Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 2 | L2₹8.6 L+₹26,778.70 (3.21%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹8.8 L+₹45,295 (5.43%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
8 Jul 2024, 6:00 pmClosed
GE Air Force Bihta
Air Force Station Bihta - 801103
REPAIR/MAINT, FILLING OF DITCHES ON SHOULDERS, LEVELLING AND REPAIR/MAINT AND CLEANING OF MONSOON DRAINS AND REPAIR/MAINT RUNWAY SIDE DRAINS, APPROACH ROAD, HARD STANDING AND OTHER MISC WORKS AT AF STN BIHTA
2024_MES_658905_1
8413/BHT/E8
Open Tender
Civil Works
Item Rate
150 days
Bihta
Class E and above and category a(i)
6 documents required · 6 mandatory
₹500
Yes
GE (AF) Bihta
₹20,000
Yes
23 Sept 2024
10 Jun 2024
15 Jul 2024
10 Jun 2024
8 Jul 2024
26 Jun 2024
11 Jun 2024 - 17 Jun 2024
Amount
Surface dressing n.exc. 15 cm deep in soft/loose soil and clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance, complete all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, in all kinds of soils as directed by Engineer- in- charge, complete all as specified and directed.
Demolition of concrete of any description and in any position including removal of demolished materials n.exc 50 Mtr. etc. complete all as specified and directed.
Demolition of brick work or stone boulders masonary built in cement mortar including all arches, pillars etc., complete all as specified and directed.
M&L for cement concerte 1:3:6 type C2 (using 40mm graded stone aggregate) in Cement concrete in surface channels and drains, complete all as specified and directed.
M&L for brick work with old size fly ash bricks class 10, straight or curved on plan exc. 6.0 m mean radius built in CM 1:6, complete all as specifed and directed.
M&L Providing cement concrete 1:3:6 Type C1 using 20 mm graded stone aggregate as in coping, complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work, cement concrete surface in CM 1:4, surfaces finished fair & even without using extra cement, complete all as specified and directed.
Cleaning of monsoon drains by desilting, desludging and removing grass, foreign and any type of deposited materials from bottom surface and sides of top portion of drain wall and removing rubbish from site to a distance exc. 100 m and n.exc. 200 m, complete all as specified and as directed. Note:- Plaster work in patch work where damaged by grass/ vegetation required shall be measured saperately under respective item.
Hiring of 01 No. of JCB (Hydraulic excavator cum front end loader) including POL and 01 No. driver for excavating (inside MOD Land), loading, spreading of soil, complete all as specified and directed.
Hiring tractor with trolly including POL and 01 No. driver for transporing & unloading of earth material, complete all as specified and directed.
Rolling and consolidating formation surfaces by power mechanical roller exc. 8 tonne & n.exc. 12 tonn in cutting/filling include for watering as necessary and consolidating to the required level, gradient or camber, keeping roller wheels wet, if required, filling in hollows and depressions, complete all as specified and directed.
Demolition of Concrete (un-reinforced) in ground floors and pavings exc. 15 cm thickness above ground level and removing demolished material to a distance not exc. 100 m, complete all as specified and as directed.
M&L rendering 15 mm thick on fair faces of brick work or cement concrete surfaces in CM 1:4, surfaces finished even & smooth using extra cement, complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8, type D-2 as in sub base for flooring, complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:2:4, type B-2 as in flooring, hard standing, path etc., complete all as specified and directed.
M&L finishing surface of concrete roads, pavements, hardstanding by brooming, complete all as specified and as directed.
M&L for Forming Construction joint 30 mm deep x 10 mm wide filled with sealing compound grade B, complete all as specified and directed.
S&F 20 mm thick Expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘B’ for 100 mm thick concrete slab, complete all as specified and directed.
RADHESHYAM PASWAN
Bikarma Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .