Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.0 LAccepted-AOC 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹8.5 L+₹52,622 (6.60%)Rejected-Finance | 2 | Rejected-Finance Not Lowest | |
| 3 | Rejected-Technical CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | - | Rejected-Technical Not enlisted in tender cat | |
| 4 | Rejected-Technical | - | Rejected-Technical slow progress of related firm |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
2 Jun 2021, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152116
Repair and Maint to summer appliances such as Air Conditioners, Water Coolers, Desert Coolers, Refrigerators, AC Plant and Voltage Stabilizers etc at Military Station Abohar
2021_MES_440645_1
GE ABH-11/21-22
Open Tender
Civil Works
Item Rate
120 days
Abohar Mil Stn
MES Registered Contractor enlisted in class E Category c (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
Garrison Engineer Abohar
₹20,000
Yes
17 Jun 2021
5 May 2021
4 Jun 2021
5 May 2021
2 Jun 2021
20 May 2021
Amount
Taking down old and unserviceable sealed compressor and Supply & fixing of new sealed compressor hermetically of capacity 150/150 Ltrs,Suitable for water cooler , including cleaning ,Vaccumizing, Gas charging of adequate qty with Testing on load complete all as specified and directed by Engr-in-Charge.make : Kirloskar/Tecumsah/LG/Godrej.
All as per description of Srl item No1ere-in-before but sealed unit compressor suitable for water cooler capacity 60/120 Ltrs, all as directed by Engr-in-Charge.
All as per descrirtion of Srl item No 1 here-in-before but sealed unit compressor suitable for water cooler capacity 40/80 Ltrs, all as directed by Engr-in-Charge.
Supply & fixing in replacement Water taps brrass chromium plated heavy duty Internal thread / outer thread for 15mm bore pipe, all as specified and directed by Engr-in-Charge. Make : Jindal/Johnson.
Supply & fixing in replacement of Fan motor for Water cooler of capacity 1/4 HP, 1400 RPM, 230 volts AC for water cooler of capacity 150/150 Ltrs, 60/120 Ltrs & 40/40 Ltrs. Make : Danfoss/Ranutrol/Anapurna complete all as specified and directed by engr-in-charge.
Material & labour for charging of refrigerant gas in Water cooler of capacity 150/150 ltrs/60/120 ltrs & 40/80 ltrs including pressure/leak testing etc complete all as specified and directed by Engr-in-charge.
Taking down old and unserviceable sealed compressor and Supply and fixing new hermetically sealed compressor suitable for 1.5 ton window type AC complete including accessories and cleaning , vaccumizing ,gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge pipes complete all as specified and directed by Engr-in-Charge Make :Gujral /Carriar/Voltas/ Sidhwal/ Tecumsah.
All as per description of srl item No7 here-in-before but suitable for split type AC of 2.0 Ton.
All as per description of srl item No 7 here-in-before but suitable for split type AC of 1.5 Ton.
Servicing and maintenance of AC's Split type/Window Type of any make with acid for cleaning of condenser & evaporator coil, complete all as directed by Engr-in-Charge.
Supply and Fixing in replacement of Double shaft blower motor for ACs window 240 volts single phase AC supply,all as directed by Engr-in-charge. Make : As per site requirement
Supply and fixing in replacement of PVC Blower fan suitable for window type AC 1.5 Ton capacity size power & make all as directed by Engineer-in-Charge.
Material & labour for charging of refrigerant gas in Window type / Split type Ac 1.5/2.0 Ton cap including pressure/leak testing etc complete all as specified and directed by Engr-in-charge.
Supply & fixing indoor unit of Split Type AC of capacity 1.5 Ton Including cooling coils and connecting items,complete all as specified and directed by Engr-in charge. Make : Voltas/Blue Star/Gujral/LG.
All as per item No 14 here-in-before but out door unit of capacity 1.5 TR including connected Items such as condenssor coil, compressor,Fan motor , fan blade,and all electric works complete all as specified and directed by Engr-in-charge.Make : Voltas/Blue Star/Gujral/LG.
Supply & fixing for PCB remote plate of AC split type 1.5 Ton/2 Ton complete with remote, all as directed by Engr-in-Charge. Make : As per site requirement.
Supply and fixing new hermetically sealed compressor suitable for Refrigerator of capacity 286/310 Ltrs complete including accessories and cleaning , vaccumizing ,gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge pipes complete all as specified and directed by Engr-in-Charge. Make:-Kirloskar/Teccum Sah/Sriram/Godrej/ Samsung/whirlpool /LG
All as per item No 17 above but for Refg of capacity 165/175 .
Material & labour for charging of refrigerant gas in Refrigerator of any size including pressure/leak testing etc complete all as specified and directed by Engr-in-charge.
S & F cooling coil of Refrigerator Capacity 180 /280 /310 Ltrs including connected works complete all as specified and directed by Engr-in-charge.
Supply and fixing new hermetically sealed compressor suitable for 'D' Freezer of capacity 500 Ltrs complete including accessories and cleaning , vaccumizing ,gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge pipes complete all as specified and directed by Engr-in-Charge. Make:-Kirloskar/Teccum Sah/Sriram.
All as per item No 21 above but for D Freezer of capacity 200/300 ltrs complete all as specified and directed by Engr-in-charge.
Material & labour for charging of refrigerant gas in D freezer of any size including pressure/leak testing etc complete all as specified and directed by Engr-in-charge.
Supply & Fixing in Replacement of Fan motor of capacity 1/8 HP,1400 RPM, three speed suitable for desert cooler .
Supply & Fixing in Replacement of Submersible water pump (Tullu pump) single phase ,220 V for desert cooler complete all as specified and directed by Engr-in-charge.
Supply & fixing Wood wool pad for desert cooler of any size complete set of three superior quality as approved by Engr-in-Charge.
Material & labour for Repair of Automatic Voltage stablizers of capacity 2 KVA/ 3 KVA / 5 KVA single phase with replacement of following spares parts/accessories and including provision of minor spares like connecting wire, plug top, switch, cocket etc, and including taking down old spares and duly tested on load all as specified and directed after taking repair and servicing. Note : Spares like Auto cut relays, voltmeter, Ammeter, dry transformer and PCB measured and paid separately under relevant items of the schedule.
S&F Auto Cut relay for 2 KVA to 5 KVA stablizer
S&F Volt meter 0-300 volt range single phase 230 volt suitable for 2 KVA to 5 KVA stabilizer
S&F Ammeter not less than 0-20 Amps range single phase 230 Volt suitable for 2 KVA to 5 KVA stabilizer
S&F dry transformer single phase 230 Volt suitable for 2 KVA to 5 KVA stabilizer
S&F PCB (Panel circuit board) single phase 230 Volt suitable for 2 KVA to 5 KVA stabilizer
Supply and fixing Starting Capacitor mfd 80-100 Mfd for water cooler and D freezer. Make Bhel/Keltron/Tibcon.
Supply and fixing Running capacitor 10 to 20 Mfd for water cooler and 'D' Freezer.
Supply and fixing Running Capacitor 36 MFD for AC complete all as specified and directed by Engr-in-charge.
Supply and fixing Over load protector suitable for any size of Acs. Complete all as specified and directed by Engr-in-charge
Supply and fixing over load protector suitable for Water cooler of different size . Complete all as specified and directed by Engr-in-charge.
Supply and fixing over load protector suitable for Deep freezer , Complete all as specified and directed by Engr-in-charge.
Supply and fixing over load protector suitable for Refrigerator of any size . Complete all as specified and directed by Engr-in-charge.
Supply and fixing Thermostats switch (thin below) Suitable for water cooler complete all as specified and directed by Engr-in-charge.
Supply and fixing Thermostats switch (thin below) Suitable for Acs complete all as specified and directed by Engr-in-charge.
Supply and fixing Thermostats switch (thin below) Suitable for D freezer complete all as specified and directed by Engr-in-charge.
Supply and fixing Thermostats switch (thin below) Suitable for Refrigerator complete all as specified and directed by Engr-in-charge.
Supply and fixing Starting relay for any sealed comprressor of 1/6 or 1/8 capacity compressor Suitable for Acs complete all as specified and directed by Engr-in-charge.
Supply and fixing Starting relay for any sealed comprressor suitable for Water coolers
Supply and fixing Starting relay Suitable for Refrigerator complete all as specified and directed by Engr-in-charge
Supply and fixing Starting relay Suitable for Deep Freezer complete all as specified and directed by Engr-in-charge
Supply and fixing Biometal fuse suitable for Refrigerator complete all as specified and directed by Engr-in-Charge.
Supply and fixing Timer suitable for Refrigerator complete all as specified and directed by Engr-in-Charge.
Supply and fixing PVC pipe ( 15 mm ) for desert cooler complete all as specified and directed by Engr-in-charge.
Supply and fixing Starting capacitor 4 mfd heavy duty.Make : Usha/Tibeon/Keltron
Supply and fixing Metal Clad Industrial Plug ( Male) 2 Pole + Earth,250 Volts for Acs & Geyser,
Supply and fixing Metal Clad Industrial Socket ( Female) 2 Pole + Earth,250 Volts for Acs & Geyser,
Supply and fixing water distributero of PVC type junction suitable for desert cooler for desert cooler of size 1/2" Make ISI Mark
Supply and fixing elbow (PVC) for desert cooler of size 1/2" Make ISI Mark
Supply and fixing PVC connection of 15mm bore & 600mm length for connecting main pipe line suitable for Desert cooler with PTMT Make ISI mark.
Supply and fixing 3 Pin Triangular Plug Top 6 Amp ,240 Volts.
Supply and fixing 3 Pin Triangular Plug Top15/16 Amp ,240 Volts.
Supply and fixing sheet Metal enclosure with socket plug top and MCBs 20 Amp single pole (AC box) Make : Indoasian/Havells
Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan,cutting the unserviceable winding of starter, rotor and taking out ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as specified and directed and re-assembling complete ceiling fan fixing only with old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- 1. Ball bearing, Gun metal bush and condensor are measured and paid separately as supply only rates and minor spares like rubber bush shackle,holder deemed to beinclude in quoted rates). 2. Repair/Rewinding of fan shall be carried out in MES yard to bring adequate winding machine,tools & plants and necessary motor winder at site as directed.
All as per Item No.56 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep.
All as per Item No.56 here-in-before but pedestal/Air circulator/Wall mounted fan of size 400/450 mm sweep.
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, servicing/overhauling and replacement of bush, bearing, condenser complete all as specified and directed and writing MES number as as directed by Engr-in-Charge. (Note :1. Bush, condensor, ball bearing are measured and paid separately as supply only rates and minor spares like , rubber bush shackle,holder deemed to be include in quoted rates ) 2. Repair/Servicing of fan shall be carried out in MES yard/User site to bring adequate serviceable condition winding machine,tools & plants and necessary motor winder at site as directed.
All as per item No 59 here in before but exhuast fan 220/250/300/380/450 mm sweep complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge
Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, including filling the cavities with filler material and painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint after reassembling spares for serviceable condition complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge. Note: 1. painting of fan shall be carried out in MES yard/User site to bring adequate winding machine,tools & plants and necessary motor winder at site as directed.
All as per Item No.61 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep.
All as per Item No.61 here-in-before but pedestal/Air circulator fan of size 400/450 mm sweep.
Supply only ball bearing number of 6201/6202/6203/6204 as required complete all as specified and directed. (Make : SKF/NBC).
Supply only gun metal bush as per existing specification and make as per sample and confirming to ISI complete all as specified and directed.
S&F for Condenser 2/2.5/3.15.4.0 MFD as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed. (Make : Universal/Standard/Jyoti/Usha)
S&F for PVC holder for condenser housing as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed.
S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
S&F for twin core twisted copper flexible wire/cable of size 23/0.0076 complete all as specified and directed (Make : Finolex/Nicco/KDK/KEI/Havells/HPL)
Supply only canopy top/bottom suitable for 20 mm dia ceiling fan rod suitable matching color as exising complete all as specified and directed
Supply only down rod 300 mm long of size 20 mm dia for ceiling fan complete all as specified and directed.
Supply only ceiling fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed.
Supply only Exhasust fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed.
Supply only exhaust fan canopy suitable size as per exising size of fans 220/250/300/380/450 mm suitable to matching color complete all as specified and directed
Supply only exhaust fan Louvers GI/MS/PVC suitable to size as per exising fans 220/250/300/380/450 mm complete all as specified and directed
Supply only fan regulator electronic (socket) type, single phase, 230Volt complete all as specified and directed Make: Anchor/Cona and equivalent make
Material and labour for making hole of size 220/250/300/380/450 mm round/Square as required for exhaust fan vent to using suitable tools without disturbing other surface and make good with cement plaster and exising color white wash/distemper/putty as existing color and surface including grouting bolts, nuts into wall for fixing exhaust fan complete all as specified and directed.
N.R.Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .