Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹16.6 L+₹1.6 L (10.6%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹17.5 L+₹2.4 L (15.9%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹18.2 L+₹3.1 L (20.7%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹23.4 L+₹8.4 L (55.7%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
27 Apr 2023, 6:00 pmClosed
GE (SB) KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, FITTING AND FIXTURES, SPLIT / WINDOW ACs, WATER COOLERS, REFRIGERATION UNITS INCLUDING EARTHING IN INHS PATANJALI AND MES OFFICE COMPLEX UNDER GE(SB) KARWAR.
2023_MES_577142_2
8984/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE(SB) KARWAR
AS PER TENDER
7 documents required · 7 mandatory
₹500
Yes
GE (SB) KARWAR
₹52,000
Yes
1 May 2023
11 Apr 2023
29 Apr 2023
11 Apr 2023
27 Apr 2023
13 Apr 2023
11 Apr 2023 - 12 Apr 2023
Amount
Rectifying the defects in domestic fluroscent tube/CFL light fittings/wall security light fitting any type and at any height,ceiling rose, electric bell by tightening loose connections and rectifying defects, testing complete all as specified and directed.
Opening switch mounting plate at normal height upto 1.5 m , rectifying the defects in fittings and fixtures such as switches, bell push, fan regulator, sockets etc by tightening loose connections, refixing switch plate and testing complete all as directed. NOTE for Item No 1.00 & 2.00: The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as "S & F in repairs" under relevant items of this schedule hereinafter and in such cases the above items will not be measured and paid for.
Taking down carefully copper point wiring (light, fan, socket and power) complete(fittings to be measured separately) and making good surfaces of walls/floors etc complete all as specified and directed.
M & L for surface point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & capping medium grade with all accessories on wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed cable 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:
a) One light / fan point controlled by one switch
b) One 3 pin socket outlet 5 Amp on same board with other switches.
c) One 5 pin socket outlet 5 Amp on independent board.
d) One 3 pin 5 Amps socket outlet independent but below the switch board of light points in the same vertical plate.
All as per item No 4.00 above but with cables 2.5 Sqmm for one light/fan point on independent board and size of earthing cable 2.50 Sqmm complete all as specified.
All as per item No 4.00 above but with cables 2.5 Sqmm for one 3 pin socket outlet 5 Amps on independent board
All as per item No 4.00 above but with cables 4 Sqmm for one 3 pin socket outlet 15 Amps on independent board and size of earthing cable 4 Sqmm
M & L for concealed point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS sheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in PVC conduit, sunk pressed steel or cast iron terminal boxes and 3 mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed cable 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all making good disturbed surfaces with CM(1:4) to match with the existing surface complete as specified and directed for the following:
(a) One light/fan point controlled by one switch .
(b) One 3 pin socket outlet 5 Amp on same board with other switches.
(c) One 3 pin socket outlet 5 Amp on independent board.
All as per item No 8.00 above but with cables 4.00 Sqmm for one 3 pin socket outlet 15 Amps on independent board and size of earthing cable 4 Sqmm.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Supply & fix in repairs MCB TPN, 16 to 32 Amps, ''C'' series 415 Volts, 3 phase, 10 KA capacity all as specified and directed.
Supply & fix in repairs MCB Single Pole Neutral, 32 Amps, ''C'' series 230 Volts, Single phase, 10 KA capacity all as specified and directed.
Supply & fix in repairs MCB SP, 6 to 32 Amps, 'C' series 230 Volts, Single phase, 10 KA capacity all as specified and directed.
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding, etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. NOTE: (a) The unit rate quoted shall be deemed to include for minor items viz nuts, bolts split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and paid separately under relevant items of this schedule. (c) Rewinding of fan will be measured and paid for separately under relevant item of this schedule.
Supply and fix in repairs capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed.
Supply and fix in repairs bearing No. 6201/6202/6203 suitable for ceiling fan/exhaust fan complete all as directed.
M & L for removing of burnt out winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enamelled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
Description all as per item No 17 above but exhaust fan of 300 mm sweep.
Description all as per item No.17 above but exhaust fan of 380 to 450 mm sweep.
M & L for sub main wiring with 2 runs of single core PVC insulated FRLS suitable for 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking cable of size 6 sqmm and one run of 1100 V grade PVC insulated FRLS unsheathed 4.0 sqmm multistranded copper conductor cable 1100 Volts as in continuous earth drawn through PVC casing capping complete for sub main wiring in walls/roof all as specified and directed. NOTE: Two runs of cable 6.0 Sqmm and one run of 4.0 Sqmm cable shall be measured as one running meter unit.
Supply & Fix exhaust fan of 300 mm sweep after assembling at site including electric connection from ceiling rose to connector with flexible cord twin core twisted copper of size 23/0.0076 and testing including taking down old defective exhaust fan and depositing the same to MES store yard complete all as specified and directed.
Supply & fix exhaust fan of size 380 mm sweep, metal body including electric connection from ceiling rose to connector with flexible cord twin core twisted copper of size 23/0.0076 and testing including taking down old defective exhaust fan and depositing the same to MES store yard complete all as specified and directed.
Supply & fix exhaust fan of size 450 mm sweep, metal body including electric connection from ceiling rose to connector with flexible cord twin core twisted copper of size 23/0.0076 and testing including taking down old defective exhaust fan and depositing the same to MES store yard complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including electric connection from ceiling rose to connector with flexible cord twin core twisted copper of size 23/0.0076 and testing including taking down old defective ceiling fan and depositing the same to MES store yard complete all as specified and directed. MAKE: Crompton Greaves or equivlent make in Baja/Khaitan as approved by GE.
Taking down submain wiring cable any number of runs alongwith earth wire from the existing with or without concealed or surface conduit complete all as specified and directed.
M & L for sub main wiring with 2 runs of single core PVC insulated FRLS suitable for 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking cable of size 4 sqmm and one run of 1100 V grade PVC insulated FRLS unsheathed 2.5 sqmm multistranded copper conductor cable 1100 Volts as in continuous earth drawn through PVC casing capping complete for sub main wiring in walls/roof all as specified and directed. NOTE: Two runs of cable 4 Sqmm and one run of 2.5 Sqmm cable shall be measured as one running meter unit.
M & L for sub main wiring with 2 runs of single core PVC insulated FRLS suitable for 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking cable of size 4.00 sqmm and one run of 1100 V grade PVC insulated FRLS unsheathed 2.5 sqmm multistranded copper conductor cable 1100 Volts as in continuous earth drawn in and including surface PVC conduit medium grade 20 mm bore and accessories of suitable size complete for sub main wiring in walls/roof and making good disturbed surfaces with CM(1:4) to match with the existing surface all as specified and directed. NOTE: Two runs of cable 4.00 Sqmm, one run of 1.5 Sqmm cable and one run of PVC conduit pipe shall be measured as one running meter unit.
M & L for sub main wiring with 2 runs of single core PVC insulated FRLS suitable for 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking cable of size 6.00 sqmm and one run of 1100 V grade PVC insulated FRLS unsheathed 4.0 sqmm multistranded copper conductor cable 1100 Volts as in continuous earth drawn in and including surface PVC conduit medium grade 20 mm bore and accessories of suitable size complete for sub main wiring in walls/roof and making good disturbed surfaces with CM(1:4) to match with the existing surface all as specified and directed. NOTE: Two runs of cable 6.00 Sqmm, one run of 4.0 Sqmm cable and one run of PVC conduit pipe shall be measured as one running meter unit.
S & F in repairs MCB Distribution board, Single pole neutral 240 Volt, 12 way, double door powder coated steel sheet enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as directed.
S & F in repairs MCB Distribution board, Triple pole neutral 415 Volt, 4 way, horizontal double door powder coated steel sheet enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as directed.
Supply and fix in repairs switch piano 5 Amps one way flush type, matching with existing make, ISI marked, all as specified and directed.
Supply and fix in repairs decorative modular switch 6 Amps single pole flush type complete all as specified and directed.
Supply and fix in repairs five stepped type electronic fan regulator fluch type on the existing phenolic laminated sheet etc, 230 Volts single phase complete all as specified and directed.
Supply and fix in repairs switch socket combination 2 in 1, 5 Amps flush type, matching with existing make ISI marked, all as specified and directed.
Supply and fix in repairs switch socket combination 5 Amps/16 Amp, 5 in 1 flush type, multi purpose, matching with existing make ISI marked, all as specified and directed.
Supply & fix in repair ceiling rose surface bakelite 65 x 50 mm three terminal, all as specified and directed.
Supply and fix in repair lamp holder, insulated body with back plate suitable for angle / batten fitting all as specified and directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complet.
Supply and fix in repairs for driver for LED panel 36W 2'x2' LED luminare, 240 Volt all as directed. Make : Shakti , Cat no :SZARHIX036 or equivalent in Bajaj/Havells
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface mounting type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complet. Make : Shakti , Cat no :SZSBLMX036 or equivalent in Bajaj/Havells
Supply and fix in repairs for LED panel 18 W 1ft x 1ft Recess LED luminare , 240 Volt suitable for tubelight fitting all as directed. Make : Shakti , Cat no :SZRELMX018 or equivalent in Bajaj/Havells
Supply and fix in repairs for LED panel 18 W 1ft x 1ft surface mounted LED luminare , 240 Volt suitable for tubelight fitting all as directed. Make : Shakti , Cat no :SZSELMX018 or equivalent in Bajaj/Havells
Fixing only in repairs LED tube rod 36/40/20 Watt including taking down existing light all as directed. NOTE: Tube rod 20 / 36 / 40 W will be issued under Sch 'B' free for fixing only.
Supply and fix in repairs Integral sleek extruded polycarbonate batten for LED tube light with white acrylic cover suitable for 1x20 watts LED tube light. Make : Shakti Cat no :SZSRFX1x20 or equivalent in Bajaj/CG/Havells. NOTE: LED tube rod will be measured and paid seperately.
Supply and fix in repairs LED tube rod 18/20 Watt, 6500 K, 1200 mm long complete all as specified and directed. Make : Shakti Cat no :SZFRTMX020 or equivalent in Bajaj/CG/Havells.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fix in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 Amp single pole MCB 240 Volts all as specified and directed.
S&F in repairs MCB DB SPN, 8 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. Make : Havells/Legrand/L&T or equivalent.
Supply & fix in repairs MCB TPN, 40 to 100 Amps, ''C'' series 415 Volts, 3 phase, 10 KA capacity all as specified and directed.
S&F in repairs bell electric (ding dong bell) 230 volts AC, single phase complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S & F in repairs LED Wall Light Prismatic LED decorative wall light suitable for LED Bulbs B22 or E27, with Bulb ,Engineering polymer housing for durability and optimum light output. Make : Shakti , Cat. Ref.: SZWWGXX009 or equvalent in Bajaj / Havells
M & L for rectification of defects and making functional Deep Freezer, split / floor mounted AC, water cooler & refrigerator of any capacity of existing makes incl rectification of minor defects such as tripping of MCBs, wherever necessary, rectifying loose electrical connections, making fresh connections in electric panel / connector etc, making functional defective drain pipe blockage/leakage etc, checking of functionality of compressor of any capacity etc complete all as specified and directed.
M & L for periodical maintainance of split type AC of 1.5 / 2 Ton capacity including cleaning of overhead ceiling supported indoor unit complete, blower, outdoor unit, wiring system, cool air vent, cleaing including oiling / greasing of movable parts of indoor unit such as motor bearing etc, fresh electrical connections, checking insulation of wiring etc complete, all as specified and directed.
All as per item No 52.00 above but for 3 ton capacity (2 x 1.5 Ton Outdoor unit one No and indoor unit 2 Nos)
Supply & Fix in repairs copper condenser coil of size 20 x 30" x 1 rows suitable for 1.5 TR outdoor unit of split AC.
Supply & Fix in repairs copper condenser coil of size / 22 x 32" x 1 rows suitable for 1.5 / 2.00 TR outdoor unit of split AC.
Material & Labour only for gas charging with required quantity of R-22 & R-134A refrigerant gas in refrigeration circuit of AC of capacity 1.5/2.00 Ton capacity complete all as specified and directed by Engr-in-charge.
Material & Labour only for leak testing of refrigerant gas including all allied works such as vaccumising the complete system, soap leak test, nitrogen gas pressure test, replacement of flux, flare nut, dead plug, dead cap, brazing etc including necessary welding work, testing and commissioning upto satisfactory performance of the refrigeration system.
S & F in repairs reciprocating / rotary compressor hermetically sealed type single phase 230 V, 1.5 Ton capacity suitable for split type AC, factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.
S & F in repairs reciprocating / rotary compressor hermetically sealed type single phase 230 V, 2 Ton capacity suitable for split type AC, factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.
S & F in repairs compressor hermetically sealed type single phase, 230 V suitable for water cooler of 80 litre storage capacity and 40 litre per hour cooling capacity, factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.
Supply & fix in repair fan motor single phase 240 Volts metallic body for out door unit of split AC suitable for 1.5/2 Ton of existing RPM & setting with remote unit all as specified and directed.
Supply & fix in repair fan motor single phase 240 Volts metallic body for indoor unit of split AC suitable for 1.5/2 Ton of existing RPM & setting with remote unit all as specified and directed.
S & F in repair fan blade assembly of alumunium frame for outdoor unit suitable for split AC of any capacity of existing make all as specified and directed.
M & L for taking down unserviceable fan blower motor of any HP capacity from outdoor unit of split type AC 1.5/2 TR capacity and rewinding motor with super enamelled copper wire , insulataing materials , varnishing, drying etc, replacement of bush, assembly etc suitable for exisitng make and fixing it back complete all as specified and directed.
S & F in repairs PVC air filter for split type AC 1.5/2 Ton capacity complete all as specified and as directed.
S & F in repairs pendent control assembly with cord and PC circuit suitable for existing split type AC of 1.5 Ton capacity complete all as specified & directed.
S & F in repair LMS & overload relay assembly for 1.5/2 Ton compressor of Split type AC complete all as specified & directed.
S & F in repair of copper tube size 5/8" indoor suitable for split / floor mounted ACs including brazing complete all as specified & directed.
S & F in repair of copper tube size 3/8" indoor suitable for split / floor mounted ACs including brazing complete all as specified & directed.
S&F in repair copper tube insulation with heatlon or Superlon insulation material.
Supply and fix in repairs capacitor 1.5 to 6 mfd, 230 Volt single phase complete all as specified & directed.
Supply and fix in repairs capacitor 36-45 mfd, 230 Volt single phase complete all as specified & directed.
Supply and fix in repairs contactor single phase model 3 TH 30 ,22 E suitable for out door unit 2 x 1.5 Ton capacity of existing make all as specified & directed.
Taking out carefully split type air conditioner of capacity 1.5/2 Ton with frame as required and refixing the same at another site/new location including making the good distrubed surfaces as per existing specifications to entire satisfaction of Engineer-in-Charge.
Supply and fixing/laying in repairs 20 mm bore PVC pipe to walls for drain out condensing water of split AC including cutting of floor/opening for making holes in walls and making good the same after fixing/laying pipe complete all as specified and directed
Supply & Fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and deisigned for input variation between 170 volts to 250 volts with out put voltage at stablized at 230 volts with accuracy of +/- 2.50% and of capacity 4 KVA.
SRI GURUPRASAD INFRATECH
ANKIT SHIP REPAIRERS AND SUPPLIERS
SHRI MALLIKARJUN BATTERY AND ELECTRICAL WORKS
M/s. Prakash Engineers Contractors and Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .