| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.9 L+₹25,860 (0.62%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹41.9 L+₹26,820 (0.64%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹42.5 L+₹87,144.66 (2.09%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹42.9 L+₹1.3 L (3.06%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
21 Dec 2024, 6:00 pmClosed
GE SATWARI
GE SATWARI
SPECIAL REPAIR/REPLACEMENT OF BER SUMMER COOLING APPLIANCES OF MH AND CERTAIN MINOR WORKS AT MIL STN JAMMU
2024_MES_680191_2
GEJM-49/2024-25
Open Tender
Electrical and Maintenance Works
Works
120 days
GE SATWARI
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
GE SATWARI
₹96,400
Yes
4 Jan 2025
30 Nov 2024
23 Dec 2024
30 Nov 2024
21 Dec 2024
7 Dec 2024
Amount
S&F electric water heater, storage type, steel body, vertical type,of capacity 25 litres ,BEE approved 4/5 star rating with steel inner tank and heating element (Incoloy 800 glass coated) upto 2 KW complete with all accessories such as safety valve, thermostate cutout temprature (0ºC to 75ºC), water proof degree IPX4, Class of appliances -Class-I, rated pressure 0.8MPa, NRV, connection pipe etc. including anchor bolt fastners and making good surface as per existing complete all as specified and directed. Make:- Fabia of Havells/HSE-VAS-X of AO Smith/ Crest Plux of Bajaj
Supply, installation, testing & commissioning air cooled , split unit air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 1.5 TR, BEE 5 Star rated with cooling and intelligent heating facility and Digital Inverter twin rotary including its fixing accessories with following specification: (i ) Rated cooling capacity: 18000 Btu/Hr (ii) Rated Current cooling : 7.8 Amp (iii) Rated heating capacity: 18000 Btu/Hr, (iv) Copressor type: High EER twin Rotary (v) Anti dust/Anti-bacterial Filter, (vi) Dehumidifier (vii) Refrigerant gas: R32, (viii) Operation: LCD Remote with self dignosis facility all as specified and directed. Note: The quoted rate shall deemed to include powder coated stand (bracket) for fixing outdoor unit and cutting, chasing of wall/surface and making good as per existing.
Supply, installation, testing & commissioning air cooled , split unit air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 2.0 TR, BEE 3/5 Star rated with cooling and intelligent heating facility and Digital Inverter twin rotary including its fixing accessories with following specification: (i ) Rated cooling capacity: 24000 Btu/Hr (ii) Rated Current cooling : 12.8 Amp (iii) Rated heating capacity: 24000 Btu/Hr, (iv) Copressor type: High EER twin Rotary (v) Anti dust/Anti-bacterial Filter, (vi) Dehumidifier (vii) Refrigerant gas: R32, (viii) noise level -33db (ix) Operation: LCD Remote with self dignosis facility all as specified and directed. Note: The quoted rate shall deemed to include powder coated stand (bracket) for fixing outdoor unit and cutting, chasing of wall/surface and making good as per existing.
Supply and installation, testing and commissioning of refrigerators, electric driven , capacity more than 195 Litres & upto 210 Litres .BEE 5 star rated, suitable for operation on single phase, 240 volt, 50 Hz AC supply complete all as specified and directed .
Supply and installation, testing and commissioning of refrigerators, electric driven , capacity more than 310 Litres & upto to 360 Litres .BEE 5 star rated, suitable for operation on single phase, 240 volt, 50 Hz AC supply complete all as specified and directed .
Supply and installation of desert cooler with steel body having 450mm fan size (heavy duty) with Aluminium blades ISI Marked) electric driven (Single phase) operating switch three step having nominal air flow capacity 4000 CFM with wall thickness of sheet 1 mm and water tank & body pillar 1.5 mm thick sheet including prewired electric control panel with immersed pump of suitable size & capacity (ISI marked) pump and Fan motor including provn of floot valve of suitable size complete all as specified and directed.
M&L for aluminium strip 25mmx3.15mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed
S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed
M&L for test points terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25 mm long hexagonal head screw complete all as specified and directed .
S&F Galvanised iron strip 32 x 6 mm buried in ground complete all as specified and directed .
M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregates) as in supporting foundation of air termination rod complete all as specified and directed .
M & L for complete earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron strip 32×6mm as earthing lead by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion all as specified and directed .
M&L for GI pipe 40 mm dia, light grade for air termination rod fixed with clamps, nuts, bolts complete all as specified and directed .
Taking down chowkats or frames with shutter without taking off shutter from the frame exc 1.5 sqm & n. exe 4 sqm each including cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed .
S&F powder coated (Radiation lead line door) galvanised steel metal door frame and shutter, door frame of hollow section 105mmx57mm having thickness not less than 1.6 mm and thickness of powder coated metal 1.20mm for door shutter & overall door thickness 46 mm. Hollow portion of door filled with rock wool/honeycomb and 2mm lead sheet in middle of the door complete all as specified and directed . Note : The radiation door shall be made from authorised manufacturers.The contractor shall submit the company profile & get it approved from GE before purchasing .
S&F heavy duty stainless steel two ball bearing hinge of size 4"x3"x3mm, flat button, fixed with machine screws complete all as specified and directed
S&F anchor fastner CSK head type with GI plating size: 8mm x 80 mm with PVC sleeve (for door frame fixing in wall) fixed with gitties complete all as specified and directed
S&F heavy duty steel overhead rack and pinion door closer with adjustable closing speed and adjustable latching action with mounting plate complete all as specified and directed
S&F heavy duty mortise dead lock with 70 mm cyllinder complete all as specified and directed
S&F heavy duty stainless steel 'D' shape handle, 19 x 250 mm complete all as specified and directed
S&F lead line fix window powder coated galvanised steel metal frame of hollow section 105mmx57mm & thicknes not less than 1.6 mm and lead glass thickness 10 mm, type ZF3, refracton index 1.7172, Density 4.46, Lead equivalent 3.10, Light Transmittane >85%, PB%-61.03% and X Ray Peak Voltage (KV) -150 complete all as specified and directed. Note : The radiation window shall be made from authorised manufacturers.The contractor shall submit the company profile & get it approved from GE before purchasing
Taking down cement plaster from brick walls /ceiling or concerete of any description, raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material outside the premises complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on brick/stone work and surface finished even and smooth without using extra cement complete all as specified and directed .
M&L for preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over two coats of wall care putty of 1 to 2 mm thick each over one coat of primer complete all as specified and directed.
SATISH AND CO (BID ID -3188996)
Harsh Electricals (BID ID -3188003)
Azurite Engineering (BID ID -3189345)
M/S S K Electricals Regd (BID ID -3191312)
kailu construction co (BID ID -3188854)
CELMAC REGD (BID ID -3189180)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .