Tender Value
Refer Docs
EMD Value
₹79,060
Closing Date
13 Mar 2023, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha road New Navy Nagar colaba mumbai
SPECIAL REPAIR REPLACEMENT OF SUBMAIN WIRING AT VARIOUS BUILDING AT OUTLAYING AREA COLABA MUMBAI
2023_MES_577916_2
8113
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹79,060
Yes
20 Mar 2023
16 Feb 2023
18 Mar 2023
16 Feb 2023
13 Mar 2023
1 Mar 2023
16 Feb 2023 - 28 Feb 2023
Amount
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping not less than 25mm width and 16mm depth, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping. Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Taking down old unserviceable submain wiring. Supply and fix in repair submain wiring two single core FRLS unsheathed 1100 volts grade cable of size 6 Sqmm for sub main wiring with stranded copper conductor multistranded PVC insulated and unsheathed 1100Volts grade in and including PVC casing capping ISI marked including 1 single core cable with stranded copper conductor of size 6 sqmm (green colour) for earthing. Note :- (i) Two runs of 06 Sqmm cable, one run of 6.0 Sqmm earth cable and one run of PVC conduit shall be measured as one running meter. (ii) Each submain wiring shall run in seperate PVC conduit Make of wire - Polycab / Finolex / Havells Make of conduit - Pressfit / Precision
Taking down old unserviceable submain wiring cable . Supply and fix submain wiring cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 3 core , 10 Sqmm and including laying , sadling with clamps, / laid in duct / along pole/wall tc including making connection to DB complete all as specified and directed by Engineer-in-Charge. Make of wire - Polycab / Finolex / Havells Make of conduit - Pressfit / Precision
Taking down old unserviceable DB . Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-54, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size and making good / match with old existing area complete all as directed by Engr-in- charge. Make - Legrand/ Schneider/ GE/Havells/ L & T/ ABB
Taking down old unserviceable MCB SPN. Supply and fixing MCB SPN 63 Amps, 240 Volts Make - Legrand/ Schneider/ GE/Havells/ L & T/ ABB
Taking down old unserviceable MCB SP. Supply and fixing MCB SP 6-32 Amps, 240 Volts. Make - Legrand/ Schneider/ GE/Havells/ L & T/ ABB
Taking down old unserviceable DB . Supply and fix in repair MCB, DB, SPN 8 way double door with protection type IP-54 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size and making good / match with old existing area complete all as directed, as approved comprising following :- Make - Legrand/ Schneider/ GE
Taking down old unserviceable MCB SPN. Supply and fixing MCB SPN 40 Amps 240 Volts. Make - Legrand/ Schneider/ GE/Havells/ L & T/ ABB
Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way and making good / match with old existing area comprising with following :- (a) MCB SPN 40Amps 240Volts, 10KA - 1 No ('C' Series) (b) MCB SP 6 - 32Amps 240Volts - 2No ('C' Series) Make - Legrand/ Schneider/ GE/Havells/ L & T/ ABB
Taking down old unserviceable DB . Supply and fix in repairs sheet metal enclosure 2 way without bus bar . Make - Legrand/ Schneider/ GE/Havells/ L & T/ ABB
Taking down old unserviceable MCCB enclosure . S & F of MCCB sheet metal enclosure including MCCB 4 Pole, 415 V of 200 amp capacity 25 KA with all accessories etc complete all as specified and directed by Engineer-in-Charge. Make - Legrand/ Schneider/ GE/Havells/ L & T/ ABB
Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type C2 and cast iron cover, watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No. 5 of SSR Pt-1, including testing on completion.
Supply and fixing GI strip 25mm x 4mm for building earthing and sadling in cable trunch, building cable duct from the LT panel to DB up to height of 39 RM from ground and fix properly all as directed by Engr-in-Charge
SHRI SAI ENTERPRISES
Ashish Enterprises
ORIENT ELECTRIC CO
NOEL ENGINEERS
ELECTRO ASSOCIATES
shubham construction
S S ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .