Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.7 LAccepted-AOC 60 MADHUVAN BANK COLONY ALWAR | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹74.7 L+₹4,766.75 (0.06%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in required Class |
Tender Value
₹64.8 L
EMD Value
₹1.2 L
Closing Date
6 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HISAR
HQ CWE HISAR HISAR MIL STN HISAR
PROVN OF ALTERNATE ENTRANCE MAIN GATE WITH ALLIED INFRASTRUCTURE FOR ALWAR MIL STN
2023_MES_581980_1
CWE/HSR/ALW-43 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
ALWAR MILITARY STATION
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE ALWAR
₹1.2 L
17 Apr 2023
20 Feb 2023
8 Apr 2023
20 Feb 2023
6 Apr 2023
23 Mar 2023
Amount
Excavation in trenches not exceeding 1.50m wide and not exc 1.50m in depth and getting out in soft / loose soil .
All as per ser item No 1 here in above but depth exc 1.5 m but n exc 3 m
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing surplus excavated soil to a distance n.exc 50 metre and n exc 100 metre and depositing where directed at a level n.exc 1.5 m above the stafrting point.
PCC (1:4:8) type D-2, using 40 mm graded stone aggregate in fdn mass concrete.
M&L RCC work M-25 Design Mix (using 20mm gradedcrushed stone aggregate )as in foundation including , raft, plinth beam bases for column etc basement slabs under ramed piles and mass concrete
M&L RCC work M-25 Design mix (using 20mm graded crushed stone aggregate) as in columns , pillars , piers posts and struts
M&L RCC work M-25 design Mix (using 20mm graded crushed stone aggregate) as in beams, cantilevers bressumers, lintel over 1.5 mtr span
M&L RCC work M-25 design mix (using 20mm graded crushed stone aggregate) as in slab supported in walls cantilevers etc complete all as specified and directed
M&L RCC work M-25 design mix (using 20mm graded crushed stone aggregate) as in Chajjas
M&L TMT bars, 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per ser item No above but 5mm to 10mm dia as in stirrups, spacers binders etc
M&L form work to side of concrete foundation , footing , bases of columns, raft and raft beams, sides and soffits (If any) of foundation and plinth beams and similar work, vertical or to batter
M&L form work to side of pillar posts struts piers columns etc
M&L form work to sides and soffits of floor or roof beam , beam nauching, griders, bressum-mers lintels cantilevers, shelves including supprots, overhangs etc also splays between floors and beams etc
M&L form work as in suspended slab, such as roof slabs, floor slabs, landings and similar work, not exceeding 20mm thick(Horizonal or sloping)
M&L form work to cullaah hoods, chajjas, throughs and similar items including edges
Treating the bottom and side of exc at the rate 5 ltr/sqm emulsion (ATT) of surface area
Treating the backfil in contact with foundation at the rate of 7.5ltr/sqm (ATT) emulsion of surface area
Treating the bottom surface of floor at the rate 5 ltr/sqm emulsion (ATT) of surface area
Treating the ol under plinth protection at the frate of 5 Ltr/Sqm emulsiom (ATT) of surface area
M&L for 15 mm thick screed bed on fair faces of concrete/brick surfaces in CM 1:4 with water proofing compound @ 3 % of wt of cement finished even and smooth in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane finished complete all as specified (Polymeric membrane and WPC shall be meausred and paid seperately here-in-after)
Supply only integral water proofing compound
M&L water proofing treatement to RCC roof slab including parapet comprising of following course of treatement/specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per sqm over plastered surfaces of roof including parapet surfaces. NOTE : Bituminous primer shall be manufactured by M/S STP Ltd or 'EMW FLATE' M/S Texas India Ltd (b) Over the priming coat laying one layer APP based polymeric membrane of approved manufacturer, 3 mm thick weight not less 3.6 Kgs/Sqm reinforced with non woven polyester fabric weight not less than 150 gms per sqm polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flushing.
M&L two coat of reflective silver Aluminium paint over APP membrane complete all as specified and as directed by the Engineer-in Vcharge
M&L brick work with fly ash 'brick straight or curved on plan exc 6m mean radius built cement mortar 1:6 complete all as specified and as directed
M&L brick work with fly ash 'brick straight or curved on plan exc 6m mean radius built cement mortar 1:4 complete all as specified and as directed
M&L15mm thick rendering in cement mortar 1:4 on fair faces of brick work surace rendering is to be even and smooth with out using extra cenent complete all as specified and directed
M&L15mm thick rendering in cement mortar 1:6 on other than fair faces of brick work surace rendering is to be even and smooth with out using extra cenent complete all as specified and directed
M&L for Rough cast plaster on exterior walls complete all as specified
M&L rendering 5 mm thick in CM 1:3 on concrete ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L rendering 5 mm thick in CM 1:4 on concrete surfaces such as beams, column etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L preparation of newly plasterd surface of wall and applying two coats cement base paint over a coat of primer complete all as specified and dircted
M&L preparation of newly plasterd surface of wall and applying two coats oil bound distemper over a coat of primer complete all as specified and dircted
M&L preparation of newly plastered surface of ceiling applying three coats of white wash
S&F steel window 1.25mm thick box type ERW hollow P section of size 60mm x25mm single rebated comprise of gauged skelton shutter ERW size 50mmx20mm and 1.25 mm thick with two openable leaf consisting two Nos sash bars of T- section 20mmx3mm welded to frame with one vertical mullion of ERW box type T- section of size 60mmx25mm and 1.25 mm thick including cutting holes and making good dismantled portion with PCC (1:2:4) type B-1 (four Nos for each window).
All as per item No 36 above but window with glazed shutter
S&F factory steel ventilator with top hung shutter incl hinges, peg stay complete all as specified and directed
S&F galvanised mild steel wire cloth 0.46 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples to wooden/steel frames with beading complete all as specified & directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane complete all as specified and directed.
S&F frame work such as grills,gratring etc,with ends of bars shouldered &/or riveted or forged into spikes,framed guard bars, barred iron door ladder,frame balusters,walk ways, railing,frame work or water tanks & SImilar work conforming to Fe-290 Gde E-165.
S&F factory made 30mm thick flush shutter, solid core construction, with block board core and plywood face panels, both face covered with deco rative face veneer with lipping/frame to match commercial type on both sides with self closing circular knob for locking arrangemen all as specified and directed.
M&L for factory made 2nd class glazed and skelton door shutter made out of stiles & rails of 30mm thick 2nd class hard wood, klin seasoned and chemically pressure treated & open reabted and prepared to receive glass/gauge etc (without sash bars), edges of framing plain,chamfered of rounded, fitted with and mitred beads for securing glass etc compelte, the SIze of members of shutter shall be as per IS-1003. The shutter shall be fitted to the chowkhats as directed by Engr-in-Charge.
S&F for preparation of new steel surface of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L for preparation of newly wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint (of approved shade) over a coat of pink primer all as specified and directed.
M&L for framed work as in doors or gates angle or other covering door, cooler stand etc to be prepared for handing or sliding with including either hooks and hinges or steel hanging dor fittings (exclusIve of steel or othr covering, running rails and guides) and hanging also fastening and fixing complete conforming to FE-290 Gde E-165.
M&L 75 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete as floor sub base complete all as specified and directed
M&L PCC 25mm thick 1:2:4 type B0 (using 12.5mm graded aggregate) as in floor as in levelling levelling course
M&L machine cut kota stone flooring 18 to 20 mm thick over cement sreed beed 1:4, 20mm thick laid and jointed in grey cement slurry mixed with pigment to match the shed of the slab including rubbing polishing complete all as specified and as directed
All as per ser item No above but as in skirting over and including rendering 10mm thick cement mortar 1:4
M&L for non skid ceramic tiles (coloured) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but n exc 0.18 in floors etc. laid over and including 15 mm screed bed or bedding layer in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile Complete all as specified and directed.
M&L for Glazed coloured ceramic tiles in vertical surface 300x450x7 mm thick over and including 10 mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile Complete all as specified and directed. complete all as specified & directed..
M&L Hardcore of broken boulder gauge n exc 63mm, deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed
M&L 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, Path laid in panel surface finished even and fair without using extra cement including making the joints 10mm thick and filled with mastic bitumen complete all as specified and as directed
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing
S&F exctruted aluminum alloy with galavanisied mild steel hing pin Butt hinges 100mm long
S&F Aluminum anodised, barrel tower bolts of extruded section and fixed 150 mm long
S&F extruded aluminium alloy handles 150mm size fabricated type anodized ISI marked.
S&F mild steel butt hinges medium weight colod rolled of size 100mm, ISI marked complete all as specified and directed.
S&F Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) 300mm long not less than 12mm dia with and incl minimum of 06 bolts and nuts, 4 on plate and 2 on staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, plate and fixed all as specified.
S&F Aluminium anodised tower bolt 300mm long stove enamelled black with bright bolt & fixed.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete
S&F vitreous china squatting pan of Orrisa pattern size 580mmx440mm white with integral foot rest (excluding flushing cistern and flush pipe complete incluidng provision of lime concrete bedding fixed in repair.
Supply and fixing PVC flushing cistern low level 10 ltr cap with inlet ball valve float and handle syphonic action type incl brackets and flush pipe of polythene of low or high density ISI marked.
S&F tubes medium grade 'galvanised' with and including all fitting and fixed bore of 25 mm dia complete to walls and ceiling or laid in floor.
S&F tubes medium grade 'galvanised' with and including all fitting and fixed bore of 15mm dia complete to walls and ceiling or laid in floors of 15mm bore.
S&F 15mm dia stop valve/angle valve of copper alloy fancy type chromium plated screwed down high pressure with crutch or butter fly handle screwed on both ends for iron pipe or for union fixed in repair.
S&F 15 mm bore fancy type long body bib tap, half turn, with wall flange, cast copper alloy with capstan heads, chromium plated, screwed for iron pipe or for brass ferrule, complete all as specified & as directed.
S&F swivel shower rose(fancy type) chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed
S&Fin vitreous china urinal half stall type white excluding flushing cistern , but including PTMT urinal spreader and waste pipe complete all as specified and directed
S&F WHB flat back of SIze 580x450mm excluding taps waste chain plug stopper but incl brackets incl waste pipe cutting pinning in ends of brackets complete.
S&F 15mm dia bore cast copper alloy chromium plated fancy type pillar tap for with out cold & hot water complete all specified and as directed .
S& F 1000 Ltr capacity of rotational moulded polyethylen water storage tank (Cylindrical vertical with closed tap) hoisted and fixed in position including S&F 20mm float valeve 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600 mm long with fitting and including dismantling of tank complete all as specified and as directed by the Engineer-In- Charge.
S& Fixing ball valve brass high pressure with polythene float and fly nut screwed on iron pipe ad fixed 20 mm bore of pipe
S&F PVC connection 15mm size with PTMT nuts of length 600mm.
S&F Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges
S&F PVC (SWR) pipes of 75 mm nominal outside diameter (Type B with wall thickness 3.20 to 3.8 mm) single socketed in any length with rubber ring joints laid in trenches or in floors of 75mm pipe.
S&F PVC (SWR) pipes of 110 mm bore single socketed in any length fixed to wall
S&F PVC (SWR) floor trap, plain with grating including joining with solvent cement 75 mm dia.
S&F PVC (SWR) bend 75mm bore of any radius
S&F PVC (SWR) bend 110 mm bore of any radius
S&F PVC (SWR)110mm Branch piece (single Y ) equal or unequal
S&F PVC(SWR) Vent Cowl
M&L preparation of newly plasterd surface of wall and applying three coats of white wash complete all as specified and dircted
Providing precast cement concrete louvers and jalies 25mm thick (measured solid) including all mouldings but excluding frame(pre cast frame shall be measured separately and paid for under item No 04032
M&L PCC 40mm thick 1:2:4 type B0 (using 12.5mm graded aggregate) as in floor as in floor finishing cement concrete surface without using extra cement complete all as specified and directed
M&L providing precast cement concrete (1:2:4) type B1, using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span,cills, steps, seismic and other similar bands, plinth courses, string courses , lacing courses, parapits and railings upto 60cm in height, copings kneelers, apex stones, bed plates, kerbs not provided for in item No 04028 water throughs and the like including weathering slightly rounded or chamfered angles and throating as directed
S&F 25 to 30mm Dholpur stone cladding gang saw cut with machine cut edges , uniform colour of each stone size exceeding 0.2 and not exceeding 0.5 Sqm area fixed with and including one number SS clamps (grade -202) of flat 30mm x2mm, 150mm long made to shape in each slab making V groove at top and bottom of stone and drilling hole drilling hole for hold fastener, polishing, rubbing & including silicon treatment. The gap between Stone anc wall to be filled with CM 1 6 complete all as specified and directed by the Engineer-in-Charge.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed
S&F Readymade Dholpur stone Chatri (2m height and 1.1m dia) complete all as directed by Engineer in Charge, as approved by GE
M&L Preparation of newly plastered surface of wall, plaster and applying two coat of weather coat exerior emulsion paint (approved shed, over a coat of primer complete all as specified and directed
Surface dressing n.exc. 15 cm deep and getting out as in soft/loose soil.
Surface exc n.exc. 30 cm deep and and averaging 15cm deep and getting out as in soft/loose soil.
Rough excavation not exceeding 1.5mtr deposited an getting out in any type of soil
Rolling and consolidation formation surface by using power road roller with 8 to 12 tone powe roller
Forming Embankment including raising or lowering earth spreading in layers not exc 30cm thick watering and well ramming/rolling and finishing to required size shape etc not exc 1.5 m high from base including compaction of earth filling under optimum mositure content of proctor density 95 percent complete all as specified and directed by Engineer-in-Charge
M&L for 200 mm spread thickness solling (or sub base ) with broken boulders or quarried stone interestices filled surface formed and rolled and consolidated to required camber and gradient complete all as specified
150 mm thick (compacted thickness) (in two layers of 75mm thick sprad thickness and each layr to be rolled and consolidated seperately) with coarse stone aggregate of sand stone, flint or quartizite of grading 2 (63mm to 40 mm size) spread rolled and consolidated to required gradient and camber complete all as specified and directed
Preparing WBM surfaces by brushing with wire brushes for removing cacked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all dirt and loose material applying evenly a tack coat of with bitumen primer 10kg/10 sqm using VG-30 and laying Semi dense asphaltic concrete (Design Mix) 30mm thick consolidted thickness with 5.5% binder content by weight of total mix, using 2% Cement OPC grade by wt of total mix as filler materialrolled and compacted to required camber and gradient with 8 to 12 Ton Power roller complete. Note-mix will be prepared in Hot Mix Plant as per job mix formula obtained from authorised testing lab and laying will be done by mean of mechanical paver.
Preparing existing black top surfaces by brushing with wire brushes for removing cacked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all dirt and loose material applying evenly a tack coat of with bitumen primer 5kg/10 sqm using VG-30 and laying Semi dense asphaltic concrete (Design Mix) 30mm thick consolidted thickness with 5.5% binder content by weight of total mix using 2% Cement OPC grade by wt of total mix as filler material rolled and compacted to required camber and gradient with 8 to 12 Ton Power roller complete. Note-Mix will be prepared in Hot Mix Plant as per job mix formula obtained from authorised testing lab and laying will be done by mean of mechanical paver.
Providing and marking broken centre line/side lines /zebra lines, dashes, arrows, etc on road pavement and the like of any descriptions and width with thermoplastic paint hot applied with machine conforming to BS-3265 and according to the specification laid down by IRC and most (Ministry of suface Transport)specification 2001(4th revision)complete all as specified and as directed
M&L sand filling under floor or in foundations including watering and consolidation
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 grade and fixed with grey cement and pigment over sand cussuion complete all as specified and directed.
M&L providing precast cement concrete (1:2:4) type B1, using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span,cills, steps, seismic and other similar bands, plinth courses, string courses , lacing courses, parapits and railings upto 60cm in height, copings kneelers, apex stones, bed plates, kerbs not provided for in item No 04028 water throughs and the like including weathering slightly rounded or chamfered angles and throating as directed
Taking down old existing curve stone and refixing at other location and makiing good to disturbed portion complete all as specified and directed by the Engineer-in harge.
Stone kerb of roughly squared stones of size 7.5cm x 30cm, all surfaces hammer dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 20mm jointed in cement mortar 1:6 and struck flush
Supply and laying reinforced concrete pipes Class NP-2 pipe, 300mm dia laid and jointed complete with collars
PCC (1:4:8) type C-2, using 40 mm graded stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes tested complete for 300 mm bore concrete pipe.
PCC (1:3:6) type C-1, using 20 mm graded stone aggregate in coping
M&L10mm thick rendering in cement mortar 1:4 on fair faces of brick work surace rendering is to be even and smooth with out using extra cenent complete all as specified and directed
Supply and laying reinforced concrete pipes Class NP-2 pipe, ISI marked, laid to slope in trenches, jointed and tested complete with collars for 150 mm bore pipes.
PCC (1:4:8) type C-2, using 40 mm graded stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes tested complete for 150 mm bore concrete pipe.
Rendering 10 mm thick on fair faces of brick /concrete surfaces in cement mortar (1:4) mixed with water proofing compoud 3% by wt of cement finishing the surfaces even and smooth without using extra cement.(WPC measured seperately)
Cement concrete (1:2:4) type B-1, using 20 mm graded stone aggregate in surface channels of drains and benching including finishing the top of benching even and smooth using extra cement Notes :- Forming fair finished channel shall be measured and paid for separately.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ectra cement including forms, moulds mitred/stopped ends etc.
Precast reinforced cement concrete M-20 (Nominal mix using cement content 360 kg/cubic metre) using 20mm graded stone aggregate for manhole cover including placing in position and set in CM (1:4)
Construction of septic tank for 10 user designed to carry sewage and sludge water all as specified and shown on drawing No CEJZ/2002/TD/S2 sheet No 1/1
Soakage well, excavation in any type of soil , foundation in PCC 1:3:6 walls of hony combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover , inter connecting pipes in RCC/DWCcomplete filled with brick bats of size 1.2mtr dia and 3mtr effective depth
S&F wall mounted indoor voltage stabilizer automatic operation single phase and designed for input variation between 90 V to 300 Volts with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 1 KVA. Model No. VEW 150 Plus of Make V-Guard or eqvivalent in Microtek, Luminous complete all as specified & directed.
Supply and installation of desert cooler of MS sheet minimum thickness 20 sheet gauge electric driven (230 volts, single phase, 50 Hz supply) having nominal air flow capacity of 5000 cum per hour or nearest higher standard size) including following accessories :-(a) Pump Make:-Khaitan/Crompton Greaves/Cool Home (b) Fan motor copper wound single phase, 240 volts, Ac three spread Make:-Khaitan/Crompton Greaves/Cool Home (c) Switches/Regulator Make:Anchor/Havells/Legrand complete all as specified.
Supply and installed water cooler,electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 litre per hour cpomplete all as specified and directed.Make:Bluestar/Voltas
Supply and fix Water heater storage type ,electric driven ,cap. 25 ltr ,BEE ,5 star rated all as specified and directed.
Supply , fixing, laying GI pipe medium grade galvanized ISI marked Including fittings for dia 50 mm of pipes
Supply , fixing, laying GI pipe medium grade galvanized ISI marked Including fittings for dia 20 mm of pipes
Supply and installled gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe and fixed on wall ,complete for size 50 mm dia
Supply and installled gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe and fixed on wall ,complete for size 20 mm dia
M&L for bends(any type, radius and angle)tapers any type(straight,bend,increasing,decreasing or double socket etc.) Tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot or all ends flanged) collars,caps and plugs
M&L for cutting the existing CI/GI/DI pipeline of size upto 150 mm dia in position for insertion of ` T` joints or making branch connection as required or directed by Engineer-in-Charge.
Construction of brick masonary valve pit /chamber complete with MS cover and locking arrangement suitable for the following size:- (a)1050 X 750 X 1000mm type 'C'
M & L Sand cushioning to PVC underground cable with screened and washed sand and punning to provide a required cover.
M&L bricks for protection cover to underground cable (with old size sub class `B` bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm as directed by Engineer in-charge.
M&L for steel tubular swaged poles type 410 SP-31 of 9 mtr long with CI base plate and finial taper plug, bolts, nuts & screws including foundation and coping complete all as specified by Engr-in-Charge.
Supply, Installation, commissioning and testing of High Intensity type LED based street light of 70/75 W,IP 65 rating new generation energy saving and environmental friendly long life versatile pressure dia-cast aluminium IP roadway luminair with high power LED as light source complete with all fittings and pre wired as directed and specified.
Supply and fix SMC street light control box of size 300 x 200 x105 mm including aluminium bus bar of adequate capacity and one no. MCB SP 16 Amps 230 volts including connecting up with the electrical connections and fixing and clamping complete and all as directed.
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.
Supply, install, testing and commissioning (including CPRI type test certified) factory made LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-65 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber. The panel shall be dust and vermin proof, made of 3.15 mm CRCA MS sheet and with base frame of 40x40x6mm angle iron , powder coated, having front and rear openiable hinged double door shuters with aprons for cable entry and locking arrangement complete :- (Main Panel) Incoming (a) MCCB 200 amps, 4 pole, 18 KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01 Nos. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp, 4 pole not less than 60 cm long mounted on insulators. (c) Digital Load manager multi functional energy meter having facility to measure true RMS value, KWH, neutral current, for quadrant energy, max demand (KW, KVA, Kvar & Amp), CT operated 415 volts, 50 Hz AC supply including CTs. -01 set. (d) LED indicating lamps (R, Y & B) -01 Set. Outgoing (a) MCCB 100 amps, 4 pole, 30 KA (Icu = 100% Ics), with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 03 Nos. (b) MCCB 63 amps, 4 pole, 30 KA , with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01 No.
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of size following sizes :-(a) 95 Sqmm 3.5 core
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of size following sizes :- (b) 10 Sqmm 2 core
M&L for boring of holes under road,pavement,hard,standing by trenchless technology using ultra sounding techanique and necessary machine including HDPE pipe of 150 mm dia for 0.4 mpa working pressure
M&L for galvanised steel tubing light grade of size 40 mm bore for protection of under ground cable on poles / walls under road crossing etc complete all as specified & directed.
Material and labour for point wiring with 1.5 sqmm single core multistranded copper conductor fire resistant low smoke (FRLS) PVC insulated and unsheathed cable 1100 Volts grade confirming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20 mm external dia) but shall be increased as per actual site requirement in accordance with clause No 19 125 of SSR Part-I ISI marked with wall thickness not less than 1.8 mmincluding conduit accessories like bends, tees, jnction boxes etc fixed concealed/recessed in wall or ceiling including 1.5 mm FRLS PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitble size with bakellite white/coloured top sheet cover 3.0 mm thick for one light point controlled by one way switch all as specified & directed.
All as per serial item no 143 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item no 143 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item no 143 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item no143 here-in-before but for one 3 pin 15/16 Amp socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 volt grade includig 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continous earth wire in green colour.
Supply and fixing switch piano ,flush type, single pole, one way 5/6 Amp 230 Volts.
Supply and fixing switch piano ,flush type, single pole, one way 15 Amp 230 Volts.
Supply and fixing socket outlet 3 pin (with 2 pin outlet also) 5/6 Amp flush type 240 Volts.
Supply and fixing socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type 240 Volts.
Supply and fixing ceiling rose surface bakelite 65 mm*50mm with two or three terminal complete all as specified.
Supply abdfixing decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly energy efficient suitable for 16 W to 20W with LED tube or modelE-LITE LED pride and connecting up complete all as specified and directed. Make Havells cat part no LHEXBLP7PN1W018 or equivalent of Surya/philips/Crompton Greaves bajaj/Wipro/GE.
Supply and fixing sheet metal enclosures double type suitable for fixing MCB's. SPN with 200 Amps rated bus bar 8 way 240 Volts.
S&F MCB 32 Amp single pole & neutral 240 volts C curve 10 KA ISI Marked as per IS/IEC 60898-1 2002 Make legrand/Havells /ABB.
S&F MCB 6-32 Amp single pole & neutral 240 volts C curve 10 KA ISI Marked as per IS/IEC 60898-1 2002 Make legrand/Havells /ABB.
Supply and fixing 2nd class hard wood rectangular block open recessed of size 30cm*225mm*5cm depth with 3mm thick phenolic laminated sheet top cover fixed screws &PVC rawl plug (4 Nos) for DB complete all specified & directed.
M/s S Amarjit Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .