Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹29.0 L+₹55,298 (1.95%)Rejected-Finance 01 NEAR GOVERMENT HOSPITAL KOTHI BAZAR ROAD KOTHI SATNA MADHYA PRADESH 485666 | SATNA | MADHYA PRADESH | 485666 | L2 | Rejected-Finance not become lowest bidder | |
| 3 | L3₹29.4 L+₹1.0 L (3.66%)Rejected-Finance | L3 | Rejected-Finance not become lowest bidder | |
| 4 | L4₹30.1 L+₹1.7 L (5.97%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance not become lowest bidder | |
| 5 | L5₹32.1 L+₹3.7 L (13.0%)Rejected-Finance | L5 | Rejected-Finance not become lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 May 2025, 6:00 pmClosed
Major Sunny Kumar Attri
Garrison Engineer Jhansi
REPAIR / CLEANING OF SEWAGE LINE, SEPTIC TANK, MANHOLE AND CONNECTED ITEMS FOR ZONE C AREA UNDER AGE B/R-I AT GE JHANSI
2025_MES_706665_1
GE/JHA/TOK/44 OF 2025-26
Open Tender
Civil Works
Item Rate
330 days
GE Jhansi
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Jhansi
₹80,000
Yes
1 Aug 2025
3 May 2025
2 Jun 2025
3 May 2025
30 May 2025
17 May 2025
3 May 2025 - 16 May 2025
Amount
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in any type of soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 M wide and exceeding 1.5m but not exceeding 3 M depth for foundation, etc., and getting out in any type of soil complete all as specified and directed.
Excavation over area not exceeding 1.5 M in depth and getting out in any type of soil complete all as specified and directed.
Excavation over area exc. 1.5m but not exceeding 3.0 M in depth and getting out in any type of soil complete all as specified and directed.
Excavation over area exc. 3.0 m but not exceeding 4.5 M in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
M&L for laying and testing of 100 mm dia SGSW (Salt glazed stoneware) drain pipe grade ‘A’ (ISI Marked) laid in trenches to level /gradient, jointed in CM 1:1 complete including demolition and breaking up old drain pipes (Salt glazed stone ware, AC or reinforced cement concrete) set in cement mortar including concrete bed complete all as specified and directed
M&L for laying and testing of 150 mm dia DWCPE (SN8) pipes incl vollor laid and jointed in cement mortar and tested on completion and make the line functional, including demolition and breaking up old drain pipes (Salt glazed stone ware, AC or reinforced cement concrete) set in cement mortar including concrete bed complete all as specified and directed
M&L for laying and testing of 250 mm dia DWCPE (SN8) pipes incl vollor laid and jointed in cement mortar and tested on completion and make the line functional, including demolition and breaking up old drain pipes (Salt glazed stone ware, AC or reinforced cement concrete) set in cement mortar including concrete bed complete all as specified and directed
M&L for 1:3:6 type C-2 concrete bed to drain pipe including packing under and haunching against the side of pipe after they are laid and tested of 100mm bore complete all as specifed and directed.
M&L for 1:3:6 type C-2 concrete bed to drain pipe including packing under and haunching against the side of pipe after they are laid and tested of 150mm bore complete all as specifed and directed.
M&L for 1:3:6 type C-2 concrete bed to drain pipe including packing under and haunching against the side of pipe after they are laid and tested of 250mm bore complete all as specifed and directed.
Cutting into existing manholes, bricks wall for connecting new drain pipe/bend/Tee of 100mm dia size and making good to pipe or wall leak proof and rendering cutting out existing benching for and forming branch channels (1/2 round or ¾ section) manholes and filling cut of walls by cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate smooth finish and reforming benching as required for 100mm internal dia of pipe complete all as directed by Engineer-in-Charge.
Cutting into existing manholes, bricks wall for connecting new drain pipe/bend/Tee of 150mm dia size and making good to pipe or wall leak proof and rendering cutting out existing benching for and forming branch channels (1/2 round or ¾ section) manholes and filling cut of walls by cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate smooth finish and reforming benching as required for 150mm internal dia of pipe complete all as directed by Engineer-in-Charge.
Cutting into existing manholes , bricks wall for connecting new drain pipe/bend/Tee of 250mm dia size and making good to pipe or wall leak proof and rendering cutting out existing benching for and forming branch channels (1/2 round or ¾ section) manholes and filling cut of walls by cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate smooth finish and reforming benching as required for 250mm internal dia of pipe complete all as directed by Engineer-in-Charge.
S & F in repairs 15 mm bore concealed type stop cock fancy type,chromium plated with long shank crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as directed by Engineer-in-Charge.
Attending day to day complaints of Cleaning of all blockage of any type of sewage line i.e. branch sewer line, main sewer line etc, manholes of any size and depth, in any situation by way of cleaning/desludging by manually or mechanically or by way of any other suitable means including foreign materials as well as rodding (full through) of sewer lines and between the blocked manholes where required and ordered by Engineer-in-charge and keeping the sewage line all time functional ,cleaning traps, water closet, soil waste/vent pipe, gully traps etc complete upto final drop into septic tanks and soakage well (working in foul condition with taking precautionary measures with necessary equipment as required or applicable by deploying 03 Nos of safaiwala for 08 hrs working complete all as directed by Engr-in-Charge. The sludge removed from the manholes and sewage line shall be removed to out side MoD land complete all as directed by Engr-in-Charge in entire Jhansi Cantt (entire OTM and entire Married accn) area under AGE B/R-I Jhansi. Note:- Each Job shall contain various complaints of sewage recieved by the office each day.
M&L for cleaning/desludging of existing septic tank/sokage well of any capacity and depth with inlet/outlet chambers including taking out sludge (both organic and inorganic matter) in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots or vegetation etc by means of sewage sucking machine and after plugging the incoming sewer line through combined high pressure water jetting/ suction (Vacuum) type machine mounted on LCV/HCV facility of high pressure vacuum and removing the sludge outside MOD land by any means and at a place meant for the purpose by local Municipality complete all as specified and directed. NOTE:- For measurement purpose, Liquid depth of septic tank shall be measured before removal of sludge.
M & L for puncturing existing SGSW/RCC pipe line of any dia at any places between manholes for cleaning blockage in pipes including necessary excavation in any type of soil, returning filling in and removal of soil and making good punctured area with CM (1:1) complete all as specified & directed
S&F 100mm bore cast iron (sand cast) soil waste and vent pipe (ISI Marked)in any length with or without ears with cement joint laid in trenches including taking out of existing pipes complete all as specified and directed.
S&F 100 mm bore CI bends (any radius) diminishing pieces or tapers (large bore measured) fixed in cement joints including taking out existing AC/cast iron bends complete all as specified and directed.
S&F 75mm bore cast iron (sand cast) soil waste and vent pipe (ISI Marked)in any length with or without ears with cement joint laid in trenches including taking out of existing pipes complete all as specified and directed.
S&F 75mm bore CI bends (any radius) diminishing pieces or tapers (large bore measured) fixed in cement joints including taking out existing AC/cast iron bends complete all as specified and directed.
S&F 100mm dia cast iron branch pieces single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with cement joint in 1:1 complete all as specified and directed.
All as per item No-25 herein before but 75mm bore
M&L for jointing only 100mm dia cast iron pipes and fitting or AC pipes and fittings with cement joints in repair complete all as specified and directed.
M&L for jointing only 75mm dia cast iron pipes and fitting or AC pipes and fittings with cement joints in repair complete all as specified and directed.
S&F in replacement PVC (SWR) multi floor trap 100mm dia of outlet without grating including jointing to waste pipe with solvent cement complete all as specified and directed.
S&F in replacement vitreous china squatting pan of Orissa pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including provision of concrete bedding complete all as specified and directed.
S&F in repair vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe) and P or S trap including connection to drain (or outgoing pipe) and to flushing pipe anti-syphonage pipe etc including plastic water closet seat, black closed pattern with flat bottom and cover and mild steel chromium plate or aluminised hinging device complete all as specified and directed
M&L for PCC 1:4:8 type D2 using 40mm graded stone agg as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with sub class 'B' bricks in one bricks thick honey comb built in cement mortar 1:4 complete incl demolitin of old brick work of any description complete all as specified and directed.
M&L for brick work with sub straight or curved on plan exc 6m mean radius, built in curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete incl demolitin of old brick work of any description complete all as specified and directed.
M&L 15 mm thick rendering in CM (1:4) on fair/uneven surfaces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed
M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed.
M & L Preparing of new plastered surfaces of walls and applying two coats of cement base paint over one coat of cement based primer complete all as specified and directed.
M&L for precast cement concrete (1: 2: 4) type B-1 using 20 mm graded stone aggregate as in drain/manhole covers, with plain fair faces including chamfers, weathering throating etc and set in cement mortar (1:4) complete with joint to match including necessary form works complete all as specified and directed.
M & L Mild steel deformed (TMT) 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
All as per serial item No-39 here in before but MS deformed (TMT) 6 to 8 mm dia.
M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in sub base etc, complete all as specified and directed by EIC.
M & L for Non- skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed/ bedding layer in CM (1:6) complete incl dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed.
M&L for ceramic colour tiles in vertical surface of size 450 X 300 x 7 mm thick, jointless type, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with over and including 10 mm thick rendering in CM (1:4) for receiving the tiles, complete incl dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed.
Supply and Fix in repairs 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long.flush pipe 32mm dia PVC complete all as directed by Engineer-in-Charge.
S & F in repairs 15 mm bore Bib taps long body fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair for Fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as directed.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste copling,including PTMT PVC connection 600mm complete all as specified and directed.
S & F in repairs 15 mm bore stop/angle cock fancy type,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trenches incl taking up or down old pipes complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trenches incl taking up or down old pipes complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal complete all as specified and directed.
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal complete all as specified and directed.
S & F PVC Floor trap of 75 mm outlet with grating including jointing to waste pipe in run lead complete all as specified and directed.
ADARSH ENTERPRISES (BID ID -3302445)
UNIVERSAL ENGG CO (BID ID -3308813)
M/S Kumar Contractors (BID ID -3309489)
M/s Sohanil Construction (BID ID -3303059)
HARNAM SINGH ANIL SINGH (BID ID -3309577)
m/s ramesh saran agarwal (BID ID -3308318)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .