| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-Finance | L1 | Accepted-Finance AS PER BOQ | |
| 2 | L2₹3.3 L+₹10,350 (3.23%)Accepted-Finance | L2 | Accepted-Finance AS PER BOQ | |
| 3 | L3₹3.4 L+₹24,570 (7.67%)Accepted-Finance | L3 | Accepted-Finance AS PER BOQ | |
| 4 | Rejected-Technical | - | Rejected-Technical EPF, ESI Not Submited |
Tender Value
₹3.3 L
EMD Value
₹3,250
Closing Date
10 Jan 2024, 1:00 pmClosed
Superintending Engineer
Electricity Distribution Circle II Saharanpur
Various Work of deposit scheme shift 11 KV line Railway Fatak at in area EDSD ITI.
2023_PVVNL_870980_2
179/W/EDC II/SRE/2023-24
Open Tender
Electrical Works
Lump-sum
45 days
SAHARANPUR
please refer tender document
2 documents required · 2 mandatory
₹1,180
SE EDC II SRE
₹3,250
Yes
12 Jan 2024
3 Jan 2024
10 Jan 2024
3 Jan 2024
10 Jan 2024
3 Jan 2024
Amount
Detail of Work
Safely carriage of ST pole (11 Mtr. Long) from ESC, SRE/JE store to site of work at various sites including loading & unloading at both ends.
Safely carriage of other complete line material (Except ST Pole) from ESC, SRE/JE store to site of work at various sites including loading, unloading at both ends
Erection of double on ST Pole (11 Mtr. Long) with complete fitting with all accessories as per RESPO specification.
Fixing of 11 KV stay rod by digging of pits in block of 600x600x300 mm. & with new brick and nozzling of stay wire 7/10 SWG and fitting the same on the pole
Concreting of stay rod in ration 1:4:8 with Ist class brick ballst with cement sand
Providing and Fixing of Stone Ped 300x300x75 as per RESPO specifications
Earthing of pole Complete by earthing Rod .
Fixing of 11 KV TPMO set on double Pole.
Fixing of 11 KV Fust set on double Pole.
Providing of various size clamp for ST poles with nuts bolts made of new MS falt iron 50x6 mm.
Providing of MS nuts & bolts and washer off size.
Removal of old weasel conductor from the existing 11 KV line with making roll of conductor shifting the site to ESC, SRE/JE store including loading and unloading at both ends.
Laying, lifting, Stringing, sagging jumpering & binding of ACSR Rabbit conductor for 11 KV Line including complete.
Concreting of ST Pole with cement concreting in block of 600x600x1500 mm in ration 1:4:8 with cement sand and Brick ballast size 1x1.5 sq mm. Plinth
Safe Removel of 250 & 400 KVA T/F from the existing plinth after opening HT & LT connection by private crane
Constriction of plinth for installation of 250 & 400 KVA T/F of size 1.5x1.5x1 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC Top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall as per RESPO Specification.
Safely installation of 250 & 400 KVA T/F on the Plinth with Complete fitting including making connection and commissioning
Neutral & body Earthing of 250 & 400 KVA T/F by boring of 60 ft. deep & fixing of 60 ft.G.I. Pipe 11/2” Dia ( Jindal class B ) and connecting with G.I. Strip of size 40X5 mm and G.I. wire.at bottom of G.I. pipe to the T/F providing of required charcoal & salt in the pipe.
Providing of various size Alu. Lug Bolted Type.
Laying and making connections of LT XLPE cable 1x240 & 1x400 sq.mm. from T/F to double pole (approx to 40 Mtr.)
Providing & fixing of Wiremesh fencing size 2.5x2.5x2.5 mtr with grouting making frame of MS angle 40x40x6 mm and fixing four no ms strip size 25x6 mm at equal distance in between the frame and fixing square mesh of 50 mm squre in each frame the fencing should cover all side of T/F with providing 1 no door size 6x3 with sitakni & Dandala
GYAS PAL CONTRACTOR
SHREE RAM ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .