Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.7 LAccepted-AOC 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹59.3 L+₹5.5 L (10.3%)Rejected-Finance | L2 | Rejected-Finance Not lowest tender | |
| 3 | L3₹67.3 L+₹13.5 L (25.1%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance Not lowest tender | |
| 4 | L4₹71.3 L+₹17.5 L (32.5%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Not lowest tender | |
| 5 | Rejected-Technical B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | - | Rejected-Technical Not qualifying experience criteria and financail soundness criteria for class C contractor along tender fee and EMD yet not been received. |
Tender Value
₹70.0 L
EMD Value
₹1.3 L
Closing Date
20 Nov 2021, 6:00 pmClosed
CWE AF PALAM
COMMANDER CWE (AF) PALAM
SPECIAL REPAIR/REPLACEMENT OF BER COOLING APPLIANCES AT CAMERO COMPLEX UNDER GE (AF) SUBROTO PARK
2021_MES_473105_2
CA NO CWE/PM/SP-13/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF SUBROTO PARK
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE AF SUBROTO PARK
₹1.3 L
Yes
10 Dec 2021
23 Oct 2021
22 Nov 2021
23 Oct 2021
20 Nov 2021
6 Nov 2021
Amount
Supply and install hi wall split units indoor/outdoor copper tube evaporator and copper condensor, R32 Gas and condencing unit capacity of 2 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 4.5 CFC free, inverter type AC of capacity 2 Ton fitted on wall and outdoor to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc up to 3 mtr all as specified and directed by Engineer -in -Charge.
Supply and install hi wall split units indoor/outdoor copper tube evaporator and copper condensor, R32 gas and condencing unit capacity of 1.5 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 4.5 CFC free,inverter type AC of capacity 1.5 Ton fitted on wall and outdoor to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts, clamping of 3 core copper cable, cooling tube, drain water pipe etc up to 3 mtr all as specified and directed by Engineer -in -Charge
Supply and install of room window type air conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour (1.5 Ton). BEE 5 star rated inverter type AC with copper condensor evaporated fixing in window/existing bracket including providing necessary locking arrangements and brackets i,e wooden piece, angle iron support, screwing, necessary nut bolts, drain pipe and electrical connections all as specified and directed by Engr-in-Charge.
Supply and install refrigerator suitable for operation on 230 volts 50 Hz AC supply of capacity 195 ltrs (or nearest higher size) single door type having minimum 5 star rating suitable for CFC free refrigerant smartinverter compressor complete, all as specified and directed by Engineer-in-Charge.
Supply and install refrigerator double door, shiny steel suitable for operation on 230 volts 50 Hz AC supply of capacity 310 ltr (or nearest higher size) double door type having minimum 3 star rating suitable for CFC free refrigerant smart inverter compressor complete, all as specified and directed by Engineer-in-Charge.
Supply and install refrigerator suitable for operation on 230 volts 50 Hz AC supply of capacity 285 ltr (or nearest higher size) double door type having minimum 3 star rating suitable for CFC free refrigerant complete, all as specified and directed by Engineer-in-Charge.
Supply and install water cooler fully stainless steel electric driven single phase having storage and nominal cooling capacity 40 ltrs (or nearest higher size) suitable for CFC free refrigerant single phase 230 V 50 HZ complete with provn of drain water pipe of suitable dia and accessories complete all as specified and as directed by Engineer-in-charge.
Supply and install water cooler fully stainless steel electric driven single phase having storage and nominal cooling capacity 150 ltrs (or nearest higher size) suitable for CFC free refrigerant single phase 230 V 50 HZ complete with provn of drain water pipe of suitable dia and accessories complete all as specified and as directed by Engineer-in-charge.
Supply and install Deep Freezer hard top up to 320 litre capacity having single door electric driven single phase having approximate storage capcity of 320 ltrs (or nearest higher size) suitable for CFC free refrigerant single phase 230 V, 50 Hz complete with provision of drain water pipe of suitable dia and accessories complete all as specfied and directed by Engr-in-Charge.
Supply and fix desert cooler electric driven (single Phase ) having nominal air flow capcity of 4000 CuM per hour (or nearest size) and above 40 Ltr water capacity steel body with angle iron support fixing with electrical connections as approved by GE all as specified and directed by Engr-in-Charge.
Supply and fix desert cooler electric driven (single Phase ) having nominal air flow capcity of 5000 CuM per hour (or nearest size) and above 40 Ltr water capacity steel body with angle iron support fixing with electrical connections as approved by GE all as specified and directed by Engr-in-Charge.
Supply and install Cassette type AC units indoor/outdoor copper evaporator & copper condensor complete with cordless remote control unit, twin rotary compressor, three phase, 380 V- 415 V, 50 Hz, CFC free inverter type of capcity of 4 TR complete all as specifed and directed by Engr-in-Charge.
S&F Low density polyethylene pipes (LDPE) 20 mm dia of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors etc. including accessories, clamps and fastners complete all as specified and as directed by Engineer-in-charge
M&L laying of copper tubing of dia 1/2" including insulation and brazing work complete, all as specified and as directed by Engineer-in-charge.
M&L laying of copper tubing of dia 1/4" including insulation and brazing work complete, all as specified and as directed by Engineer-in-charge.
Supply and laying in replacement of refrigerant line copper tubing of size 5/8" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and as directed by Engineer-in-charge
Supply and laying in replacement of refrigerant line copper tubing of size 3/8" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of foam insulation for copper tubing of size 5/8" complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of foam insulation for copper tubing of size 3/8" complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of foam insulation for copper tubing of size 1/2" complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of foam insulation for copper tubing of size 1/4" complete all as specified and as directed by Engineer-in-charge
S&F in replacement of unserviceable PVC insulated and PVC round sheathed with stranded coper conductor (flexible) industrial cable 1100 volts conforming to IS-694 of size 4.0 sqmm 3 core complete all as specified and directed.
S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable 1100 volts conforming to IS-694 of size 2.5 Sqmm 3 core complete, all as specified and directed by Engineer-in-Charge.
S&F sheet metal three pole and neutral encls with three pin end earth plug and socket capacity 20-32 Amps complete with one TP MCB capacity 20-32 Amps complete, all as specified and directed by Engineer-in-charge
S&F in replacemnt of GI tubing medium grade 20 mm with all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / sadding on walls / ceiling etc complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of gun metal gate valve with iron wheel head screwed both ends for iron pipe 20mm dia complete all as specified and as directed by Engineer-in-Charge.
Disconnecting from mains dismantling taking down and depositing of old unserviceable Spilt type AC 1.5 TR-35 Nos, Split Type AC 2.0 TR-18 Nos, Window AC 1.5 TR-26 Nos, Water cooler-20 Nos, Cassette AC-04 Nos, including connected accessories like refrigerant tubing stand electric cable etc and deposit to MES store yard complete, all as specified and directed by Engineer-in-Charge.
M&L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of condensing unit on the wall / ground complete all as specified and as directed by Engineer-in-charge
Satish Kumar Gupta
BRIJ MOHAN LAL AND CO.
RUCHIKA ENGG.WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .