| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC AOC | |
| 2 | L2₹29.7 L+₹35,672.45 (1.21%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹29.9 L+₹52,431.45 (1.79%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹30.8 L+₹1.5 L (4.97%)Rejected-AOC D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹31.7 L+₹2.3 L (7.84%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹77,600
Closing Date
11 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon
CA NO. GE(P)AF/GUR-82/2022-23 IMPROVEMENT TO BLDG NO P-1, T-15, T-33 and T-34 AT AF STATION PALAM UNDER GE (AF) GURGAON NO.1 .
2023_MES_579134_1
GE (P) AF/Gur-82/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹77,600
21 Mar 2023
4 Feb 2023
13 Mar 2023
4 Feb 2023
11 Mar 2023
25 Feb 2023
Amount
Taking down plain or corrugated AC sheet of any description including removing from site complete all as specified and directed.
M&L for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screw including rubber washer complete all as specified and directed by Engr-in-Charge.
M&L for pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridge and Valley/Gutter fixed with self tapping screw including rubber washer complete all as specified and directed .
M&L Roof trusses (framed), purlins,crane, gantries,rails and fastening and heavy bracket framing (beams,tee ,angle, chnnel or flat sections) including distance pieces etc confirming to Fe 410-W(GdeE-250) quality 'A' complete all as specified and directed .
Dismantling of floor, hearth, or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles from site and rubbish off the premises complete all as specified and directed .
S & F vitrified tiles light shade 10mm thick (square/rectangular) polished, area of each tile n.exc. 0.36 sqm, in floor etc.,set and jointed in neat cement slurry over 15mm thick screed bed in CM 1:4 and pointed in white or coloured cement with pigment to match for laying floor fineshes complete all as specified and directed .
Demolition of Cement Concrete (un-reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing the same from Site(s), complete all as specified and as directed.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `B' for 100mm thick concrete slab complete all as specified and directed .
M&L for 150mm thick PCC 1:2:4 Type B2 (using 40mm graded stone aggregate) as in Floor/hard standing in line and level and laid in alternate panel including tamping and top surface make rough, whilst the concrete is green complete all as specified and as directed .
M&L for 20mm thick wear proof topping by using approved metalic floor hardner as specified, laid on concrete floors and pavings in panels after applying neat cement slurry @ 3.00Kg/Sqm and top surface finished even and smooth complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness laid dry or laid dry and pointed in floors, aprons etc and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M&L 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed .
M&L for machine pressed precast concrete interlocking paver block glossy finish, any shape & size with grey cement & pigment conforming to IS 15658-2006 of 60 mm thickness M-35 grade over 25mm thick sand cushioning, complete all as specified and as directed . ( note : sand cushioning shall measured and paid separately under respective item of schedule)
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed .
M&L in repair for Chequered Cement Concrete Tiles 300X300X 25mm thick pre printed colour, Set and Jointed in Neat Cement Slurry with Grey Cement and Pigment over and including screed bed 20mm thick in cement mortar 1:6 as in path etc, complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 Type C2 (using 40mm graded stone aggregate)as in plinth protection and courtyard, finished even and smooth/fair with out using extra cement complete all as specified and directed.
M&L for precast cement concrete Kerb stone even and smooth face of PCC Type B1 (using 20mm graded stone aggregate) including chamferring etc and finishing exposed surface in CM 1:4 with even and smooth finish, including fixing in position and removing old kerb stone complete all as specified and as directed.
M&L for applying two coat weather/dust proof paint in Strips exc 15 Cm, over a coat of primer including preparation of new/old Surface of Kerb Stone& plastered wall surfaces all as specified and as directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping, benching, bed block, window cills etc complete all as specified and as directed by Engr-in-charge
Taking down door/window frame with shutter of area exc 1.50 but n exc 4.0 Sqm each and removing from site complete all as specified and as directed.
Taking down door/window frame with shutter of area n exc 1.50 sqm each and removing from site complete all as specified and as directed.
S&F MS framed work as in doors or gates of angle or other section as chowkhat., tie bar, hold fast, guard bars complete cooler stand etc, drilled for fixing complete Fe-410 complete all as specified and as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or welded complete all as specified and as directed.
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
M & L Preparing newly untreated steel surfaces of any descripton over 10 cm wiidth or girth and applying two coat of synthetic enamel paints over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel & steel based surface of any description not otherwise described over 10 cm width & girth and applying one coat of synthetic enamel paint by Auto Roller complete including Scaffolding up to 4 storey buildings all as specified and as directed .
S&F aluminum alloy sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheets, cast of exctruded sections and fixing bolts or extruded section and all as specified.
S&F extruded anodised aluminum alloy handle 150mm long fabricated type complete all as specified and as directed.
S&F anodised aluminum barrel tower bolt of extruded section 150mm long complete all as specified and as directed.
S&F 100 mm butt hinges made up of extruded anodised aluminum, complete all as specified and as directed.
S & F in repair floor door stopper of size 75/140 mm long aluminium alloy body and tongue, anodized with hard drawn steel spring incl cleats etc fixed to door complete all as specified and as directed.
M&L preparation of new surfaces of wood of any description not otherwise described width or girth and applying two coats of synthetic enamel paint over & incl one coat of pink primer complete all as specified.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M & L for brick work with sub class 'B' Bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 as in manholes/drain complete all as specified and as directed.
Dismantling of wall and ceiling boards (Fibre, pulp, insulation, wooden etc.) or insulation board / slabs any thickness incl cover fillets complete all as specified and as directed.
M&L for GI frame work for seamless ceiling comprising of GI perimeter chennel 0.55mm thick with two unequal flanges of 20 and 30 mm web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intrmediate channel 0.90 mm thick having two equal flanges of 15mm each and web of 45mm seuspended from sofits at approx 900 mm centre to centre with and including ceiling section (not exc 1.2m length) of 0.55 thickness having kurld web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate chennel with connecting clip across the intermediate chennel at 457 mm centre to centre, completed all as specified and directed.
M&L for providing and fixing Glass Reinforced Gypsum Board (GRG) 12mm thick in ceiling fixed with screw complete all as per manufacturer's instructions and as directed..
Excavating in Trenches, not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, for Foundation, Manhole, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50m and deposited where directed at level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundation , filling and mass concrete complete all as specified and as directed.
Taking down Cement Plaster/Grit plaster from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. (Note :- Rate included for four storey building including skefolding and all safety measures)
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately)
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces including finishing even and smooth without extra cement all as specified and as directed by Engineer in Charge.
M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surface as in ceiling finished even and smooth w/o using extra complete all as specified and directed by Engr-in-charge
M&L for 15mm thick rendering on brick or concrete surfaces in internal surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered walls surface and applying two coat of exterior emulsion paint 100% acrylic of approved colour over a coat of primer including 1 to 2 mm thick birla putty punning and necessary scaffolding upto 4th floor complete all as specified and directed by Engineer-in-charge.
M&L for preparation of plastered or un plastered new decorated surfaces of ceiling by Vacuum based sanding machine all as specified, filling cracks/hole by applying wall care putty and applying one coat oil emulsion distemper white or coloured by auto roller complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of newely plastered Wall surface and applying three coats of white wash complete and all as specified and as directed
M&L for preparation of newly plastered surfaces of walls by Vacuum based sanding machine complete all as specified, applying wall care putty upto 1mm thick as required (multi purpose mixer shall be used for uniform and proper mixing of putty) and applying two coats oil emulsion distemper white or coloured over a coat of approved primer by auto roller complete all as specified & directed by Engineer-in-Charge.
Removal of debris/malwa/ excavated surplus earth to a distance exc 10 Km but n exc 15.00 Km out side MD land complete all as specified and directed.
E/M Portion
Labour only for taking out unserviceable DBs by carefully disconnecting the existing connections, complete all as specified and directed
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multistranded copper conductor in and including cutting of chases to lay PVC rigid concealed conduit (medium grade), exposed to surface wherever required including conduit as specified and making good to surface by using CM 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also complete including PVC insulated and unsheathed FRLSH single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one, one way switch including taking down of old u/s wiring complete all as specified and as directed.
One light/fan point controlled by one switch
One 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm
One 3 pin socket outlet, 5amps, independent board with other switches.
All as per item No 55 here in before but using 4 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant low smoke ( FRLS ) cable for 1 5 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc including taking down of old u/s wiring required complete all as specified and directed.
S&F modular switch 1 Way 6 Amp , complete all as specified and as directed.
S&F Modular socket 6A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F Modular socket 2 in 1, , 3 pin, 6/16Amp complete all as specified and as directed.
S&F modular switch 1 Way 16Amp , complete all as specified and as directed.
Supply & Fixing of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engineer - In-Charge.
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 20mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 2.5 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ AC plug points complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F GI Modular gang sunk-in pressed terminal boxes of required size not less than 1.2 mm thick factory made for following module complete all specified and directed. Note: Flushing of module box in wall with cement and repairing the wall as before is deemed to be included in quoted rate.
Metal flush box 2 module
Metal flush box 3 module
Metal flush box 6 module
M&L modular white cover plate with frame 2 module complete all specified and directed.
M&L modular white cover plate with frame 3 module complete all specified and directed.
M&L modular white cover plate with frame 6 module complete all specified and directed.
Supply and fix in replacement of factory made epoxy polyster powder coated distribution board Triple pole and neutral double door 4 way 415V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for as one incommer TPN and 12 outgoings single pole MCB complete all as specified and confirming to IS: 8623 Make: Legrand /Siemens/Schneider. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
S&F in repalcement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN of 4 poles and current carrying capacity 63 Amp in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 3.5 core complete all as specified and as directed.
Ditto as above item no 71 but LT XLPE cable 16 sqmm 4 core.
M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed. Note :- Compacted / punned thickness of sand cushioning shall be measured for the payment.
M&L for brick protection with sub class 'B' Designation 75 old bricks laid dry flat 23cm in width over sand cushioning in trenches as perpendicular to the direction of underground cable complete all as specified and as directed.
S&F in repair GI pipe light grade 50mm bore in trenches/wall/poles for protection of cable complete all as specified and as directed.
M&L for carrying out horizontal boring below roads/PCC hard standing/Drain suitable Up to 50 mm dia GI pipe as per site requirement for inserting GI pipe of 50 mm size with a depth upto 1.5m & length of road upto 12m complete all as specified and as directed.
Note:- The amount of Rs 72,160/- against Schedule of Credit on Page No 138 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
M/S RK Builders
DR Buildcon
M/s Navansh Engineers & Consultants
Parveen Builders
M/S Parshant Associates
P R Constructions
GIR RAJ BUILDERS
JAIPAL AND BROTHERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .