Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC 107 1A TOLLYGAUNG ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹53.8 L+₹6.8 L (14.5%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹55.5 L+₹8.6 L (18.2%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
10 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO ROOF OF BLDG NO O-18 AT AOI AND ADDN/ALTN TO OFFICE ROOM IN BLDG NO BI-17 AT ADV HQ EAC INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA.
2023_MES_580510_1
8987/FW/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender Documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹83,000
29 Mar 2023
11 Feb 2023
11 Mar 2023
11 Feb 2023
10 Mar 2023
24 Feb 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 150 mm thickness (above or below groud level) including removal of debris & rubbish from site complete all as specified and directed.
Demolition of cement concrete (reinforced) of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, all as specified and as directed by the Engineer-in-Charge.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key, scrubbing down with water etc. all as specified and directed.
Dismantling structural steel or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for RCC 1:1½:3 type A1 (using 20 mm graded stone aggregate)as in slabs supported on walls, beams and columns in floors, roofs, drain, ducts, canopies etc. complete all as specified and as directed.
Use and waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed .
M&L TMT Bars 6-8 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups , spacers and binders cut to length , bent to shape required as in reinforcement and binding with MS wire ( annealed ) not less than 0.90 mm dia complete all as specified and directed .
M & L for brick work using old size fly-ash bricks straight or curved on plan exec 6 metre mean radius, built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work using old size fly-ash bricks straight or curved on plan to any radius in half brick wall, built in cement mortar 1:4 complete all as specified and directed.
M & L for 20 mm thick plastering in two layers, 10 mm + 10 mm in cement mortar 1:4, top layer of 10 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
Supply only liquid water proofing compound all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished rendering surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished rendering surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for Providing, cement concrete, type B-1, 1:2:4 (using 20 mm graded Stone aggregate), as in flooring, benching to drain, coping etc and the like, edge slightly rounded or chanfered including necessary formwork complete all as specified and directed.
M&L for 25 mm thick plain cement concrete (1:2:4) type B-1 (using 12.50mm graded stone aggregate) as in sub base of floors etc, finished evan and fair complete all as specified and directed.
S&F Vitrified coloured (Dark shade) Ceramic tiles, 10 mm thick (square/rectangular) polished, area of each tiles exceeding 1.00 Sqm but not exc 2.00 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including screed bed 20mm thick in cement mortar 1:6 complete all as specified and directed.
All as per item No.19 above, but in skirting on vertical surfaces over and including rendering 10 mm thick in cement mortar 1:3 complete all as specified and directed.
S&F non-skid ceramic coloured tiles (square/ rectangular), 7 to 8 mm thick, area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, as per approved design, set and jointed in neat cement slurry in floors and pointed in white or coloured cement to match the shade of tiles, laid over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and directed.
All as per item No.21 above, but in skirting on vertical surfaces over and including rendering 10 mm thick in cement mortar 1:3 complete all as specified and directed.
S&F non-skid ceramic coloured tiles (square/ rectangular), 7 to 8 mm thick, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as per approved design, set and jointed in neat cement slurry in floors and pointed in white or coloured cement to match the shade of tiles, laid over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and directed.
S&F glazed coloured ceramic tiles in vertical surface, as per approved design, size 300 X 450 X 7 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, laid over and incl 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed.
M&L for granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, urinal partition and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and making moulds on edges laid over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Taking down wooden chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each complete all as specified and directed.
S&F Factory made solid PVC door frame (chowkhat) of size 100 mm x 45mm made out of 5mm plain colour PVC sheet, frame reinforced with MS square tube of size 40mm x 20mm of 19 guage throughout the frame, fixed in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
S&F for Factory made solid PVC moulded door shutter, 28 to 30 m thick(stiles) with 2,4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face with particle board core complete all as specified and directed.
Supply & fixing 100 mm stainless steel butt hinges (medium weight) cold rolled complete all as specified and directed.
S&F 150 mm long aluminium anodised handles (cast type) ISI marked complete all as specified and directed.
S&F 150 mm long aluminium anodised barrel tower bolts extruded section, ISI marked complete all as specified and directed.
S&F 300mm long aluminium anodised sliding bolt with hasp, staple (bolt type) and fixing clips or sheets cast of extruded section and fixing bolts and sliding bolts of extruded section ISI marked complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring (overall length of cover plate 150mm) complete all as specified and directed.
S&F Brass skelton tower bolts of length 200mm with cast brass plate and staples and rolled or drawn brass bolt and fixed, complete all as specified and directed.
S&F Floor door stopper of Brass body, polished with rubber cap fixed to door shutters with screws, complete all as specified and directed.
S&F Brass decorative handles 150mm size fixed, complete all as specified and directed.
S&F Heavy weight Brass decorative/moulded finished sliding bolt of 300mm long with hasp and staple (bolt type) fixing cleat of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded cast brass alloy, complete all as specified and directed.
S&F 4.0 mm plain sheet glass ordinary quality in steel or wooden frame with putty/beads in square n. exc 0.5 SQM in each pane complete all as specifed and directed
S&F 4.0 mm Frosted sheet glass ordinary quality in steel or wooden frame with putty/beads in square n. exc 0.5 SQM in each pane complete all as specifed and directed
Dismantling of wall board as in lining, panelling etc, of any gauge or any thickness including cover fillets complete all as specified and directed.
S&F PVC fillets of width 35 mm, made of 5 mm thick PVC sheet, for wall panelling inclusive of fixing as in grid / frame on wall at a distance 0.6m horizontal & vertical for wall lining/panelling as per specification of manufacturer and as directed by the Engineer-in-Charge.
S&F PVC solid wall lining consisting of 5 mm thick plain colour PVC sheet used inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction) complete all as specified and directed.
S&F stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F for Providing and fixing factory made uPVC white colour casement / sliding window / door, made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware, EPDM gasket, 1.2 + 0.2.mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, all complete and as directed, (Glazing, hardware hinges and fitting, EPDM rubber gasket etc. to be paid separately.) Note: Each member of window to be measured separately wrth clear length, Complete all as specified and directed.
Dismantling of AC corrugated or semi corrugated sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No.47 above, but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for brushing neat cement slurry with 2.75 Kg of cement per Sqm on roof complete all as specified and directed.
M&L for Providing Cement Concrete, 25 mm thick, type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding mixed with water proofing compound and the concrete surfaces is to be finished even and fair (without using extra cement) complete all as directed by Engineer - in - charge. (NOTE: WPC Shall be measured & paid separately)
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 1.2 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.20 litre per sqm over APP membrane.
Supply only liquid Water Proofing Compound, conforming to IS and as approved, complete all as specified.
M&L False ceiling with 'E' board "Classic", reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long and applying two coats of oil bound distemper over a coat of primer on exposed surfaces including dismantling of existing ceiling complete all as specified and as directed. (NOTE: Quoted rate shall be deemed to be inclusive of the cost of ceiling board)
M&L for structural steel work Fe 410-W (Gde-E-250) quality-A in roof trusses (framed), trussed, purlins, crane gantries, rials and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed by the Engineer-in-Charge. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to FE-410-W (Gde E-250) complete all as specified and directed.
Dismantling of ceiling board alongwith snap grid frame of any thickness complete all as specified and directed.
S&F Suspended metal grid Ceiling System with mineral fibre acoustic tiles as per following specifications:- a) Ceiling Tiles:- Mineral fibre acoustic tile of 16mm thickness having sand textured finish with acoustical punchers, bevelled tegular edge and 8mm drop in module size of 600 x 600mm. Tiles shall have humidity reistance (RH) of 99%, NRC 0.50 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84. b) Metal Grid:- The grid system shall be 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”.
(Item No. 59 Contd....) (c) All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The ceiling grid sections shall be fixed to ceiling with 6 mm dia GI hangers upto required length by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long. MAKE OF CEILING GRID : ARMSTRONG, Model: SUPRAFINE 38 or equivalent in GYPROC / USG BORAL / UNISTEEL MAKE OF CEILING TILES: ARMSTRONG, Model: DUNE or equivalent item in GYPROC / USG BORAL / U TONE)
S&F galvanised steel tubing, 50 mm bore, light grade, with all fittings, fixed in ceilings for hanging false ceiling including cutting holes into or through brick walls of 150 mm depth, built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregates) as required for superficial area exc 150sqcm but not exc 400 sqcm complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying 1.5 mm thick wall putty over plastered surfaces, finishing surfaces even and smoooth and applying two coats of acrylic distemper over a coat of alkali resistant primer with rollers as per manufacturer's instructions complete all as specified and directed.
M&L for complete removal of old treatment on walls and applying 1.5 mm thick wall putty over plastered surfaces, finishing surfaces even and smoooth and applying two coats of acrylic distemper over a coat of alkali resistant primer with rollers as per manufacturer's instructions complete all as specified and directed.
M&L for applying two coat of exterior acrylic emulsion weather proof paint over a coat of suitable exterior primer (as per manufacturer's instructions) after applying 2 mm thick wall putty to newly plastered surfaces of walls of any description, over 10cm width or girth not otherwise described, including preparation of surfaces complete all as specified and directed.
M&L for removal of existing treatment on walls and applying two coat of exterior acrylic emulsion weather proof paint over a coat of suitable exterior primer (as per manufacturer's instructions) after applying 2 mm thick wall putty to newly plastered surfaces of walls of any description, over 10cm width or girth not otherwise described, complete all as specified and directed.
M&L for preparation of old painted wooden surface of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted steel and iron surfaces of any description, exc 10cm in width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description, exc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed.
Taking up or down GI Steel Water Tubing including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed for the following size of pipes :-
15mm bore outer dia
20mm bore outer dia
25mm bore outer dia
Supply, Laying and testing Steel Water Tubing, Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and directed for the follwing size of pipes :-
15mm bore outer dia
20mm bore outer dia
Relaying/Re-fixing Galvanised Steel Tubing and Connections in New or Old Position (Serviceable Pipes and Fittings obtained from taking down item) after Cleaning both Inner and Outer Surfaces of Pipes by using of Wire Brush, fixed to walls and ceilings or laid in floors complete all as specified and as directed for the follwing size of pipes :-
15mm bore outer dia
20mm bore outer dia
Supply, laying and testing of 3- layer PP-R Polypropylene random copolymer) pipes SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed by Engr-in-Chargefor the following sizes:-.
15mm bore outer dia
20mm bore outer dia
S&F in repair vitreous china floor mounted rimless one piece closet (Pedestal pattern), white, including low level vitreous china valveless syphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, UF soft close seat cover and connecting fittings complete all as specified and directed. (Make : JAQUAR, Cat No: OPS-WHT-15853S300UF / PARRYWARE, Model: Omega / HINDWARE, Model: SPELNDOUR)
S&F in repairs Vitreous china floor mounted coupled closet (Pedestal pattern) coloured including low level vitreous china valveless syphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, PVC coloured seat cover and connecting fittings including taking down existing water closet complete all as specified and directed. (Make : PARRYWARE, Model : Cascade NXT / CERA, Model : CLAIR / HINDWARE, Model: CONSTELLATION or equivalent model in JAQUAR)
S&F in repair Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, making good disturbed Surfaces in Cement Mortar 1:3 including taking down/out unserviceable Wash Hand Basin and connected Items, complete all as specified and directed. (MAKE : PARRYWARE, Cat No. C0406 / HINDWARE, Cat No. 10010 / JAQUAR, Cat No. CNS-WHT-801 / CERA, Cat No: S2040141 / SOMANY, Model: SIGNATURE)
S&F vitreous china (White) Urinal concealed mounted sensor (new model) including all necessary fixing arrangement, in repairs, complete all as specified and directed. (Make : ESSESS Model No. URS-24-M or equivalent model in PARRYWARE, JAQUAR, CERA
S&F in repair 6mm thick bevelled edge mirror of size as required fixed on 6mm thick of size n.exc 1 Sqm acrylic sheet board backing, fixed with chrpmium plated screws and cup washer complete all as specified and directed.
S&F in repair CP bottle trap with internal portion 32mm size with 190mm long wall connection pipe complete all as specified and directed (Make: JAQUAR, Cat No: ALD-769L250x190 / ESS ESS, Cat No: C-231C / HINDWARE, Cat No: F850003 / CERA, Cat No: F8060302/ PRAYAG, cat No: BEA-26)
S&F in repair Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: KUP-35053PM / PARRYWARE, Cat No: T3097A1 / CERA, Cat No: F1005201 / PRAYAG, Cat No: 9410 / HINDWARE, Cat No: 320006 )
S&F Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore of Iron pipe, as in repairs, complete all as specified and directed. (Make : JAQUAR, Cat No: CON-59KN / PARRYWARE, Cat No: G1453A1 / ESS ESS, Cat No: C-206 / CERA, Model: OCEAN / PRAYAG, Cat No: 9210 / HINDWARE, Cat No: F330043)
S&F in repair, 15 mm bore fancy type stop valves, cast copper alloy, chromium plated (concealed type), screwed down, high pressure, with crutch or butterfly handle, incl concealed body, screwed both ends for iron pipe or for unions and, complete all as specified and directed. (MAKE : ESS ESS, Cat No: TM-332 & E221 / CERA, Model: F200351 & F4050102 /JAQUAR, Cat No: FLR-5083NK & ALD-083 / PARRYWARE, Cat No : G0651A1 & G5052A1 / / PRAYAG, Cat No: 9318 & CPS-15/ HINDWARE, Cat No: F280027 & F850096)
S&F in repair Chromium plated brass Bib cock with wall flange (premium quality), fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: FUS-29037 / CERA, Cat No: F1015151/ ASIAN PAINTS, Cat No: ALBC101 / PRAYAG, Cat No: 9306-N/HINDWARE, CAT No: F360004 or equivalent model in PARRYWARE)
S&F Chromium plated brass Bib cock with wall flange, long body, fixed to 15 mm bore of Iron pipe, as in repairs, complete all as specified and directed. (Make : Ess Ess, Cat No: TM-102 / CERA, Cat No: F2003151 / JAQUAR, Cat No: FLR-5047N/ PARRYWARE, Cat No: G0604A1 / / PRAYAG, Cat No: 9306 /HINDWARE, Cat No: F280002SCP)
S&F 15mm bore chromium plated two-in-one bib cock with flange, fancy type, as in repairs, complete all as specified and as directed. (Make : Ess Ess, Cat No: V-303 / JAQUAR, Cat No: QQT-7041/ PARRYWARE, Cat No: G1434A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9212/HINDWARE, CAT No: F330004CP)
S&F Tubular towel rail, 20mm dia, 600 mm long between flanges including brass chromium plated, complete all as specified and directed. (MAKE : ESSCO, Cat No : AEC-1111 / PRAYAG, Cat No : BA-10 / SOMANY, Model: ETHER / JAINKO, Cat No: TRJ-2)
S&F 15mm chromium plated Hand shower (health faucet), brass body with 1.2 metre long flexible tube in chrome finish with wall hook, as in repairs, complete all as specified and directed. (MAKE : JAQUAR, Cat No : ALD-573/ PARRYWARE, Cat No : T9941A1 / ESS ESS, Cat No: C-232D / CERA, Cat No: F8030401AB / HINDWARE, Cat No: F160002)
S&F Chromium plated brass Pillar tap, as in repairs etc. complete all as specified and as directed. (Make : JAQUAR, Cat No: QQT-7011 /EssEss Cat No. V-301, PRAYAG, Cat No: 9202 SOMANY, Model: ETHER / JAINKO, Cat No: AVJ-1)
S&F in repairs toilet paper holder, surface type with flap incl taking down existing holder complete all as specified and directed. (Make : JAQUAR, Cat No : AKP-35751P / PRAYAG, Cat No: BA-18 / ESS ESS, Cat No: AC-106 / CERA, Cat No: F5007110 /HINDWARE, Cat No: F880003)
S&F in repairs chromium plated brass jet spray with one metre PVC tube including taking existing jet spray complete all as specified and as directed . (Make : Essco, Cat No ALE-547/PRAYAG, Cat No: BEA-17 or equivalent model in SOMANY/ JAINKO)
S&F chromium plated brass fancy type soap dish, as in repairs, complete all as specified and directed. (Make : Jaquar, Cat No : AKP-35731P / PARRYWARE, Cat No: T6403A1 / ESS ESS, Cat No: AC-503B / PRAYAG, Cat No: BA-35 or equivalent model in CERA /HINDWARE)
S&F Chromium Plated glass shelf of size 460mm x130mm fixed to wall with Chromium Plated screws as in repair, complete all as specified and as directed. (Make : Ess Ess, Cat No: AC-207 / JAQUAR, cat No: AQN-7771 / PARRYWARE, Cat No: T6009A1 or equivalent model in PRAYAG / HINDWARE / CERA).
S&F in repair PTMT shelf, 450 mm long complete all as specified and directed. (Make : PRAYAG, Cat No : 191 or equivalent make as approved by GE).
S&F in repair PTMT shelf, 600 mm long complete all as specified and directed. (Make : PRAYAG, Cat No : 192 or equivalent make as approved by GE).
S&F in repair 32 mm bore PVC corrugated waste pipe, 800 mm long for wash hand basins complete all as specified and directed. (Make: PRAYAG, Cat No: 327 or equivalent make as spproved by GE)
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
Supply and fixing 110mm bore PVC (SWR) pipes, single socketed, in any length, with rubber ring joints, fixed to wall all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 75mm bore PVC (SWR) pipes, single socketed, in any length, with rubber ring joints, fixed to wall all as specified and as directed by the Engineer-in-Charge.
Supply and Fixing 110 mm PVC (SWR) Bend any radius complete all as specified and as directed by the Engineer-in-charge.
Supply and Fixing 75 mm PVC (SWR) Bend any radius complete all as specified and as directed by the Engineer-in-charge.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches of 100 mm internal dia complete all as specified and as directed.
S&F Cast iron (sand cast) soil, waste and vent pipes 100 mm bore of any length with or without ears with cement joints all as specified laid in trenches or in floors complete all as specified and directed.
Supply and fixing 100 mm bore cast iron (sand cast) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed on walls, complete all as specified and as directed.
S&F 100mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and directed.
S&F 100mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured) fitted with ovel access door, complete all as specified and directed.
S&F 100mm bore CI branch pieces single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed.
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly,. Complete all as specified and directed. for one light point / bell point/ceiling fan/exhaust fan point controlled by one way switch. (NOTE :- (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Point wiring shall be measured from switch board/DB to outlets only. Main circuit wire of the switch board/DB shall be measured and paid separately as sub main wiring of required size depending upon the load of that switch board. (iii) Quoted rate shall be exclusive of the cost of terminal box and laminate cover which shall be measured separately.
All as per item No 111 here-in-before, but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 111 here-in-before, but for one 5 pin 5/6 amps multi socket outlet point in independent board (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 111 here in before, but using 2.5 sqmm PVC insulated unsheathed multi strand copper cable (1100 V) FRLSH for line conductor and 1.5 Sqmm PVC insulated unsheathed multi strand FRLSH copper cable (1100 Volts) for earth continuity wire for one 15/16 amp multi socket out let independent (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
S&F Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S&F Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S&F Modular Socket 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S&F Modular Socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S&F Modular Blank plate 1 module, complete all as specified and directed.
S&F Modular Bell push 6A, 1 module, complete all as specified and directed.
S&F new Call bell, musical type, AC 230/240 Volts, Single Pole
S&F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 4 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S&F Modular White cover plate with frame 8 module complete all as specified and directed.
S&F Modular White cover plate with frame 12 module complete all as specified and directed.
S&F Modular type Metal Flush box 3 module complete all as specified and directed.
S&F Modular type Metal Flush box 4 module complete all as specified and directed.
S&F Modular type Metal Flush box 6 module complete all as specified and directed.
S&F Modular type Metal Flush box 8 module complete all as specified and directed.
S&F Modular type Metal Flush box 12 module complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/Bakelite, three terminals complete all as specified and directed.
M&L for sub main wiring with two run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm as earth continuity conductor drawn through and including PVC conduit of suitable size, surface type incl taking down existing wiring complete all as specified and directed. (NOTE : Three runs of single core 4.0 Sqmm cable & one run of PVC conduit shall be measured as one unit)
M&L for sub main wiring with four run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 Sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 Sqmm as earth continuity conductor drawn through and including PVC conduit of suitable size, surface type incl taking down existing wiring complete all as specified and directed. (NOTE : Four runs of single core 4.0 Sqmm cable & one run of PVC conduit shall be measured as one unit)
Supply and Hanging, ceiling fan, with brushless DC motor, 1200 mm sweep without remote, down rod, canopy, fan blades and accessories, BEE 5 Star rated and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.0 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan including dismantling existing fan complete all as specified and directed. (MAKE : USHA, Model: TECHNOAIR / CROMPTON GREAVES, Model : ENERGION HS / ORIENT, Model: ECOTECH or equivalent model in BAJAJ / HAVELLS) NOTE: Old fan shall be deposited by contractor in MES store yard
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate diffuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
All as per Item No. 137 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
S&F in repairs recess mounted slim-fit downlighter, round or square, having glare free frosted diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 15 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 105 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
S&F recess mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 35/36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium range), for mounting of MCB for 240 Volts, TPN 4 way, with 200 Amps rated copper bus bar, complete all as specified and directed. (MAKE : L&T / LEGRAND /ABB / SCHNEIDER / C&S /PANASONIC/ HAGER)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium range), for mounting of MCB for 240 Volts, SPN 8 way, with 100 Amps rated copper bus bar, complete all as specified and directed. (MAKE : L&T / LEGRAND /ABB / SCHNEIDER / C&S / PANASONIC / HAGER)
NOTE FOR ITEM NO.144 & 145 :- (1) Incoming MCB and outgoing MCBs shall be measured and paid separately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB & MCB shall be of the same manufacturer.
S&F MCB (premium range), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / C&S / PANASONIC / HAGER)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / C&S / PANASONIC / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / C&S / PANASONIC / HAGER)
S&F exhaust fan 300 mm sweep, 900 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 sqmm (nominal area) from ceiling rose to fan complete all as spcified and directed. (MAKE : HAVELLS, Model: Turbojet SP / CROMPTON, Model: EXHD300-6-1 / USHA, Model: Turbo Heavy Duty or equivalent model in BAJAJ / ORIENT) NOTE: Old fan, if any taken down, shall be deposited by contractor in MES storeyard.
S&F wall mounted fan 450 mm sweep, 1400 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, louvers complete with all accessories and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.0 Sqmm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan, complete all as specified and directed. (MAKE : HAVELLS, Model: Airboll Hi-Speed / ORIENT, Model :Tornado-wall II / or equivalent model in CROMPTON / USHA / BAJAJ) NOTE: Old fan, if any taken down, shall be deposited by contractor in MES store yard.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., complete all as specified and directed. (MAKE : HAVELLS / CROMPTON / AO Smith SDS / BAJAJ)
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
RAJ ENTERPRISE
Tirupati Buildcon Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .