| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC RAILWAY COLONY DHANPURI | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹39.8 L+₹4,091 (0.10%)Rejected-Finance MISSION HOSPITAL CHOWK KEDARPUR AMBIKAPUR DIST SURGUJA CG 497001 | SURGUJA | CHHATTISGARH | 497001 | L2 | Rejected-Finance Rejected being L-2 bidder | |
| 3 | L3₹42.4 L+₹2.6 L (6.55%)Rejected-Finance 3 KANHA HERITAGE RING ROAD 2 BILASPUR CHHATTISGARH 495001 | BILASPUR | BILASPUR | CHHATTISGARH | 495001 | L3 | Rejected-Finance Rejected being L-3 bidder | |
| 4 | L4₹48.4 L+₹8.6 L (21.5%)Rejected-Finance ETTA BHATTA MAINROAD SURAJPUR BHATGAON SURAJPUR CHHATTISGARH | DURG | CHHATTISGARH | 490001 | L4 | Rejected-Finance Rejected being L-4 bidder | |
| 5 | L5₹49.0 L+₹9.2 L (23.2%)Rejected-Finance WARD NO 15 STATION ROAD SAKTI DISTT JANJGIR CHAMPA C G 495689 | SAKTI | JANJGIR CHAMPA | CHHATTISGARH | 495689 | L5 | Rejected-Finance Rejected being L-5 bidder |
Tender Value
₹72.1 L
EMD Value
₹90,200
Closing Date
25 Apr 2025, 5:00 pmClosed
SO EnM, SECL Raigarh Area
Office of the General Manager SECL Raigarh Area, Chhote Atarmuda Raigarh 496001
Day to Day Erection, reorganization, Dismantling, Shifting of 6.6KV and 3.3 KV HT Overhead line HT Cable at Chhal OCM for a period of 01 year (365 days) at Chhal OCM SECL Raigarh Area .
2025_SECL_333711_1
SECL/GM/RGH/EnM/e-Tender/ 25-26/ 01 dtd. 03/04/2025
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Raigarh Area
Please refer Tender documents.
6 documents required · 6 mandatory
₹90,200
24 May 2025
4 Apr 2025
28 Apr 2025
4 Apr 2025
25 Apr 2025
5 Apr 2025
4 Apr 2025 - 14 Apr 2025
Amount
NOTE : (i)Only Electric Poles & conductor will be provided by SECL . (ii)Arrangement of Hydra/ Crane (if required) for pole erection work will be responsibility of contractor
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. (Above 12 meter height & upto 16 meter height )
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc. as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp,bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc as required .
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc. as required .
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of upto 11 kV grade of following size in the existing masonry open duct as required : upto 120 sq. mm (For HT Cu Cable)
Erection/ Stringing of ACSR Dog Conductor including binding etc. as required
Erection/ Stringing of ACSR Rabbit Conductor including binding etc. as required for Running conductor
Transportation of new /old electric HT poles within mine boundary / switchyard /workshop (departmental veh. will be provided by SECL)
Supply of 8 SWG GI Wire for running earth and pole earthing
Erection of G.I. Wire No. 8 SWG including binding etc. as required for running earth and pole earthing etc.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, upto 11 KV overhead lines with rated voltage 6 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supply & Erection of Carpar Cradel Guarding with required GI wire , 1.5 meter angle bracket , clamp nut bolts & binding etc.
Tree branch cutting , bush cutting , cleaning & clearing site suitable for HT OHL installation at any place within mine boundary for a period of 01 year as per instruction of Engineer In Charge
Painting of HT pole upto height of 10 meter above ground & Numbering of pole
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply & fixing of Barbered wire anti climbing arrangement at each pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Shifting , erection & commissioning of 25 / 63/ 100 KVA Transformer on existing strucutre including Bi-metallic Clamp , ACSR/AAAC conductor i/c colour code sleeve for connection form HT line to Transformer as required
Supply installtion testing commissioing of DO fuse assembly with brass part contact for 11KV DP strucutre set of 03 nos. with fuse barrel i/c required fuse element & other material as per specification on exisitng DP structure as required
Supply and fixing of AB switch 800 Amps on Overhead 11 KV grade with GI connecting pipe , rods , clamps etc.
Total impact of GST for the purpose of CTC
MS R.P. JAISWAL (BID ID -1149657)
POWERTEK INDIA (BID ID -1150240)
M/S UMASHREE ENGINEERING (BID ID -1149983)
RAMESH KUMAR SWARNKAR (BID ID -1149511)
Azhar Enterprises (BID ID -1150438)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .