Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | Rejected-Technical Not enlisted in required Category |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
27 Jul 2020, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
OUTSOURCING OF HT INSTALLATION AT STF AREA CVRDE AVADI
2020_MES_357567_1
8306/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RDA AVADI
₹15,000
Yes
16 Aug 2020
2 Jul 2020
29 Jul 2020
2 Jul 2020
27 Jul 2020
14 Jul 2020
2 Jul 2020 - 14 Jul 2020
Amount
Outsourcing services of 11KV HT installations of Transformer/ HT VCB Panels/LT Panels and attending day to day maintenance and breakdown including holidays, sundays by employing one electrician(skilled) per shift in two shift per day, with shift time 06.00hrs to 14.00hrs and 14.00hrs to 22.00hrs for the installation consisting the following switchgers at Residential area CVRDE Avadi:- (a) 11KV VCB Panel Indoor 13.KA 800A- 7Nos, Transformer 1500 & 2000KVA-1No,VRLA battery bank&charger Panel at STF area (b) DG Set 380KVA at STF area (c) 11KV VCB Panel Indoor 13.KA 800A- 6Nos, Transformer 1000 VRLA battery bank&charger Panel, at EMI area. (i) The rate quoted by the contractor shall deemed to minimum wages as per Min of Labour & Employment in Cat "A Area" in construction or Maintenance employment included all statuary as applicable such as all taxes as applicable including GST, EPF, ESIC, Bonus, Labour welfare cess and anticipiated effect due to increase in wages during the contract period etc. (ii) In case the rates quoted by tenderrer are less than the rate mentioned as per latest wages act issued by GOI, his tender will be treated as non- bonafied and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongest valid/bonafide bids only
Supply First aid box with standard medicines complete all as specifed and directed.
Supply 4KG capacity ABC Type Fire Extinguisher dry powder type wall mounted type suitable for electrical started fire applications with standard specifications ans accessories ISI marked complete all as specifed and directed.
Item No 1: Note 1: (a) Routine check/attending breakdown of VCB Panel/Transformer (b) Switching on/off streetlights on all days at Technical area .(c) The quoted rate is deemed to include for all surrounding premises cleaning such as inside & out side the installationss including cutting of grass shurbs etc upto 5mtr distance from installation building and always keep ready position. The cleaning/cutting aids shall be provided by the contractor for the installations. whenever is required.(d) Maintenance of HT Installation log sheets and shutdown register.(e)The rates quoted by the tenderer shall be deemed accident insurance of the working persons during working hours. (f) The contractor should procure all the safety equipments what ever is required for smooth operation and maintanance works for operator. The equipments includes Electricians Hand gloves,Torch light, Safety belts, Helmets,ear pads, Earth discharge rods, cotton waste for cleaning etc. and to be kept with sub station. (g) The contractor should maintain proper daily log sheets for each installation duly printed and binded as per given format for operation of electric supply and binded monthly basis and submitted to JE/AGE E/M all as directed.(h) The contractor should kept all the measuring instruments what ever is required for testing and maintenance works for electrician. (j)The equipments includes test lamps, Tong tester, Multi meter, Earth testers, LT/HT Meggers,etc. and to be kept with Sub station.
(k)Tenderer should observe the minimum wages Act of local State Govt/Central Govt. (l) It is the responsibility of Conrtactor to ensure that attendance register is maintained duly signed kept on record and payment of tradesman for the no of days present will only be made.In case the person not found on duty for a day or part there of due to any reason what so ever, Rs 1000/- for each shift will be recovered. (m) Rate inclusive for fixing/shiting of fire extinguiser/first aid/ notice board/fire order/standing order etc inside HT Installation(n) M&O staff will wear uniform of Black Pant and Light Grey Shirt provided by contractor during duty hours as approved by Engr in Charge.
(o) Diesel issued under Schedule 'B' for free for supply. Rate quoted includes the cost of Transportation of Diesel issued by the department within the CVRDE Area (p) Routine check of Engine/Alternator the daily . (q) Maint of batteries and apply of petrolium jelly and topping up of distilled water. (r) Daily cleaning of DG set complete and area cleaning all around the DG set includes cutting of vegetation, grass etc. (s) Replace minor parts Indication lamps, push button, bolt, nuts etc etc (u) Check belt tension regularly (v) Check cooling fan, radiator water level, hoses.(w) Check lub oil level, coolant levels regularly. (x) Maintenance of log sheet. (y) Checking of battery voltage regularly and battery charging unit.Whenever any visiting officer visits, the site must be clean in all respect. In case any bad/adverse remarks given by any visiting officer at any time, the necessary recovery for rectification of the same will be deducted from the contractorar as certified by Engr-in -charge and no claim whatsoever is admissible on the account. AGE(I) R&D AVADI 's decision is final
Item No1: Note 2: i: Wages for all workers employed shall be paid before 7th day of every month through aadhar linked bank account without fail irrespective of whether RAR / FB is claimed or not. ii: ‘NIL or Zero’ Quoting against OH & Profit shall be render the bids as ‘non-bonafide’. iii: Contractor is required to quote upto two digit after decimal place or otherwise it will be considered by rounding off to two digits after decimal place. iv: In case of tie amongst bidders, following criteria shall be applied to decide the lowest bidder for acceptance:- (aa) When tie is amongst MES enlisted firms, order of acceptance shall be as given below:- (i) Bidder of highest class will be considered for acceptance. (bb) In MES in case of tie between two or more same class bidder. (i) Highest class bidders having average marks in the performance reports stage II of last 5 completed works. (Contractor to be submitted Affidavit, Work Order, Completion Certificate as & when required) (ii) Bidder having highest amount of working capital (cc) When tie involves unlisted firm also:- (i) Bidder having highest amount of working capital.
M/s GM Constructions
BKR Enterprises
KRISHNA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .