| 1 | L1₹51.0 LAccepted-AOC | L1 | Accepted-AOC QUOTED AMOUNT IS REASONABLE | |
| 2 | L2₹56.2 L+₹4.7 L (9.15%)Rejected-Finance PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹69.4 L+₹17.8 L (34.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹72.8 L+₹21.3 L (41.3%)Rejected-Finance WZ143 A 7 A S 4 43 GALI NO 2 OLD MAHABIR NAGAR NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹84.3 L+₹32.8 L (63.7%)Rejected-Finance C 204 NANGLI EXTN NEW DELHI | WEST | DELHI | 110043 | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | S GOURAV PRAKASH ENTERPRISES L5 | M/S TRIVENDRA KUMAR L3 | M/S Parmod Johar L2 | M/S Sunil Steel Works L4 | M/s SAAR ENGINEERS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for followings :-
(i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams
(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible from all sides)
(iii) Removal of cover concrete with under cutting of up to a depth of 10mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)
(iv) Cleaning exposed concrete substrate by using water jet.
(v) Removing visible rust along the length of reinforcement using hand tools as approved.
(The Engr-in-charge may order sand blasting if needed)
(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 2,455 | Sqm | 130 ₹3,19,150 | 50 ₹1,22,750 | 50 ₹1,22,750 | 120 ₹2,94,600 | 17 ₹41,735 Lowest |
| 2.00 | M&L for providing rust proof /anti corrosive treatment to bars :-
(i) cleaning of all exposed bars (new & old) alround
(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer
(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer.
Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re-bars (those towards the concrete substrate) should not be left without coating .Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 2,455 | Sqm | 120 ₹2,94,600 | 50 ₹1,22,750 Lowest | 100 ₹2,45,500 | 120 ₹2,94,600 | 55 ₹1,35,025 |
| 3.00 | M&L for providing PMM (Polymer modified cementitious mortar) :-
(i) Dry sub strate surface and free of debris & dust
(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).
(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) upto 50 mm thickness.
Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.
(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 2,455 | Sqm | 1,200 ₹29,46,000 | 650 ₹15,95,750 | 500 ₹12,27,500 | 1,000 ₹24,55,000 | 275 ₹6,75,125 Lowest |
| 4.00 | M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying 10 to 15 mm thick cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessary chased to brick work or RCC members at any height upto six storey buildings incl removing of small trees shrubs etc all as specified (Note: steel welded mesh to be welded with the existing reinforcement. The cost of welded mesh is to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 1,250 | Sqm | 998 ₹12,47,500 | 750 ₹9,37,500 Lowest | 800 ₹10,00,000 | 1,000 ₹12,50,000 | 888 ₹11,10,000 |
| 5.00 | M& L for fixing rebar of required length & diameter for structural connection in RCC slab, Beams and similar situations including power drilling holes of appropriate diameters in reinforced or plain concrete upto depth minimum 100 mm or as per manufacturers specification, fixing the reinforcement in position using epoxy Arcylate based anchoring adhesive at all heights and levels, 14 mm dia hole suitable for inserting 10 mm dia reinforcement bars all as specified & directed ..Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 25 | Each | 3,000 ₹75,000 | 800 ₹20,000 | 500 ₹12,500 | 200 ₹5,000 Lowest | 599 ₹14,975 |
| 6.00 | M& L for fixing rebar of required length & diameter for structural connection in RCC slab, Beams and similar situations including power drilling holes of appropriate diameters in reinforced or plain concrete upto depth minimum 100 mm or as per manufacturers specification, fixing the reinforcement in position using epoxy Arcylate based anchoring adhesive at all heights and levels, 12 mm dia hole suitable for inserting 08 mm dia reinforcement bars. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 25 | Each | 2,900 ₹72,500 | 850 ₹21,250 | 500 ₹12,500 | 180 ₹4,500 Lowest | 599 ₹14,975 |
| 7.00 | S&F TMT bars 5 mm dia upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with with mild steel wire (annealed) not less than 0.9mm dia or securing with clips including U-shaped stirrups with necessary welding required at site and all as directed by Engr-in-Charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 100 | Kg | 90 ₹9,000 Lowest | 120 ₹12,000 | 100 ₹10,000 | 100 ₹10,000 | 105 ₹10,500 |
| 8.00 | M&L for Providing & Pouring Micro concreting M-40 grade :-
(I) Dry concrete substrate surface and free of debris & dust
(ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).
(iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed including M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed.
Note : Form work shall be 100% leak proof. The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 2 | Cum | 1,10,000 ₹2,20,000 | 9,500 ₹19,000 Lowest | 50,000 ₹1,00,000 | 30,000 ₹60,000 | 19,999 ₹39,998 |
| 9.00 | M&L for 5mm thick rendering in cement mortar 1:3 finished even and smoothe surface without using extra cement on ceiling, chajja in double storey building etc incl taking down incl two coats of white wash complete all as specified and directed by Engineer-in-Charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 300 | Sqm | 250 ₹75,000 | 200 ₹60,000 | 200 ₹60,000 | 180 ₹54,000 Lowest | 235 ₹70,500 |
| 10.00 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed finished even and fair including taking down old plaster complete all as specified. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 4,000 | SQM | 170 ₹6,80,000 | 225 ₹9,00,000 | 150 ₹6,00,000 | 120 ₹4,80,000 Lowest | 150 ₹6,00,000 |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
26 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DELHI CANTT
HQ CWE DELHI CANTT-110010
REPAIR MAINT OF CHAJJA COLUMN BEAM WALL PLASTER IN MULTI STOREY BLDG IN ARJAN VIHAR PRATAP CHOWK AND OTHER ADJOINING AREA OF AGE B AND R II UNDER GE CENTRAL DELHI CANTT-10
2025_MES_727276_1
CWE/D-51/2025-26
Open Tender
Civil Works
Item Rate
120 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE CENTRAL DELHI CANTT
₹1.4 L
Yes
13 Dec 2025
22 Aug 2025
27 Sept 2025
22 Aug 2025
26 Sept 2025
12 Sept 2025
Amount
M&L for followings :- (i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible from all sides) (iii) Removal of cover concrete with under cutting of up to a depth of 10mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if needed) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re-bars (those towards the concrete substrate) should not be left without coating .Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) upto 50 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying 10 to 15 mm thick cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessary chased to brick work or RCC members at any height upto six storey buildings incl removing of small trees shrubs etc all as specified (Note: steel welded mesh to be welded with the existing reinforcement. The cost of welded mesh is to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M& L for fixing rebar of required length & diameter for structural connection in RCC slab, Beams and similar situations including power drilling holes of appropriate diameters in reinforced or plain concrete upto depth minimum 100 mm or as per manufacturers specification, fixing the reinforcement in position using epoxy Arcylate based anchoring adhesive at all heights and levels, 14 mm dia hole suitable for inserting 10 mm dia reinforcement bars all as specified & directed ..Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M& L for fixing rebar of required length & diameter for structural connection in RCC slab, Beams and similar situations including power drilling holes of appropriate diameters in reinforced or plain concrete upto depth minimum 100 mm or as per manufacturers specification, fixing the reinforcement in position using epoxy Arcylate based anchoring adhesive at all heights and levels, 12 mm dia hole suitable for inserting 08 mm dia reinforcement bars. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F TMT bars 5 mm dia upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with with mild steel wire (annealed) not less than 0.9mm dia or securing with clips including U-shaped stirrups with necessary welding required at site and all as directed by Engr-in-Charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L for Providing & Pouring Micro concreting M-40 grade :- (I) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed including M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar 1:3 finished even and smoothe surface without using extra cement on ceiling, chajja in double storey building etc incl taking down incl two coats of white wash complete all as specified and directed by Engineer-in-Charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed finished even and fair including taking down old plaster complete all as specified. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L Providing and applying cement base plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as directed.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L for preparation of New decorated plastered surfaces of walls/ ceiling providing and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of walls applying wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth to receive primer and applying one coat primer & two or more coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
Cutting shrubs wild growth, plants not exc 30 cm girth grown on permanent structures and removing same growth right from roots and stopping the recurrence by injecting herbicide Glyphosphate 4+ solution (04 % concentrate) into plant root to eliminate further growth. Application shall be as per manufactureres intructions. The disturbed area shall be repaired with PCC (1:2:4) Type B0 mix and surface finished even and smooth in cm 1:4 incl applying two coats of matching finish i.e. Building is not less than 50 nos . complete all as specified and directed at site Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) by using diamond saw blade cutting machine without damaging adjacent RCC structures not otherwise including removal of rubbish outside complex ( MOD land), complete all as specified. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F of min 4mm thick prefabricated Factory made FRP chajja of fibre ways brand or equivalent in required size, colour and design made by Resin Transfer Moulding (RTM) machine technology, resulting in voids free compact laminate in single piece having smooth gradual slope curvature of easy drainage of water fixed to wall having silicon sealant joint in between chajja and wall so as to prevent any leeage/seepage through joints complete all as specified and directed by Engr-in-charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F Roof trusses (framed), truss, framed brackets of angles, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel flat or hollow sections) including distance pieces, cleats etc. Fe 410-W(Gde E-250) quality-A complete all as specified and directed by Engineer-in-Charge
S&F Pre painted curved galvalum aluminium zinc coating GI based corrugated sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall ,fixed with self tapering screws as specified by Engineer in Charge.
M & L for painting previously untreated steel and iron surfaces of any description, over 10cm in width or girth,not otherwise described with one coats of synthetic enamel paint complete all as directed.
M&L for preparation of old decoreated/undecoreated external walls/ ceiling providing and finishing walls with Acrylic Smooth exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
Demolition and breaking up drain pipe salt glazed ware, AC, PVC/CI or reinforced concret pipes internal dia of pipe 100mm /75mm complete all as specified and directed by Engr-in- charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S & F 75 mm dia (bore of pipe) cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls and gap between wall and pipe will be filled by PCC 1:2:4 complete all as specified and directed by Engr-in- charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S & F 100 mm dia (bore of pipe) cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to wall sand pipe will be filled by PCC 1:2:4 complete all as specified and directed by Engr-in- charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F CI bend 75mm tee elbow socket complete all as specified and directed by Enr in charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F CI bend 100mm tee elbow socket complete all as specified and directed by Enr in charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F in repairs triple layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) of approved colour hoisted and jointed in position including dismantling of tanks all as specified in SSR Part-I of 1000 ltr capacity complete all as specified and directed by Engr-in-charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S & F in repairs of 20mm ball brass valve high pressure with polyethlene float flynut complet screwed with iron pipe or brass ferrule and fixed in repair all as spd.
S & F in repairs of 20mm bore Gun metal globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed all as specified and directed.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store of 20 mm bore.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
Taking up or down 15mm bore GI tubing and connections, including cleaning for re-fixing or removal to store, complete all as specified and directed.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F GI water tubing medium grade 20mm bore with all fittings and fixed complete to walls and ceiling or laid in floors Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F GI water tubing medium grade 15mm bore with all fittings and fixed complete to walls and ceiling or laid in floors Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
Complete removal of existing treatment on wall (any number of layers ) by scarping with steel scrapers or any other mean including filling depressions of scrapped surface with putty and preparation of surface for further treatment and M&L for two coats of distemper oil emulsion white or tinted complete all as specified and directed by Engr-in -Charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F in repair of Upvc pipe line (Sch-40) of 32 mm dia for AC drain fixed to wall with suitable fittings like elbo, tee etc and clamping with wall all as specified and directed by Engr-in-Charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
S&F in repair 150 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed complete to walls, ceilings or in floors with suitable clamps/bracket including taking down old PVC/CI pipes and necessary cutting through RCC roof and brick work etc (above six storey height) and making good all as specified.
S&F in repair of 150mm dia PVC (SWR) bends any radius with solvent joints, complete all as specified.
S&F in repair of 150mm dia PVC (SWR) TEE any radius with solvent joints, complete all as specified.
Cleaning and drying the brick surfaces, and make it dust free. Prewetting the surface with water before application of Dampblock 2k, and then applying a skim coat of polymerised putty and after drying 2 coats of Smartcare dumpblock 2K @1.5 Kg/ Sqm. (Application of plaster shall be measured and paid in appropriate item).
M/S Parmod Johar (BID ID -3430047)
M/S TRIVENDRA KUMAR (BID ID -3436252)
M/S Sunil Steel Works (BID ID -3436380)
S GOURAV PRAKASH ENTERPRISES (BID ID -3429983)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .