copper pipe from the existing position and shifting the same to the new location, re-connecting the AC after making suitable hole in the wall, flushing out the complete system, pressure testing the complete system with nitrogen after fixing, vaccumising topping up refrigerant gas to obtain designed cooling closing of suction and discharge valves, providing necessary connections, including closing the hole with cement mortar and finishing surfaces to match with the existing complete all as specified and directed.
Supply only Copper pipe of size 1/4" including tubular heat/cold resistant rubber / foam type insulation complete all as specified.
All as per Sl Item No 63 above but of size 3/8''.
All as per Sl Item No 63 above but of size 1/2''.
All as per Sl Item No 63 above but of size 5/8''.
All as per Sl Item No 63 above but of size 3/4''.
Taking down the unserviceable printed circuit board (PCB) of 1.5/2/3 (2 x 1.5) Ton capacity split AC by disconnecting all electrical connections, repairing the same and connecting up, testing and commissioning complete all as specified and directed.
Supply only Printed Circuit Board (PCB) with remote set suitable for 1.5/2/3 (2 x 1.5) Ton capacity split AC complete all as specified. Make: Voltas/Carrier/Blue Star/LG/Hitachi
Supply only Indoor unit swing motor for 1.5/2/3 (2 x 1.5 split) Ton capacity split type AC complete all as specified.
Supply only Indoor blower fan motor for 1.5/2/3 (2 x 1.5 split) Ton capacity split type AC complete all as specified. Make: Voltas/Carrier/Blue Star/LG/Hitachi
Supply only Refrigerant gas R-22
Supply only Refrigerant gas R- 410 A
Supply only Refrigerant gas R-134 A
Supply only PVC flexible drain pipe of 3/4'' dia complete all as specified.
Supply only outdoor unit stand made out of 19SWG mild steel powder coated sheet complete all as specified.
Supply only outdoor unit brass valve of size 1/4"/3/8"/5/8" complete all as specified.
Supply only remote hand set suitable for split type AC with batteries complete all as specified. Make: LG/Hitachi/Bluestar/Voltas
Universal refrigeration and Engineering Company
CHITRA ENGINEERING CORPORATION
Indu Electricals
vvcenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .