Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND OVERALL REASONABLE | |
| 2 | L2₹21.3 L+₹3.4 L (18.8%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹22.3 L+₹4.4 L (24.6%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹22.4 L+₹4.5 L (24.9%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹24.3 L+₹6.5 L (36.0%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 Jan 2023, 6:00 pmClosed
GE (NW) KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR /REPLACEMENT OF METER PANELS, MS SHEET METAL ENCLOSURE, SUBMAIN WIRING, DBS, CONTROLS SWITCH, LED LIGHT FITTINGS AND OTHER MISC WORKS AT MD ACCN / OTM ACCN AT NAVAL STATION KARANJA
2022_MES_570207_1
8625/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) KARANJA
REPAIR /REPLACEMENT OF METER PANELS, MS SHEET METAL ENCLOSURE, SUBMAIN WIRING, DBS, CONTROLS SWITCH, LED LIGHT FITTINGS AND OTHER MISC WORKS AT MD ACCN / OTM ACCN AT NAVAL STATION KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE (NW) KARANJA
₹80,000
Yes
2 Mar 2023
20 Dec 2022
18 Jan 2023
20 Dec 2022
16 Jan 2023
3 Jan 2023
20 Dec 2022 - 3 Jan 2023
Amount
Taking down carefully copper/aluminium point wiring( light, fan socket or powder)through steel / pvc conduit / casing caping (fitting such as switches, ceiling roses , pendants regulators socket etc to be measured separately) making good disturbed surfaces of floor etc. complete all as specified and directed.
M & L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including PVC CASING CAPPING(ISI marked) with all accessories including surface / concealed sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor ( using green colour) to common earth and connecting to earth dolly, complete all as specified & directed for One light /fan/bell point controlled by one switch 5 Amp, SP, one way complete all as specified and directed.
All as per BOQ item No 2 above but One 5 Amp, 3 Pin socket point on the same board complete all as specified and directed.
All as per BOQ item No 2 above but One 5 Amp, 3 Pin socket point independent complete all as specified and directed.
All as per BOQ item No 2 above, but using 2.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable for phase & 2.5 sqmm PVC insulated unsheathed multistanderd copper conductor cable for earth continuity ( green colour) for one 3 pin socket outlet 15 Amp multi purpose independent controlled by 15 Amp switch, SP, one way, 240 Volts & socket, complete all as specified and directed.
All as per BOQ item No 2 above, but using 4 sqmm (nominal area) for phase and 4 sqmm PVC multistanderd FRLS copper conductor cable for earth continuity ( green colour) for one 15 Amp socket point controlled by 15 Amp switch, SP, one way, 240 Volts & socket, complete all as specified and directed.
S & F in repairs switch piano flush button single pole one way 5 Amps complete all as specified and directed.
S & F in repairs for Buzzer AC 230 Volts singel pole complete all as specified and directed.
S & F in repairs for Bell push flush type 5 Amp complete all as specified and directed.
S & F in repairs socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed
S & F in repairs switch socket outlet 2-in-1, 3 pin 6 A controlled by one switch complete all as specified and directed.
S & F in repairs switch socket combination 5-in-1, 6A/16 A controlled by one switch complete all as specified and directed.
S & F in repairs ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified and directed.
S & F in repairs EME rotary step fan regulator suitable for operation in 230 V, AC, 50 Hz complete all as specified and directed.
S & F in repair Earth plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket 20A, 240 V with and including one MCB SP 20A, 240V complete all as specified and directed.
S&F in repairs 6 to 32 Amp MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed.
S & F in repairs SPN MCB 240 V 50 Hz 10 KA confirming to IS 8828 of rating 40 to 63 Amp complete all as specified and directed.
S & F in repairs TPN MCB 415 V 50 Hz 10 KA confirming to IS 8828 of rating 40 to 100 Amp complete all as specified and directed.
Supply and fix in repair modular switch 1 module 6 amp one way complete all as specified and directed.
Supply and fix in repair modular switch 1 module 16 amp one way complete all as specified and directed.
Supply and fix in repair modular socket 2 module universal type 5/6 amp one way complete all as specified and directed.
Supply and fix in repair modular socket 2 module universal type 15/16 amp one way complete all as specified and directed.
Supply and fix in repair modular bell push with indicator complete all as specified and directed.
M & L for submain wiring with 2 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper concuctor cable, 1100 Volts conforming to IS-694 1990 with ISI mark, drawn through and including PVC casing capping 25 mm size including one run of 6 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth contuinity and connecting up to common earth dolly complete all as specified and directed. Note:- Two runs of 6 Sqmm and one run of 6 Sqmm earth wire will be measured as one running metre
M & L for submain wiring with 4 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper conductor cable, 1100 Volts grade conforming to IS-694 1990 with ISI mark, drawn through PVC casing capping 25 mm size including one run of 6 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth continuity and connecting up to common earth dolly complete all as specified and directed. Note:- Four runs of 6 sqmm cable, one run of 6 sqmm earth wire will be measured as one running metre
S & F MCB SPN distribution board sheet steel, phosphorised powder painted MCB DBs with busbar neutral link, earth bar and DIN rail conforming to IS, 4 way double door, 230 volts, 50 HZ, AC complete all as specified and directed.
All as per BOQ item No 26 above but 8 way double door all as specified and directed
S & F in MCB distribution board TPN, 4 ways, 415 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified.
S&F in repair double door MCCB DB VTPN 4 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, with thimble flame retardant copper conductors and 250 Amps rated bus bar double door open able complete all as specified and directed.
S & F in repair MCCB 4 Pole, thermal release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed.
S & F in repair MCCB 4 pole, thermal release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed.
S & F in repair MCCB 4 pole, thermal magnetic release range 63-80 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, complete all as specified and directed.
S & F in repair LED batten with 20W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten and 20W tube light rod as directed and specified
S & F in repair LED batten with LED tube light 10w 2ft in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc as directed and specified
S & F in repair LED tube rod 20 watt change with existing 36 watt tube rod complete all as specified and directed
Checking of earth resistace and continuity in all married accomodation DBs and all points and checking of voltage differences in between earth and neutral points between phase and neutral /phase and earth also making Register and properly note down the value volts of initial and rectified value and also getting signature from engr-in charge will also includes in the job. NOTE:-checking should be carried out through Digital multi meter of reputed company of ISI marked and will get approved from engr-in-charge before commencing testing and the required sub main wiring and point wiring required for rectification will mesured and paid under relevent item above
Material and labour for enhancement of soil resistivity of earthing by Taking out pit cover and filling salt water through watering pipe of earth pit for improvement of earth resistance complete all as specified and directed
S & F in repair LED building security light fitting with suitable size bracket/angle to fit security light of 45w IP 66 protection complete all as specified and directed
S & F in repair LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protection complete all as specified and directed
S & F in repair LED recess mounted warm white/white 2x2 luminarie 36w fitting complete all as specified and directed
S & F in repair LED 100 watt Highbay luminaire complete fixing arrangement fixed on ceiling with anchor incuding hanging arrangement, connecting up to 3 core multistranded copper conductor complete all as specified and as directed
S & F in repair LED recess mounted Spot light 12W alongwith 12W driver complete all as specified and directed
S & F in repair Meter Box consisting space to fix MCCB as Incomer and 09 nos meter and providing 09 nos MCB RCBO 40 Amps 100 mA, METER box double door fixed type wall mounted CRCA approved FACTROY MADE, 2 mm thick sheet enclousure complete all as specified and directed.The panel should cosists of the following :- INCOMING (1) MCCB 100 AMP 4 P 16 kA thermal magnetic based with o/c, s/c protection & ROH - 01 nos (2) Indicating lamps RYB-03 nos. OUT GOING :(1) 40 amp MCB RCBO 100 mA with enclosure-09 nos. (2) Space for refixing existing electrical meter - 09 nos. NOTE - Contractor should visit the site and to prepare panel as per size required to fit in below stair case complete all as specified and directed
S & F in repair Meter Box consisting space to fix MCCB as Incomer and 7 nos meter and providing 7 nos MCB RCBO 40 Amps 100 mA, METER box double door fixed type wall mounted CRCA approved FACTROY MADE, 2 mm thick sheet enclousure complete all as specified and directed.The panel should cosists of the following :- INCOMING (1) MCCB 100 AMP 4 P 16kA thermal magnetic based with o/c, s/c protection & ROH - 01 nos (2) Indicating lamps RYB - 03 nos. OUT GOING : (1) 40 amp MCB RCBO 100 mA with enclosure - 07 nos. (2) Space for refixing existing electrical meter - 07 nos. NOTE - Contractor should visit the site and to prepare panel as per size required to fit in below stair case complete all as specified and directed
S & F in repair Meter Box consisting space to fix MCCB as Incomer and 05 nos meter and providing 05 nos MCB RCBO 40 Amps 100 mA, METER box double door fixed type wall mounted CRCA approved FACTROY MADE, 2 mm thick sheet enclousure complete all as specified and directed.The panel should cosists of the following :- INCOMING (1) MCCB 63 AMP 4 P 16 kA thermal magnetic based with o/c, s/c protection & ROH - 01 nos (2) Indicating lamps RYB - 03 nos. OUT GOING : (1) 40 amp MCB RCBO 100 mA with enclosure-05 nos. (2) Space for refixing existing electrical meter - 05 nos. NOTE - Contractor should visit the site and to prepare panel as per size required to fit in below stair case complete all as specified and directed
S & F in repair wall light fitting of make havells ct no-LHFHCHE1TL1W020 including 10w LED lamp complete all as specified and directed
Supply and fixing of LED kerb stone of size 500x150x200mm with IP67 LED coated strip with transparent silicon rubber of 3 wattage with the specification given below of 22 LED per strip. The LED strip is inserted in the kerb stone with connecting of Male-Female connector on the ends for interconnecting of the kerb stones. Specification: LED Make : Osram 20,000 working hours, LED Wattage : 3W per kerb stone, LED Volt: 36W, LED Driver : 36W, LED Driver : 36v 10 amp meanwell make (1 Driver for 30 kerb stones) Fixing of LED kerb stone with necessary excavation/Fabrication/Anchor fastners as per site condition with necessary cement concreting and fixing of distribution box with required MCB and connection to the LED power supply and the kerb stones, fixing, excavation,fabrication and anchor fastners prices are deemed to be included in quoted rates by the contractor.
somnath engineering corporation
M.K Enterprises
R A Electric Co.
Radha Engineering Services
BRICKS ON CLOUD INFRA
D.N.PATIL
Modern Engineering Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .