Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹41.5 L+₹1.7 L (4.17%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹42.1 L+₹2.2 L (5.61%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹43.8 L+₹4.0 L (9.96%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Jan 2023, 6:00 pmClosed
GE Minniebay
Junglighat PO Port Blair
REPAIR/MAINT OF STREET LIGHTS, BOLLARD LIGHTS, BAY LIGHTS, POST LAMP FITTING, POLES CABLE SYSTEM AND CONNECTED ITEMS AT NTS, NAD, DAD, MARCOS, PROTHRAPUR, CHOULDARI AND INS UTKROSH UNDER AGE E/M II AT GE MINNIEBAY, PORT BLAIR
2022_MES_570624_1
8206/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹80,000
Yes
9 Feb 2023
23 Dec 2022
21 Jan 2023
23 Dec 2022
18 Jan 2023
5 Jan 2023
Amount
Excavation in soft / loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable complete all as specified and as directed by Engr-in-Charge
Excavation in soft / loose soil not exceeding 1.5 mtr wide and exc 1.5 mtr depth and not exc 3.0 Mtr and getting out incl forming of bottom for laying cable complete all as specified and as directed by Engr-in-Charge
Excavation in hard / dense soil including road cutting etc not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable complete all as specified and as directed by Engr-in-Charge
Returning filling using excavated soil including spreading levelling, watering and well ramming in layers n exc 25 cms complete all as specified and as directed by Engr-in-Charge
Removal of surplus excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement on load change over switch 415 V, 4 pole, 100 A complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement on load change over switch 415 V, 4 pole, 125 A complete all as specified and as directed by Engr-in-Charge
Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 63A complete all as specified and as directed by Engr-in-Charge
Supply & fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 63A complete all as specified and as directed by Engr-in-Charge
Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100A complete all as specified and as directed by Engr-in-Charge
Supply & fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 100A complete all as specified and as directed by Engr-in-Charge
Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 125A complete all as specified and as directed by Engr-in-Charge
Supply & fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 125A complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 36 KA, 250A complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 36 KA, 250A complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement MCB SP 5 to 32 Amps, 440V, 10KA 'C' Curve complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement MCB SP 40 to 63 Amps, 440V, 10KA 'C' Curve complete all as specified and as directed by Engr-in-Charge
S&F in replacement straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed and making the disturbed surface after relaying the cable and making joints suitalbe for aluminium conductor of 16 to 25 Sqmm 3.5 core complete all as specified and directed. Note : (ii) Taking up cable, excavation, returning filling and removal of surplus soil upto 1 cum meter shall be included in the qouted rate. (ii) More than 1 cum shall be measured and paid separately under relevant items of this schedule.
All as per item 18.00 above but 35 to 70 Sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge
All as per item 18.00 above but 95 to 150 Sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge
Supplying and laying in replacement of GI tubing light grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of 80 mm dia all as specified and directed:- Note : Necessary excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant items of this schedule, if cable is laid in trenches
All as per item No 21.00 above but 50 mm dia complete all as specified and as directed by Engr-in-Charge
All as per item No 21.00 above but 40 mm dia complete all as specified and as directed by Engr-in-Charge
Supply and laying in replacement of LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor of 10 Sqmm 2 core complete all as specified and as directed by Engr-in-Charge Note : Necessary excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant items of this schedule, if cable is laid in trenches
All as per item No 24.00 above but 10 Sqmm 4 core complete all as specified and as directed by Engr-in-Charge
All as per item No 24.00 above but 16 Sqmm 4 core complete all as specified and as directed by Engr-in-Charge
All as per item No 24.00 above but 25 Sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge
All as per item No 24.00 above but 35 Sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge
All as per item No 24.00 above but 50 Sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge
All as per item No 24.00 above but 95 Sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge
Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed
All as per item No 31.00 above but outer dia of 63mm and inner dia 50mm complete all as specified and as directed by Engr-in-Charge
All as per item No 31.00 above but outer dia of 77mm and inner dia 63mm complete all as specified and as directed by Engr-in-Charge
All as per item No 31.00 above but outer dia of 120mm and inner dia 103mm complete all as specified and as directed by Engr-in-Charge
M&L for fixing in replacement earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point. (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
Supply & Fix in replacement aluminium cables lugs for cables of size upto 10 Sqmm including necessary crimping with crimping tool complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement aluminium cables lugs for cables of size upto 16 Sqmm including necessary crimping with crimping tool complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement aluminium cables lugs for cables of size upto 25 Sqmm including necessary crimping with crimping tool complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement aluminium cables lugs for cables of size upto 35 Sqmm including necessary crimping with crimping tool complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement aluminium cables lugs for cables of size upto 50 Sqmm including necessary crimping with crimping tool complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement aluminium cables lugs for cables of size upto 70 Sqmm including necessary crimping with crimping tool complete all as specified and as directed by Engr-in-Charge
M & L for repair of LT Panel board outdoor type repair/replace damaged door hinges set of three nos front and back side and legs 40x40x6mm MS angle and necessary cutting, welding & drilling hole etc.works required at site ccomplete all as specified and as directed by Engr-in-Charge
M&L for providing cement concrete Type D2 1:4:8 using 40mm graded stone aggregate in foundation filling and mass concrete for foundation for pole etc all as specified and directed.
M&L for providing cement concrete Type C1 1:3:6 using 20mm graded stone aggregate in foundation filling and mass concrete for coping of pole etc all as specified and directed.
M&L for providing cement concrete Type B1 1:2:4 using 20mm graded stone aggregate in foundation filling and mass concrete for coping of pole etc all as specified and directed.
Supply, Install, test and commissioning in replacement of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) S & F copper bus bar 300 Amp with collared heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conical type at a maximum interval of 500 mm- 01 Set. (b) S&F MCCB FP 125 Amps 25 KA - 01 No for main in coming
Supply, Install, test and commissioning in replacement of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following:- (a) S & F copper bus bar 400 Amp with collared heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conical type at a maximum interval of 500 mm- 01 Set. (b) S&F MCCB FP 100 Amps 35 KA - 01 No For Main incoming
S&F in replacement pole cap made out of MS including one coats of aluminium paint over two coat of red oxide primer over pole cap suitable for 8.5 / 9.0/ 11.0 mtr long tubular pole including threaded hole 3 Nose and suitable size of nut and bolts complete all as specified and directed.
M & L for painting steel tubular poles 9/11 Mtr long including cross arms etc. with one coat of aluminium paint including preparation of surfaces and writing feeder name and pole number on the pole complete all as specified and directed by Engr-in-Charge
M & L for painting RCC poles 9/11 Mtr long including cross arms etc. with one coat of cement base paint including preparation of surfaces and writing feeder name and pole number on the pole complete all as specified and directed by Engr-in-Charge
M & L for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coats of grey or colour as approved by GE / Engr in -Charge as per site suitability synthetic enamel paint including door welding with hinges complete as specified and directed
S &F in replacement LED 26 Watt solar street light fittings having 4500 lumen out put, 12V 60 Watt PV module, Lithium ferro phosphate (LiFePO4) battery of rating not less than 380Wh, integrated MPPT charger with driver, IP-65 Protection, PIR technology based motion sensor. LED indigator for battery charging and discharging, Tilt angle adjustable type mouting bracket suitable for octagonal pole complete all as specified and directed
Supply & Fix in replacement LED driver 12 to 20 Watt for street light/flood light/high bay light all as specified and directed.
Supply & Fix in replacement LED driver 25 to 40 Watt for street light/flood light/high bay light all as specified and directed.
Supply & Fix in replacement LED driver 45 to 75 Watt for street light/flood light/high bay light all as specified and directed.
Supply & Fix in replacement LED driver 100 to 150 Watt for street light/flood light/high bay light all as specified and directed.
Supply & Fix in replacement Surge protection device (SPDs) for street light/flood light fixing in before place driver in street light surger protection rating up to 2 KV all as specified and directed.
S&F in replacement GI bracket for fixing street/ security light fitting made out of GI pipe medium grade 40 mm dia 1.50 Mtr long bent to required angle/ shape complete with MS flat iron clamp of size 50x5 mm, nut, bolt, washer of suitable size as per site requirement etc and fixed in pole/wall including two coats of aiuminium paint over a coat of red oxide primer to MS clamps , nut ,bolts etc complete all as specified and directed
S&F in replacement GI bracket for fixing street/ security light fitting made out of GI pipe medium grade 25 mm dia 1.50 Mtr long bent to required angle/ shape complete with MS flat iron clamp of size 25x5 mm, nut, bolt, washer of suitable size as per site requirement etc and fixed in pole/wall including two coats of aluminium paint over a coat of red oxide primer to MS clamps , nut ,bolts etc complete all as specified and directed
S&F in repalcement steel tubular swaged poles complete with cast iron base plate, finial taper plug,bolts,nuts & screws as specified type SP-31 (9.0 Mtrs long) with single curve at the top for fixing of street light fitting all as specified and directed
S&F in replacement of FRP boxes with 4 connectors heavy duty, and clamps made out of FI 32 x 6mm and GI nuts, bolts , busbar chamber size 30x20 cm including provn of Aluminium Busbar SPN 30 Amps capacity fixed on porcelain insulator, 01 No MCB SP 6 Amps Capacity complete all as specified and directed
S & F in replacement analog time switch with battery back up of 100 hours, having current capacity 16 A, 3P module 240 volts with 1 changeover for controlling of security light fitting with proper connection and testing all as specified and directed.
M&L for fixing in replacement submain wiring for two single core PVC insulated unsheathed , 1100 Volts grade, copper cable 1.5 Sqmm multistranded conductor and drawing through and including rigid PVC conduit of suitable size but not less than 20mm dia with conduit accessories etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 1.5 Sqmm copper conductor fixed to poles with saddles and screws and all as specified and as directed Note :- One run of PVC conduit, two runs of cable1.5 Sqmm and one run of earth wire 1.5 Sqmm shall be measured and paid as one unit.
S&F in replacement of Street light fitting LED type, 25 Watts 240 Volts lumen efficiency not less than 100 lm/Watt and accessories complete, mounted on 25 mm dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall,connection complete all as specified and directed
S&F in replacement of Street light fitting LED type, 72 Watts 240 Volts high luminous , energy efficiency not less than 100 lm/Watt , including SPD fitting before placing the street light and accessories complete mounted on light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall,connection complete all as specified and directed
S&F in replacement of Street light fitting LED type, 90 Watts 240 Volts high luminous , energy efficiency not less than 100 lm / Watt , including SPD fitting before placing the street light and accessories complete mounted on light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall,connection complete all as specified and directed
S&F in replacement of smart bright Flood light fitting LED type, 120 Watts 240 Volts lumen efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light opties , efficient housing output LED sleek and robust design for better aesthetics , highly efficient reliable and sturdy, mounted on wall,connection complete all as specified and directed by Egineer-in-Charge
S&F in replacement of smart bright Flood light fitting LED type, 150 Watts 240 Volts lumen efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light opties , efficient housing output LED sleek and robust design for better aesthetics , highly efficient reliable and sturdy, mounted on wall,connection complete all as specified and directed by Egineer-in-Charge
S&F in replacement energy efficient post top light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integrated LEDs assuring soothing warm white light all night long LED 40 W black case aluminuim, including all necessary wiring , clamps, nut and bolts mounting accessories etc all as specified and directed
S&F in replacement energy efficient bollard light 360 degree light distribution with IP-65 fitting on ground, wall etc including excavation and PCC 300cmx300cm as required and high quality integrated LEDs assuring soothing warm white light all night long LED 10 W black case aluminuim including all necessary wiring , clamps, nut and bolts mounting accessories etc all as specified and directed
S&F in replacement of high bay light 150 W 220V 50 Hz innovatirely designed hear sink for superior thermal management high efficiency round highbay in PDC housing, luminaire upto 130Lm/W ,IP-66 complete all as specified and directed
bansal construction
M/s Pooja Enterprises
NAVJEEVAN ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .